NOTICE:

 

 

Check and inspect all components thor-

oughly for damage/wear and replace as 

necessary.

 

 

STORAGE

 

 

Short Term Storage (6 months or less)

 

 

For storage less than 6 months the following steps are strongly advised:

 

 

1.

 

Store pumps indoors.  If this is not possible, then provide adequate protective covering.  

DO NOT 

allow moisture to collect around the pump.

 

2.

 

Remove the drain plugs, if fitted.  Remove any fitted inspection plates to ensure that the pump 
housing is dry.

 

3.

 

See Manufacturer

s Instructions for motor/gearbox/drive instructions for storage procedures.

 

 

Long Term Storage (6 months or more)

 

 

For storage longer than 6 months in addition to following the short term storage steps, the following pro-
cedures should be carried out every 2

-

3 weeks.

 

 

1.

 

Rotate the pump several full revolutions to avoid the gears setting in the housing.

 

2.

 

If corrosion is present, apply light oil to all rotating parts and repeat step 1.

 

PREVENTATIVE MAINTENANCE

 

Failure to set vehicle emergency 

brake and chock wheels before 

performing service can cause 

severe personal injury or prop-

erty damage.

 

Failure to disconnect and lock-

out electrical power or engine 

drive prior to performing ser-

vice can cause personal injury 

or property damage. 

 

Failure to relieve system pres-

sure prior to performing ser-

vice can cause personal injury 

and property damage

 

If pumping hazardous or toxic 

fluids, pump must be flushed 

before service.

 

Содержание Eco-Seal Series

Страница 1: ...e system MUST conform to all applicable local and national regulations and safety standards This manual is intended to assist in the in stallation and operation of the Bowie Eco Seal Series pumps and when possible kept with the pump Pump service shall be performed by quali fied technicians ONLY Service shall con form to all applicable local and national reg ulations and safety standards Thoroughly...

Страница 2: ...ringent environmental and safety standards There are three lines of Eco Seal Series pumps 300 Eco Seal the standard pump 300 Eco Seal S short drive neck for ac cess in tight spaces 300 Eco Seal ED extended duty PUMP DIMENSIONS EXPLODED VIEWS AND OTHER TECHNICAL INFORMATION All technical information including pump dimensional diagrams exploded views with part listings and other technical informatio...

Страница 3: ... lines and piping MUST be free of all leaks NOTICE Bowie pumps must be installed only in systems design by qualified engineering personnel Bowie pumps should only be installed in duties for which Bowie Pumps of Canada Ltd have specified the attributes of the pump System design must conform to all applicable regulations and codes and provide warning of all system hazards NOTICE PTO and hydraulicall...

Страница 4: ...ng a surging vibration to the fluid system POWER TAKE OFF PTO DRIVE Bowie pumps may be driven by a PTO drive A direct drive shaft with a universal joint on each end of the shaft is used to connect the pump to the drive A sleeve joint can be used to compensate for any play caused by road conditions General guidelines for proper pump drive 1 The angle of drive shaft between pump and PTO must be NO L...

Страница 5: ...ge line and reading the pressure gauge This pressure must be a minimum of 20 30 psi 1 4 2 1 Bar higher than the maximum system operating pressure or pressure relief plate setting and must not exceed 150 psi DO NOT operate the pump against a closed discharge valve for more than 15 seconds If adjustments need to be made refer to the Relief Valve Setting and Adjustment sec tion of this manual NOTICE ...

Страница 6: ...ons with sticky fluids that solidify within the pump i e waxes adhesives etc use a fluid that prevents solidification of the fluid to facilitate flushing NOTICE Properly dispose of all waste fluids in ac cordance with appropriate codes and regu lations PUMP OPERATION Disconnecting fluid or pressure containment components dur ing pump operation can cause serious personal injury death or major prope...

Страница 7: ...ngs Tighten the locking nut and replace the locking cap Selecting the CORRECT LOCKING CAP viewing the front plate of the pump To adjust flow pressure for CLOCKWISE shaft rotation a The drive shaft below the idler shaft Adjustments must be made to the RIGHT side spring b The drive shaft above the idler shaft Adjustments must be made to the LEFT side spring To adjust flow pressure for COUNTERCLOCKWI...

Страница 8: ...s of grease applied approximately every four 4 operating hours in the front drive neck of the pump For all other grease fitting locations we recommend 1 2 ounces of grease applied every four 4 operating hours The actual amount of grease to be applied can be identified as the point when high re sistance to further greasing has been achieved For operating conditions above those specified refer to th...

Страница 9: ...ore For storage longer than 6 months in addition to following the short term storage steps the following pro cedures should be carried out every 2 3 weeks 1 Rotate the pump several full revolutions to avoid the gears setting in the housing 2 If corrosion is present apply light oil to all rotating parts and repeat step 1 PREVENTATIVE MAINTENANCE Failure to set vehicle emergency brake and chock whee...

Страница 10: ... or toxic fluids pump must be flushed before service PUMP DISASSEMBLY 1 Remove the two drain plugs 3318 from back plate 2 Remove the three end plugs 4308BF from the front and back plates 3 Remove secure wire from packing nut and packing nut itself 4301 4 Remove the quick change sleeve ECOEDSL and quick change containment seal 3325V from the Drive shaft 5 Remove all bolts on the back plate and remo...

Страница 11: ...additional housing gasket on to hardened wear plate 10 Apply light oil on two seals and around the seal pockets in the back plate Insert one lip seal 3325 on to each of the two shafts ends Keep lips orientation toward the casing 11 Mount back plate with four bolts tightening in a cross pattern 12 Turn drive shaft to ensure proper meshing of gears and acceptable clearances between the gears and pla...

Страница 12: ...ne Damaged or worn parts Pressure Relief Plate is set too low or attached incorrectly if installed Pump speed is too fast for viscosity or volatility of the liquid Pump not securely mounted Loose undersized piping and fittings Pump is too far from fluid source Improper drive or hydraulic connection Dry running the pump Excessive heat in the pump Excessive discharge pressure Cavitation Normal end o...

Страница 13: ...ES IOM Rev 1 5 13 2021 13 CONTACT INFORMATION Bowie Pumps of Canada Ltd 9333 41 Ave T6E 6R5 Edmonton AB Tel 1 877 862 6943 Email info bowiepumps com ...

Отзывы: