Targha 200
TAR
GHA 200
8
5 21 8 11 12 14
2
1
3
6
5
4
7
8
9
0
SW1
I1
NO
NC
C2
NO
NC
C1
M1
M2
Adjustments
Loudspeaker audio
Microphone audio
TERMINAL BOARDS
5
–
12 VDC
21 +
Supply voltage
8
Common call (for witness note)
11
Audio to receiver
12
Audio from receiver
14
Enabling
NOTE. In installations which do not cater for the ena-
bling control, terminal 14 can be connected to the
earth (module always on) or terminal 12 (module on
only when receiver is lifted).
TERMINAL BOARDS
M1
12 to 16V AC, 14 to 18V DC
module power supply
I1
input
external
contact
–
ground
M2
C1
common
contacts
relay 1
NC
normally closed
NO
normally open
C2
common
contacts
relay 2
NC
normally closed
NO
normally open
HA/200
HNA/102
TECHNICAL FEATURES
Power supply
12 VDC
Absorption
50 mA max (<35 stand-by)
Storage temperature
-25 °C +70 °C
Operating temperature -15 °C +50 °C
IP Degree
IP 54
TECHNICAL FEATURES
Power supply
12 ÷16 VAC, 14÷18
VDC
Approximate current de-
mand with AC power supply
max. 260 mA
(120 mA stand-by)
Approximate current de-
mand with DC power supply
max. 180 mA
(80 mA stand-by)
Working temperature range -20 °C +50 °C
TERMINAL FUNCTION
SW1
On:
LEDs activated to light call buttons.
Off:
LEDs are disabled (default setting).
HNA/102
A B C
Function
÷
buttons for entering numerical codes
and for programming
button for activating an alarm or bell
button for locking relays in active state
A (green)
B (yellow)
C (green)
three LEDs indicating status of module
and functions in progress
OPERATING CHARACTERISTICS
a)
Up to 100 user codes can be stored. Codes can be
3, 4 or 5 digits long, with values in the range 001 to
65535. Each code can be associated with one of the
2 relays.
b)
The module features 2 relays for facilities with the
following operating features:
- programmable activation time for each relay (in the
range 1 to 65 s);
- monostable or bistable mode for each relay;
- option of locking relays in active state in monostable
mode by pressing key before the activation time is
up (to disable, enter the code again);
- option of associating relay 2 with an alarm or bell acti-
vation facility (function 09 must be enabled first).
Activating the alarm:
the relay 2 is activated by pres-
sing key
before entering your user code (see fun-
ction 10 for disabling instructions).
All user codes associated with relay 1 are enabled
when the alarm is activated.
Activating the bell:
the relay 2 is activated by simply
pressing key
once.
To prevent false alarms being sent, the option of asso-
ciating usercodes with relay 2 is automatically inhibited.
c)
When a key is pressed, an audible signal is issued
to confirm the various programming stages etc. as
follows:
- key pressed
= short buzz;
- correct operation
= long buzz;
- incorrect operation
= three short buzzes.
d)
LEDs indicate the status of the module and fun-
ctions in progress:
- green LED A,
suitably programmed, it can be:
- an indicator associated with the audible signal,
- disabled,
- controlled by input I1.
- yellow LED B,
pulse =
confirms facilities activated.
- green LED C,
always lit =
in service,
flashing =
in programming mode.
The LED lights 1 min after the unit has been powered
(during which time, the unit can be reset).
e)
The keypad can be disabled indefinitely by entering
a specific code, e.g. when you are away for some time
(see
FUNCTION 12
).
f)
The keypad is locked out for a programmable time
if, after entering 20 digits, no valid code has been ente-
red (see
FUNCTION 07
).
g)
There is an input I1 for electric contact, which can be
programmed to give it different functions:
activates relay 1, enables tradesman mode, or controls
green LED A (see
FUNCTION 11
).
h)
Tradesman mode: via this function, you can enable
relay 1 only when contact I1 is closed to earth (with
external timer) and only for user codes associated with
facility 3 (see
FUNCTION 03
).
i)
Default settings can be restored using the RESET fun-
ction (see resetting procedure).
Stored user codes and the number of digits program-
med are kept in the memory.
THE HNA/102 MODULE’S DEFAULT FACTORY
SETTINGS
PROGRAMMING CODE:
1234
(5 digits).
RESET CODE:
12
not programmable;
USER CODE on relay 1:
258
.
USER CODE on relay 2:
36
.
ACTIVATION TIME for relays activating facilities:
5 s.
ACTIVATION MODE for relays activating facilities:
monostable.
NUMBER OF DIGITS for user codes:
4.
Keypad LOCKOUT TIME:
10 s.
BELL:
disabled.
BELL TIME:
3 s.
ALARM:
disabled.
KEYPAD:
enabled.
INPUT FOR CONTACT I1:
controlled by relay 1.
GREEN LED A:
disabled.
Содержание AG2K200C03UK
Страница 1: ...Installation Manual AGATAKIT C 200 UK AGATA P1 A 200N TARGHA 200 24806770 07 05 2013 ...
Страница 10: ...10 ...