General Notice
Important Safety Precautions
Note
Intended Use of the Domestic Firefighter Safety Switch

 

Location of the Domestic Firefighter Safety Switch

 

Normal Operation
Special Operation
Specification
Appearance Introduction
Wiring Diagram
Installation Introduction

BPE-FFSS-

S

3

BPE-FFSS-

S

2

 

BPE-FFSS-

S

1

 

Dimensions 

08

Содержание BPE-FFSS-S1

Страница 1: ...INSTALLATION GUIDE Firefighter PV Safety Switch BPE FFSS S1 BPE FFSS S2 BPE FFSS S3 ...

Страница 2: ...otice Important Safety Precautions Note Intended Use of the Domestic Firefighter Safety Switch Location of the Domestic Firefighter Safety Switch Normal Operation Special Operation Specification Appearance Introduction Wiring Diagram Installation Introduction BPE FFSS S3 BPE FFSS S2 BPE FFSS S1 Dimensions 08 ...

Страница 3: ...are exposed to high voltages and currents Follow these instructions carefully in order to reduce the risk of fire or electric shock The following regulations and standards are considered applicable and mandatory to read prior to the installation of electrical equipment International Standards IEC 60364 7 712 Electrical installations of buildings Requirements for special installations or locations ...

Страница 4: ...e BPE FFSS will automatically switch to OFF breaking the DC connection between the solar panels and the inverter Once the AC power to the BPE FFSS is restored the BPE FFSS will automatically switch to ON restoring the DC connection between the solar panels and the inverter Special Operation Over Temperature Shutdown If the temperature inside the BPE FFSS enclosure exceeds 85 C the BPE FFSS will au...

Страница 5: ...Strings Operating Voltage 90Vac 260Vac Nominal Voltage 220Vac Nominal Current 30mA Start Up Current Average 100mA Switch On Action Current Max 300mA Standard Compliance CE IEC EN60947 1 3 Operating Temperature Range 20 C 85 C Protection Degree IP66 Storage Temperature 40 C 85 C Max Operating Temperature Before Automatic Switch OFF 85 C Protection Level Class II Mechanical Endurance 9700 Electrical...

Страница 6: ...ncy Button Button Released and Red LED light ON 220VAC power connected Button Pressed and Red LED light OFF 220VAC power disconnected 3 Switch Indicator Indicator light RED means DC Switch ON Indicator light GREEN means DC Switch OFF 4 AC Connector Connect to AC Main Power 5 MC4 Connector PV DC Input 6 MC4 Connector PV DC Output Wiring Diagram BPE FFSS S3 ...

Страница 7: ...5 Installation Introduction Step 1 Install the switch Step 2 Press Emergency Button to keep AC circuit disconnected Step 3 Connect to AC Main Power ...

Страница 8: ...fter 60 seconds Press Emergency Button Red light OFF Switch Indicator turn RED to GREEN Step 5 Connect to PV arrays Wiring Requirement for EVO2 Note Before Connection to PV arrays Make sure the BPE FFSS is in OFF status Red Indicator OFF Switch Indicator switch to GREEN Warning All EVO2 connectors must be installed and sealed properly with isolator to maintain IP66NW rating ...

Страница 9: ...7 BPE FFSS S3 BPE FFSS S2 BPE FFSS S1 ...

Страница 10: ...8 Dimensions ...

Страница 11: ...9 ...