5.2.3.
Fitting the lock into the housing
The jumper next to the connector on the lock needs
to be positioned for fail safe or fail secure
configuration as per the directions on the lock cover.
The 7-way wire loom should be attached to the
wiring protruding from the housing and plugged into
the lock. The lock should then be slid into the
housing and secured in place with the supplied M5
machine screws. Make sure that the wiring integrity
is maintained as the lock is screwed in place.
5.2.4. Fitting the strike plate housing to glass
For simple application to glass the YD30M housing
is supplied with self-adhesive tape. With the
backing removed the housing can be applied
directly to the glass. A flat stainless steel dress plate
is fitted on the opposite side of the glass to give a
clean finish. The protective coating on the dress
plate can be removed once it is in place.
5.2.5. Fitting the strike plate into the housing
The strike plate is placed into the housing and
secured in place with the supplied M5 machine
screws.
5.2.6. Checking the operation
With the lock and strike installed and wiring
complete the door is closed to check the alignment
and operation. The key area for alignment is the bolt
pin; the pin is designed to touch the leading edge of
the strike plate hole to pull the door in, but it cannot
be allowed to touch the sides of the hole as this will
limit its unlocking ability. If its rubs or touches the
side of the strike plate hole, either the lock or strike
plate needs to be re-positioned.