background image

Targha 200

TAR
GHA 200

8

5 21 8 11 12 14

2

1

3
6

5

4

7

8

9

0

SW1

I1

NO

NC

C2

NO

NC

C1

M1

M2

Adjustments

Loudspeaker audio

Microphone audio

TERMINAL BOARDS

5

   12 VDC

21 +

    Supply voltage

8

Common call (for witness note)

11

Audio to receiver

12

Audio from receiver

14

Enabling

NOTE. In installations which do not cater for the ena-
bling control, terminal 14 can be connected to the 
earth (module always on) or terminal 12 (module on 
only when receiver is lifted).

TERMINAL BOARDS

M1

12 to 16V AC, 14 to 18V DC
module power supply

I1

input

external
contact

ground

M2

C1

common

contacts
relay 1

NC

normally closed

NO

normally open

C2

common

contacts
relay 2

NC

normally closed

NO

normally open

HA/200

HNA/102

TECHNICAL FEATURES

Power supply

12 VDC

Absorption

50 mA max (<35 stand-by)

Storage temperature

-25 °C +70 °C

Operating temperature -15 °C +50 °C
IP Degree

IP 54

TECHNICAL FEATURES

Power supply

12 ÷16 VAC, 14÷18 
VDC

Approximate current de-
mand with AC power supply

max. 260 mA 
(120 mA stand-by)

Approximate current de-
mand with DC power supply

max. 180 mA 
(80 mA stand-by)

Working temperature range -20 °C +50 °C

TERMINAL FUNCTION

SW1

On: 

LEDs activated to light call buttons.

Off: 

LEDs are disabled (default setting).

HNA/102

 A   B  C

Function

÷

buttons for entering numerical codes 
and for programming
button for activating an alarm or bell
button for locking relays in active state

A (green)
B (yellow)
C (green)

three LEDs indicating status of module 
and functions in progress

OPERATING CHARACTERISTICS

a) 

Up to 100 user codes can be stored. Codes can be 

3, 4 or 5 digits long, with values in the range 001 to 
65535. Each code can be associated with one of the 
2 relays.

b) 

The module features 2 relays for facilities with the 

following operating features:
- programmable activation time for each relay (in the 
range 1 to 65 s);
- monostable or bistable mode for each relay;
- option of locking relays in active state in monostable 
mode by pressing key   before the activation time is 
up (to disable, enter the code again);
- option of associating relay 2 with an alarm or bell acti-
vation facility (function 09 must be enabled first).

Activating the alarm:

 the relay 2 is activated by pres-

sing key 

 

before entering your user code (see fun-

ction 10 for disabling instructions).
All user codes associated with relay 1 are enabled 
when the alarm is activated.

Activating the bell:

 the relay 2 is activated by simply 

pressing key 

 

once.

To prevent false alarms being sent, the option of asso-
ciating usercodes with relay 2 is automatically inhibited.

c) 

When a key is pressed, an audible signal is issued 

to confirm the various programming stages etc. as 
follows:

- key pressed

 = short buzz;

- correct operation

 = long buzz;

- incorrect operation 

= three short buzzes.

d)

 LEDs indicate the status of the module and fun-

ctions in progress:

- green LED A,

 suitably programmed, it can be:

- an indicator associated with the audible signal,
- disabled,
- controlled by input I1.

- yellow LED B,

pulse =

 confirms facilities activated.

- green LED C,

always lit =

 in service,

flashing = 

in programming mode.

The LED lights 1 min after the unit has been powered 
(during which time, the unit can be reset).

e) 

The keypad can be disabled indefinitely by entering 

a specific code, e.g. when you are away for some time 
(see 

FUNCTION 12

).

f) 

The keypad is locked out for a programmable time 

if, after entering 20 digits, no valid code has been ente-
red (see 

FUNCTION 07

).

g) 

There is an input I1 for electric contact, which can be 

programmed to give it different functions:
activates relay 1, enables tradesman mode, or controls 
green LED A (see 

FUNCTION 11

).

h)

 Tradesman mode: via this function, you can enable 

relay 1 only when contact I1 is closed to earth (with 
external timer) and only for user codes associated with 
facility 3 (see 

FUNCTION 03

).

i) 

Default settings can be restored using the RESET fun-

ction (see resetting procedure).
Stored user codes and the number of digits program-
med are kept in the memory.

THE HNA/102 MODULE’S DEFAULT FACTORY 

SETTINGS

PROGRAMMING CODE:

 

1234

 (5 digits).

RESET CODE:

 

 12

 not programmable;

USER CODE on relay 1:

 

258

.

USER CODE on relay 2:

 

36

.

ACTIVATION TIME for relays activating facilities:

 5 s.

ACTIVATION MODE for relays activating facilities:

 

monostable.

NUMBER OF DIGITS for user codes:

 4.

Keypad LOCKOUT TIME:

 10 s.

BELL:

 disabled.

BELL TIME:

 3 s.

ALARM:

 disabled.

KEYPAD:

 enabled.

INPUT FOR CONTACT I1:

 controlled by relay 1.

GREEN LED A:

 disabled.

Содержание AG2K200C03UK

Страница 1: ...Installation Manual AGATAKIT C 200 UK AGATA P1 A 200N TARGHA 200 24806770 07 05 2013 ...

Страница 2: ...2 AGATA P1 HA 200 A 200R HBP HPC 1 AGK200C03UK HPC 2 AG2K200C03UK HPC 3 AG3K200C03UK HPC 1 HNA AGK200C03HNA ...

Страница 3: ...h the shell to the bottom of the device fig 4 AGATA P1 2 1 4 3 Ø60 503 Terminal boards M1 5 Ground 7 Call input from entry panel 8 Audio FROM entry panel 9 Audio TO entry panel 5 7 8 9 M1 BP1 P1 BP1 In order to make the door open but ton active only when the reciever is up cut the BP1 wire link P1 Optional AGATA P1 auxiliary function switch housing Door lock release Auxiliary 2 w Only use soft dry...

Страница 4: ...ontrolled interval adjustable from 2 to 15 seconds by means of poten tiometer P1 figure 3 Call generator 2 types of two tone call up to 3 internal units can be connected in parallel to the same call The unit can be powered from a 12 V DC power supply e g battery or uninterruptable power supply terminals B and 5 The unit has no battery protection A 5 8 B 5 21 8 8A 11 12 23 16 NO C NC 9 B C P1 TERMI...

Страница 5: ...s Hole plugs Cable guide joints Cable guide joint Spacer Joint Screws Screws and anchors KHPS Button KHPD Buttons Micro contact Micro contacts Button spring Buttons spring HPP 6 HPP 12D Plate Micro contacts with common call Lighting module Cable clamp plates Hole plug ACCESSORIES ...

Страница 6: ... at the bottom and fasten it using the screw provided fig 7 WALL MOUNTING Apply the two hole plugs at the base fig 8 Fit the embedding box HBP 3 module or round Ø 65mm version flush with the wall at an appropriate height In the case of video entry panels the height should be such as to exploit the features of the camera to the full Fasten the base onto the wall using the screws and screw anchors s...

Страница 7: ... order to fit the front plate first insert the upper part in the top moulding and then using a Allenkey s 2 5 tighten the lock screw fig 1 2 1 2 3 4 5 1 2 5 21 8 11 12 14 5 21 8 11 12 14 2 A 1 3 4 5 6 SIDE BY SIDE RECESSED INSTALLATION For horizontal fig 1 2 or vertical fig 3 4 combinations remove the hole plugs and insert the cable guide joints Fit the spacer into embedding boxes to avoid deforma...

Страница 8: ...be enabled first Activating the alarm the relay 2 is activated by pres sing key before entering your user code see fun ction 10 for disabling instructions All user codes associated with relay 1 are enabled when the alarm is activated Activating the bell the relay 2 is activated by simply pressing key once To prevent false alarms being sent the option of asso ciating usercodes with relay 2 is autom...

Страница 9: ...ult setting 5 s 1 Enter FUNCTION CODE 2 Select the RELAY you want by entering 1 or 3 Enter ACTIVATION TIME in the range 01 to 65 s 4 Repeat the procedure from point 2 to set the other relay s activation time or select another function FUNCTION 07 Setting keypad lockout time default setting 10 s 1 Enter FUNCTION CODE 2 Enter LOCKOUT TIME in the range 01 to 65 s FUNCTION 08 Setting monostable or bis...

Страница 10: ...10 ...

Страница 11: ...11 ...

Страница 12: ...nd of its life cycle take measures to ensure it is not discarded in the environment The equipment must be disposed of in compliance with the regulations in force recycling its component parts wherever possible Components that qualify as recyclable waste feature the relevant symbol and the material s abbreviation BPT S p A a Socio Unico Via Cornia 1 33079 Sesto al Reghena PN Italy www bpt it info b...

Отзывы: