www.boxerpumps.com
6900.011-01
Page 1
iD Peristaltic Pump Driver
User Manual
www.boxerpumps.com
6900.011-01
Page 2
1.0 Introduction
The Boxer iD Driver is a powerful digital and programmable controller designed specifically for
use with the peristaltic pumps series 25K, 15KS/QQ and 9K/QQ with stepper motors.
Features include:
► 3 Running modes (dispense, dose and analogue)
► Calibration for volumetric dispense
► Automatic stall and open lid detection
► Push button or remote inputs
► Acceleration, deceleration, time interval, and suck-back settings
1.1
Dispense Mode
In dispense mode the pump is switched on and off by the enter key. The display will show the
dispense volume. During running or prior to starting the speed can be
changed with the up and down keys. Programmable settings are: current, cali-
bration, suck back, acceleration, deceleration, direction, stall and lid detec-
tions.
1.2
Dose Mode
In dose mode the pump will run a predefined dosing cycle with paused interval. The display
will show the dosed volume and count down during the
pause interval. Prior to starting the dose volume is set. Pro-
grammable setting are: current, calibration, dose speed,
dose interval, number of cycles, suck back, acceleration, deceleration, direction, stall and lid
detection.
1.3
Analog Mode
In analog mode the driver acts a pure analog driver. Inputs are: on/off, direction and
speed. The display will show the running speed. Programmable settings are:
current, acceleration, deceleration, speed range, stall and lid detection.
2.0 Setting-Up
With the power supply switched off, connect the iD Driver via the blue terminal block:
GND
→ GND
24V DC
→ Vin
Connect the 4 colour coded wires from the stepper motor also to the blue terminal
block:
Green
→ A2
Black
→ A1
Red
→ B1
Blue
→ B2
For stall / lid detection and remote inputs, refer to section 5.2.
Switch the power supply on.
www.clarksol.com
www.clarksol.com
Содержание iD Driver
Страница 7: ...D i me ms i o n s mm...