Protection, Errors and Firmware Updates
Overheat Prevention
To prevent the unit from overheating, the XMT includes internal temperature sensors
that will automatically enable the overheat function after excessive use. To prevent the
overheat function fom enabling, do not fire the unit at full power more than 100 times in
quick succession.
If the temperature sensors enable the overheat function the XMT will automatically
reduce flash recycle to over 10 seconds. If this occurs allow the unit rest and cool for at
least 10 minutes before commencing use.
Error Codes
In case of failure the following is a list of unit error codes:
ERROR CODE
E1
Recycling error.
DESCRIPTION
E2
Excessive heat.
E3
Flashtube error.
E4
Software error.
Restart the unit. If problem persists send to Bowens for servicing.
SOLUTION
Allow the unit to rest for at least 10 minutes.
Restart the unit. If problem persists send to Bowens for servicing.
Update to latest firmware.
Firmware Updates
The XMT firmware may be updated via the micro USB connector.