background image

Power supply with plug for connection to the electrical mains and cable with connector for the video receiver connection.

6

J3

CN2

CN1

J1
J2

5

3

4

2 1

3

4

2 1

4

TERMINAL BOARDS

CN1-

CN2

1

AUDIO   (Red)

2

GND       (Blue)

3

V+          (Yellow)

4

VIDEO    (White)

5

+

POWER     (Red)

6

POWER GND  (Black)

CN1 

Connected with Entry Panel 1

CN2 

Connected with Entry Panel 2

J3

J1

J2

J3

J1

J2

J3

J1

J2

D

JUMPER

J3 (Back light compensation for entry panel call button): 

The default setting is with J3 jumper connected. Remove the jumper if the 
entry panel button back light is not needed.

J1 (Ringing output): 

It is normally supplied inserted. When a call from entry panel to indoor 
phone is performed the outdoor panel can also hear the call ring. Remove 
jumper J1 to avoid that.

J2 (Video signal compensation): 

It is normally supplied inserted. When there are more than one internal 
receiver, level J2 jumper connected to the furthest one to assure the video 
signal transmission. Remove J2 from the other receivers (see figure 4).

VPSK01 SA

TECHNICAL FEATURES

Main supply

100-240 VAC, 50-60 Hz, 0,4 A

Nominal power supply

14,5  VDC, 1,3 A

Dimensions

105x58x32 mm

Operating temperature

0 °C +40 °C

Содержание b-view VRS01 SA

Страница 1: ...16 07 2012 Installation Manual VRS01 SA ...

Страница 2: ...s and the ends of the wires to prevent malfunctions caused by wire oxidation When installation is completed always check for correct operation of the unit and the system as a whole Before performing any cleaning or maintenance operation disconnect the power supply to the device In the case of device failure or malfunction disconnect it from the power supply and do not tamper with it Should the uni...

Страница 3: ...he location where the unit has to be mounted Use the bracket to mark the location point accurately Drill the holes and use the screw anchors to fill them Fasten the metallic support to the wall using the provided screws and observing the UP indica tion figure 1 According to the wiring diagram perform the wiring connections Mount the unit to the bracket figure 2 180 128 24 3 ANCHORS BRACKET HOOKS H...

Страница 4: ...ected Remove the jumper if the entry panel button back light is not needed J1 Ringing output It is normally supplied inserted When a call from entry panel to indoor phone is performed the outdoor panel can also hear the call ring Remove jumper J1 to avoid that J2 Video signal compensation It is normally supplied inserted When there are more than one internal receiver level J2 jumper connected to t...

Страница 5: ...C included Power supply adaptor AC DC included Door Lock Door Lock Power Supply for lock Power Supply for lock Entry Panel 2 Entry Panel 1 Both twisted or untwisted cables are allowed Distance Wire La 28 m 0 2 mm2 La 50 m 0 3 mm2 La 70 m 0 5 mm2 CONNECTION EXAMPLES Maximum extension system DISTANCES 5 ...

Страница 6: ...1 1 2 3 4 CN2 1 2 3 4 J3 J1 J2 CN1 1 2 3 4 CN2 1 2 3 4 J3 J1 J2 1 AUDIO 2 GND 3 V 4 VIDEO 5 5 N L N L 220 V 50Hz 5 6 5 6 5 6 1 AUDIO 2 GND 3 V 4 VIDEO 5 5 VRK01 SA VEPK01 SA VEPK01 SA VRK01 SA VRK01 SA VRK01 SA Power Supply for Lock Power Supply for Lock 220 V 50Hz 220 V 50Hz 220 V 50Hz 6 ...

Страница 7: ...7 ...

Страница 8: ...end of its life cycle take measures to ensure it is not discarded in the environment The equipment must be disposed of in compliance with the regulations in force recycling its component parts wherever possible Components that qualify as recyclable waste feature the relevant symbol and the material s abbreviation Imported by TRI BPT Automation Pty Ltd http www bpt sa co za e mail info bpt sa co za...

Отзывы: