Bowens ESPRIT digital DX 250 Скачать руководство пользователя страница 2

Esprit Digital Operating Instructions 

 

15 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2 

SPECIFICATION 

Esprit Digital: 

250DX 

500DX 

Stored Energy (Max) 

250Ws 

500Ws 

Typical Recycle Time 
(Full Power 117V 60Hz) 

1.2 seconds 

1.5 seconds 

Supply Voltage AC 

95-130V 50 or 60Hz 

95-130V 50 or 60Hz 

Stabilisation 

+/- 0.05 f-stop 

+/- 0.05 f-stop 

Modelling Lamp 

Max 275W 

Max 275W 

Ready Indication 

Green ‘READY’ 

LED 

at 100%

Audible and Modelling light  
indication as selected. 

Green ‘READY’ 

LED 

at 100% 

Audible and Modelling light  
indication as selected. 

Fuse 

10A (T) 20mm 

10A (T) 20mm 

Nominal Sync. Voltage 

14V 

14V 

Photocell On/Off 

On/Off 

Sounder On/Off 

On/Off 

Modelling Power Control 

Off / Proportional / 
Independent / 100% 

Off / Proportional / 
Independent / 100% 

IR Remote Control 

Full control, 12 channels 
No. depends on transmitter 

Full control, 12 channels 
No. depends on transmitter 

Guide Number:  
Full power, 50

°

 Keylite, ISO 100 

60m   

82m   

Flash Duration (Full Power) t=0.5 1/1100s 

1/700s 

Flash Colour Temperature 

Approx. 5900K (Clear tube) 
Approx. 5300K (UV coated) 

Approx. 5900K (Clear tube) 
Approx. 5300K (UV coated) 

Flash Power Control 

Full to 1/32   
5 f-stop in 1/10 increments 

Full to 1/32   
5 f-stop in 1/10 increments 

Recommended Modelling Lamp 

250W 120V Halostar 
275W 120V Photoflood 

BW-1024/B 
 

Flash Tube Assembly 

Clear 
UV-Coated 

BW-2030 
BW-2032 

Dimensions L 

=390mm 

W=170mm 
H =125mm 

Weight 3.0Kg 

3.2kg 

 

Due to our policy of constant product improvement Bowens International Limited reserve the right 
to change equipment specifications without notice. 

ACCESSORIES 

For details of all related products please contact your local distributor. 

Lamp Function Control

Test / Open Flash

Ready LED 

Function Display Controls 

Function Display

IR Remote 

Receiver 

AC Connection

Fuse (+ Spare Fuse)

Sync 
Socket 

Power  
On/Off Switch

Содержание ESPRIT digital DX 250

Страница 1: ...R THE 250DX 500DX 117V ESPRIT DIGITAL INSTRUCTIONS BWL 0322 1 10 1 02 BOWENS INTERNATIONAL LIMITED 355 OLD ROAD CLACTON ON SEA ESSEX CO15 3RH UNITED KINGDOM Tel 44 0 1255 422807 Fax 44 0 1255 436342 www bowensinternational com ...

Страница 2: ...ll control 12 channels No depends on transmitter Guide Number Full power 50 Keylite ISO 100 60m 82m Flash Duration Full Power t 0 5 1 1100s 1 700s Flash Colour Temperature Approx 5900K Clear tube Approx 5300K UV coated Approx 5900K Clear tube Approx 5300K UV coated Flash Power Control Full to 1 32 5 f stop in 1 10 increments Full to 1 32 5 f stop in 1 10 increments Recommended Modelling Lamp 250W ...

Страница 3: ... Confirm that the fuse is intact and if in doubt replace A spare fuse is fitted in the fuse holder always replace with a fuse of the correct type and rating If the fuse blows immediately the unit is switched on remove the modelling lamp replace the fuse and try again If the fuse blows again there is an internal fault The Control Panel Lights but Does Not come To READY If this happens then first co...

Страница 4: ...he latch knob is in the closed position To remove reflector push the Latch Knob towards the rear of the unit turn the reflector fully counter clockwise and withdraw Note A Photoflood or Halostar bulb with a maximum wattage of 275W is recommended for use in Esprit Digital units The manufacturer will not accept liability for the use of any lamp with a rating exceeding 275W The unit has a built in so...

Страница 5: ...ot to damage the flash tube assembly The flash tube is very delicate avoid unnecessary handling of the glass tube Always switch off and disconnect from the supply before changing the flash tube assembly AC Supply The unit operates from an AC Line voltage within the range 95V to 130V with a nominal frequency of either 50Hz or 60Hz Ensure that the Power ON OFF switch on the unit is set to OFF Use a ...

Страница 6: ...l the display changes to show one of the values below Release the button If the SOUNDER is on it will sound continuously while the FUNCTION button is held down Now momentarily press the FUNCTION button to scroll through the options until the desired one is reached as follows Display Range X X Description X X X 0 0 0 to 9 9 9 Firmware version di X 1 to 9 Display brightness value Use UP or DOWN to a...

Страница 7: ...e 1 is minimum and 9 is the maximum Use UP or DOWN to adjust Default factory setting is di 7 UP DOWN Buttons Select the required FUNCTION as detailed above Single presses of the UP or DOWN buttons will increment or decrement the value by one Hold the appropriate button down to automatically increment or decrement the value Release the button when the required value is reached and then use momentar...

Страница 8: ...tomatically discharges the capacitors when the power is reduced The READY indicator flashes while the unit is dumping The user may select one of two DUMP methods by means of the OPTIONS sub menu See OPTIONS for a description of how to access this mode The default factory setting is Fd 0 In this mode the unit resistively dumps excess energy whenever the flash setting is reduced This is a relatively...

Отзывы: