INSTALLATION AND OPERATOR’S MANUAL 

 
 

 

 

 
 
 
 
 
 

SL375 T

HRU

 

SL7175 

O

IL

 F

IRED

 C

AST

 I

RON

 

BOILERS

 

 

 
 

Keep these instructions with the boiler at all times for 

future reference 

 

 

B

OYERTOWN

 

F

URNACE

 

C

O

PO Box 100 

B

OYERTOWN, 

PA 19512

 

1-610-369-1450 

 

www.boyertownfurnace.com 

 

1-10-06 

Содержание Solaia SL375

Страница 1: ...MANUAL SL375 THRU SL7175 OIL FIRED CAST IRON BOILERS Keep these instructions with the boiler at all times for future reference BOYERTOWN FURNACE CO PO Box 100 BOYERTOWN PA 19512 1 610 369 1450 www bo...

Страница 2: ...n No 1 and No 2 heating oil only Never use gasoline or a mixture of gasoline and oil Do not store gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance The area...

Страница 3: ...elief Valves Expansion Tanks Venting Systems 10 Chimney Venting Direct Venting Burner Installation 14 Oil Tank and Piping 15 Wiring 15 Swing Door 18 Opening the Door Closing the Door Door Hinge Revers...

Страница 4: ...07 707 887 887 1 067 1 207 AFUE Rating 85 5 85 5 86 5 86 5 86 9 86 9 86 9 85 0 Water Capacity 3 6 3 6 4 3 4 3 5 1 5 1 5 8 6 5 Approx Shipping Weight 300 300 350 350 390 390 430 470 Cabinet Height 28 7...

Страница 5: ...ed at all times Ventilation of boiler room must be adequate enough to provide sufficient air for combustion When a boiler is located in an unconfined space in a building of conventional frame or mason...

Страница 6: ...reens used shall not be smaller than inch mesh If free area through a design of louver of grill is known it should be used in calculating the size opening required to provide the free area specified I...

Страница 7: ...anel The sensor wires should be run through the bottom knockout in the aquastat The rubber grommet provided with the sensor wires is to be securely inserted into the aquastat knockout 2 Connect the se...

Страница 8: ...upper brackets and insert into immersion well Fasten the wires into the well using the wire clamp provided Snap sensor wires into control b Honeywell L7248C1022 Run the sensor wires through the Heyco...

Страница 9: ...volume standing cast iron systems A thermostatic bypass valve will consistently ensure that return temperatures to the boiler exceed 130o F at all times See Figure 1 for Thermostatic Bypass valve pip...

Страница 10: ...t chimney shall be brought up to current requirements Chimneys which are relined shall be done so with an approved liner that will resist corrosion softening or cracking from the flue gasses All chimn...

Страница 11: ...e gasses Tees may be used in a straight section in conjunction with a barometric draft regulator however they must not be used for a 90 turn No device that will obstruct the free flow of flue gasses s...

Страница 12: ...nd sealed with high temperature sealant WARNING External vent surfaces are hot Surface discoloration of the building may occur due to improper burner or boiler adjustment We will not accept any liabil...

Страница 13: ...oles in the termination end Install the flexible vent piping with the provided connector between the boiler and the termination end The joints at the boiler vent connectors and termination end should...

Страница 14: ...installed in a level position and adjusted to lightly close while burner is operating Be sure to lock the balancing weight after adjustment ALL JOINTS IN THE AIR INTAKE ASSEMBLY MUST BE SECURELY FAST...

Страница 15: ...ll conditions Post purge is provided to ensure that the boiler fires at maximum efficiency and dependability throughout the heating season Post purge of the oil burner is controlled through the electr...

Страница 16: ...TE FUSSED DISCONNECT SWITCH ELECTRICAL SHOCK IS HAZARDOUS TURN OFF ALL POWER SUPPLIES AT SERVICE ENTRANCE BEFORE STARTING TO MAKE WIRING CONNECTIONS OR REPAIRS Refer to wiring diagrams in rear of manu...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...s must be removed from the holes in the right side and placed in the holes on the left side of the upper brackets 4 The aquastat immersion well must be moved to the upper left rear tapping and the rel...

Страница 20: ...ystem To bleed attach a clear plastic tube to the oil pump bleed port and allow oil to run until all the air is out of the oil suction line feeding the oil burner See burner and fuel pump manufacturer...

Страница 21: ...you will have a reasonable margin of built in protection before smoke generation begins Preliminary Burner Settings Boiler Burner Nozzle Air Setting Turbulator Head Pump Press CO2 Draft Overfire Smoke...

Страница 22: ...lex plug at burner 3 Remove the boiler front jacket panel by lifting vertically 4 Open the swing door following previously described procedure 5 If required remove scale and any soot deposits with a f...

Страница 23: ...Vent Inspect and clean vent and air intake piping Replace and reseal joints as required Inspect vent hood air inlet and discharge for obstruction Domestic Hot Water Storage Tank 1 Sizing of the hot wa...

Страница 24: ...Volts at Burner Refer to Oil Burner Manual Adjust Thermostat Adjust High Limit Check Fuses and Safety Switches Aquastat in Fault Condition Refer to Aquastat Manual Remove Thermostat Wires From Aquast...

Страница 25: ...Open All Supply Valves Oil Filter Clean Pump Strainer Clean Replace Oil Filter Clean or Replace Strainer Check All Fitting Connections Adjust Pressure to Burner Specs Ignition Electrode Shorted or Cr...

Страница 26: ...1 Reducing Coupling 3 4 x 1 2 328001 328001 328001 328001 328001 11 1 Drain Valve 1 2 328000 328000 328000 328000 328000 12 1 Street Elbow 3 4 328002 328002 328002 328002 328002 13 1 Relief Valve 3 4...

Страница 27: ...osits or corrosion in or on the cast iron sections 6 This warranty applies only to boilers installed in the United States 7 In order for this warranty to be effective a The boiler must have been insta...

Страница 28: ...tem inspected to NFPA 211 and in good condition Vent size checked against furnace manual and codes B r Operation urne Burner Model __________________ Nozzle _______GPH _______Deg ____Type_______ Burne...

Страница 29: ...____________________________________________________________________ Purchaser s Address ________________________________________________________________________ ______________________________________...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...32...