background image

Tel 01442 230 800   www.bpt.co.uk

Tel 01442 230 800   www.bpt.co.uk

9

10

How to program a one button

analogue call panel

How to program multiple 

analogue call buttons

Make a call into the Entry Panel.
Once the panel answers, enter 

46

 followed by the panel’s serial number (found on a 

white label on the back of the main printed circuit board) to enter into programming. 
E.G: 

46 then 510444

You will now hear the Integrated Digital Assistant (IDA), so follow these voice options:

Make a call into the Entry Panel.
Once the panel answers, enter 

46

 followed by the panel’s serial number (found on a 

white label on the back of the main printed circuit board) to enter into programming. 
E.G: 

46 then 510444

You will now hear the Integrated Digital Assistant (IDA), so follow these voice options:

THEN

THEN

THEN

THEN

THEN

THEN

OR

OR: Enter the 3rd, 4th, 5th, 6th & 
7th call forwarding telephone 
numbers if required.

OR: Enter the 3rd, 
4th, 5th, 6th & 7th call 
forwarding telephone 
numbers if required.

In the Main Menu:

 “Enter ‘1’ then ‘STAR’ (   )

to set telephone numbers.”

*  

In the Main Menu:

 “Enter ‘1’ then ‘STAR’ (   )

to set telephone numbers.”

*  

“Enter the first phone number followed by 

‘STAR’ (   ) or press ‘STAR’ (   ) now to keep: 

‘01442 230800’.”

(Programmed from factory with the bpt support line)

*  

*  

“Enter the first phone number followed by 

‘STAR’ (   ) or press ‘STAR’ (   ) now to keep: 

‘01442 230800’.”

(Programmed from factory with the bpt support line)

*  

*  

*  

“Enter the call button number to be 

configured followed by ‘STAR’ (   ).”

(EG: Call button number 1)

*  

“Enter the call button number to be 

configured followed by ‘STAR’ (   ).”

(EG: Call button number 1)

*  

*  

“Enter the calling time in seconds followed 

by ‘STAR’ (   ) or press ‘STAR’ (   ) now to 

keep the default 30 seconds”

*  

*  

“Enter the calling time in seconds followed 

by ‘STAR’ (   ) or press ‘STAR’ (   ) now to 

keep the default 30 seconds”

*  

*  

“Enter the calling time in seconds followed 

by ‘STAR’ (   ) or press ‘STAR’ (   ) now to 

keep the default 30 seconds”

*  

*  

“Enter the calling time in seconds followed 

by ‘STAR’ (   ) or press ‘STAR’ (   ) now to 

keep the default 30 seconds”

*  

“Enter ‘0’ then ‘STAR’ (   ) to end configuration.”

*  

“Enter ‘0’ then ‘STAR’ (   ) to end configuration.”

“Enter the second phone number 

followed by ‘STAR’ (   ) ."  

(If this is not required press ‘STAR’ to move on     )

*  

“Enter the second phone number 

followed by ‘STAR’ (   ) ."  

(If this is not required press ‘STAR’ to move on     )

*  

“Enter the next call button number to be 

configured followed by ‘STAR’ (   ) ."  

(EG: Call button number 2)

*  

GSMVRA / LANDVRA

GSMVRA / LANDVRA

GSMVRA/

1-24 call buttons

or

LANDVRA/

1-24 call buttons

GSMVRA/

1-24 call buttons

or

LANDVRA/

1-24 call buttons

Содержание GSMVRA/1-24

Страница 1: ...NDVRAK 1 24 GSM Landline Entry Panels Notes Entry Panel Phone Number Entry Panel Serial Number Installation Instructions For Firmware Version 0 2 Unit 16 Sovereign Park Cleveland Way Hemel Hempstead Herts HP2 7DA T 01442 230 800 F 01442 244 729 E sales bpt co uk W www bpt co uk Installation Instructions For Firmware Version 0 2 December 2011 ...

Страница 2: ...seconds 3 Once the call is answered full communication between the Entry Panel and the telephone receiver commences for a maximum timed period of up to one minute talk time This time period is not adjustable 4 To activate the timed door release relay 1 during communication with the Entry Panel the user must enter 1 then or simply on it s own The relay release time can be set between 1 second and 2...

Страница 3: ...twork as per standard service provider requirements have calling credit available and its number known A Pay As You Go or Contract SIM can be used 4 There needs to be a 230V AC mains supply nearby the entry panel location to connect the Power Supply Unit provided by bpt UK 5 The correct 12V DC 1A regulated PSU which is provided MUST be installed to power the panel and should not be used to power a...

Страница 4: ...elay On Audio volume and Relay pulse time adjustments AUDIO VOLUME RELAY PULSE GSM LANDLINE PSTN Both relay times can be set between 1 256 seconds To adjust simply insert a small flat screwdriver and rotate the potentiometer slowly and gently to set the required time Speaker Volume Up Down Adjust only if required as this is factory set for most environments To adjust you must first enter into the ...

Страница 5: ...Call 13 C1 R4 Call 14 C2 R4 Call 15 C3 R4 Call 16 C4 R4 Call 17 C1 R5 Call 18 C2 R5 Call 19 C3 R5 Call 20 C4 R5 Call 21 C1 R6 Call 22 C2 R6 Call 23 C3 R6 Call 24 C4 R6 24 call buttons expansion board Main Board GSM example shown MULTI CALL COMPONENTS CONNECTING ANALOGUE PSTN Coded Access keypad board with 7 call button inputs Coded access keypad Entry Panel components Single call button GSM exampl...

Страница 6: ...followed by STAR or press STAR now to keep 01442 230800 Programmed from factory with the bpt support line Enter the first phone number followed by STAR or press STAR now to keep 01442 230800 Programmed from factory with the bpt support line Enter the call button number to be configured followed by STAR EG Call button number 1 Enter the call button number to be configured followed by STAR EG Call b...

Страница 7: ...follow these voice options THEN THEN THEN OR Enter the 3rd 4th 5th 6th 7th call forwarding telephone numbers if required In the Main Menu Enter 1 then STAR to set telephone numbers Enter the first phone number followed by STAR or press STAR now to keep 01442 230800 Programmed from factory with the bpt support line Enter the call button number to be configured followed by STAR EG Call button number...

Страница 8: ... the panel s serial number found on a white label on the back of the main printed circuit board to enter into programming E G 46 then 510444 You will now hear the Integrated Digital Assistant IDA so follow these voice options THEN THEN THEN OR OR Enter the 3rd 4th 5th 6th 7th call forwarding telephone numbers if required In the Main Menu Enter 1 then STAR to set telephone numbers Enter the first p...

Страница 9: ...om Relay 2 menu Enter 0 then STAR to exit configuration OR select another option from Relay 1 menu Using the Entry Panel s Keypad enter 46 followed by the panel s serial number or Make a call into the entry panel and once it answers enter 46 followed by the panel s serial number found on a white label on the back of the main printed circuit board to enter into programming E G 46 then 510444 You wi...

Страница 10: ... STAR to exit configuration OR select another option the Menu Using the Entry Panel s Keypad enter 46 followed by the panel s serial number or Make a call into the entry panel and once it answers enter 46 followed by the panel s serial number found on a white label on the back of the main printed circuit board to enter into programming E G 46 then 510444 You will now hear the Integrated Digital As...

Отзывы: