Specifications 

Output protocols 

Wiegand 26-199bit, RS485 or custom configuration (Model 

dependent) 

Power requirement 

7-18V DC 

Current 

consumption 

79mA (Idle) 

250mA (Peak) 

Read range 

20-40mm (0.8”-1.6”) at 12V DC depends on the type of card 

used 

Relay Rating 

80mA 

Operating 

temperature 

-10’C to +50’C (14’F to 122’F) 

Relative humidity 

90% max, operating non-condensing 

Reader dimensions 

190mm(L) x 98mm(W) x 40mm(D) (7.48”x3.86”x1.57”) 

Status LED 

Green & Red 

Audible tone 

Internal and external buzzer control 

Keypad 

3 x 4 Keypad and 4 Function keys, illuminated 

Colour finish 

Charcoal 

IP rating 

IP65 

 

Wiring diagram 

 

Note: 

 

A shielded cable is recommended to be used. The shield is connected to controller 0V reference 

 

Maximum wiegand data cable length: 150 meters (500 feet)  

 

Buzzer and LED are low activated. 

 

RS485 and Relay are only for optional use.  

 

Terminate or insulate all un-used wires 

 

Regulatory Information 

C-Tick: This device is C-Tick complied.  

 

CE: The device has passed all relevant tests and obtained CE approval. 

 

FCC: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device 
may not cause interference and 2) this device must accept any interference, including interference that may cause 
undesired operation of the device.  
Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 
15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential 
installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to 
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try 
to correct the interference by one or more of the following measures: 
-Reorient or relocate the receiving antenna. 
-Increase the separation between the equipment and receiver. 
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
-Consult the dealer or an experienced radio/TV technician for help.

 

Any changes or modifications not expressively approved by BQT Solutions could void the user’s authority to operate this 
equipment. 

 

Information obtained in this document is subject to change without notice. 

For further technical information, visit our website at www.bqtsolutions.com or email 

[email protected]

Alternatively contact us at one of our global locations 

 

AUSTRALIA & PACIFIC 

BQT Solutions (Australia) Pty Limited 

Unit 29, 1 Talavera Road 

North Ryde, NSW 2113, Australia 

Phone: +61 (0)2 8817 2800 

Fax: +61 (0)2 8817 2811 

Email: [email protected] 

 

 

EUROPE AND MIDDLE EAST 

BQT Solutions (UK) Limited 

Regus, Castle Court, 41 London Road 

Reigate, RH2 9RJ 

United Kingdom 

Phone: +44 (0)17 3773 5071 

Fax: +44 (0)17 3773 5072 

Email: [email protected] 

 

GREATER ASIA 

BQT Solutions Singapore Office 

Mediapolis 

71 Ayer Rajah Crescent #03-03 

Singapore 139951 

Phone: +65 6220 7970 

Fax: +65 6220 7656 

Email:  [email protected] 

 

 

 

 

Wire connection 
Note
:  

Power to the unit is provided from the listed control unit or from a 

separately UL listed 12V DC power-limited, access control power source. 

DO NOT supply power during installation. 

 

Wiring methods shall be in accordance with the Electrical wiring regulation 

in your country / region. 

 

Check your circuit diagram for the colour coding of the circuit wiring. The 

device can be damaged beyond repair if the wiring is connected incorrectly. 

This will void the warranty.

 

 

1.

 

Connect the 0V wire to the power 0V line; 

Note

: The 0V line of all power supplies must be connected to a common 0V reference 

point. 

2.

 

Connect the Wiegand data wires; 

3.

 

Connect the Buzzer and LED wires; 

4.

 

Connect 12V DC wire; 

5.

 

Place unit on the wall (Make sure the wires are not crushed. This will 

void the warranty if damage occurs) 

6.

 

Insert and hand tighten the screws; 

7.

 

Check that the unit is level before tightening the screws; 

Note

: Excessive tightening of screws may deform the casing, resulting in a damaged 

unit. This will void the warranty. 

8.

 

Turn on the 12V DC power to power up the device.  

9.

 

Allow 5 – 10 seconds for the device to finish initialization (depends on 

the application). Make sure the unit is functioning correctly according 

to the application specification. 

 

External Use 

 

Make sure the wire bundle to the device has an IP rating of at least IP65 

 
Handling 

 

Handle the device with care. DO NOT damage or drop unit before 
installation. This will void the warranty. 

 

If the case is damaged, the unit may not be to the specified IP rating. 
Replace the unit if the case is damaged. 

 
Maintenance 

 

Once installed the device requires no maintenance. 

 

Warranty 

Unless specified otherwise, the Company warrants to the Customer that’ BQT Solutions 
Branded Products’ (excluding third party products and software) are covered by a 
return to base warranty on defects in materials and workmanship affecting normal use 
for a period of the Warranty offered under the Standard Terms and Conditions of Sale 
from BQT invoice date (‘Standard Warranty’) 
 
This standard warranty does not cover damage, fault, failure or malfunction due to 
external causes including; accident, misuse, problems with electrical power, servicing 
not authorised by the Company,  usage and/or storage and/or installation not in 
accordance with Product instructions, failure to perform required preventative 
maintenance, normal wear and tear, act of God, fire, flood, war, any violent or similar 
occurrence; any attempt by any person other than Company personnel or any person 
authorised by the Company  to repair or support the Products and problems caused by 
use of parts and components not supplied by the Company.  The standard warranty 
does not cover any items that are in one or more of the following categories: software; 
external devices; accessories or parts added to the product after the product has been 
shipped from BQT Solutions.  
 
During the warranty, period beginning on the invoice date, the Company will repair or 
replace faulty products (at its absolute discretion) returned to its’ factory. The Customer 
must prepay shipping and transportation costs and insure the shipment or accept the 
risk of loss or damage during such transportation. 
 
The Customer shall be solely responsible for determining suitability for use and the 
Company will, in no event, be liable in this respect. This standard warranty is given in 
place of all warranties, conditions, terms, undertakings and obligations implied by 
statute, common law, trade usage, and course of dealing or otherwise including 
warranties or conditions of merchantability, fitness for purpose, satisfactory quality and 
/ or compliance with description, all of which are hereby excluded to the fullest extent 
permitted by law. 
 
 
 

Copyright © 2014 BQT Solutions Limited. BQT Solutions and the BQT solutions logo are registered trademarks of BQT Solutions (Australia) Pty Ltd. 

 

Отзывы: