background image

Esprit Digital 750 Operating Instructions 

Esprit Digital 750 Operating Instructions 

 

14 

 

 

WARNINGS & FAULT FINDING 

If the unit appears to have developed a fault, first establish that it is a genuine internal fault 
and not a case of normal operation such as overheat.  Carry out the following checks to 
eliminate any external causes.  If no obvious problem can be found and replacement of the 
modelling lamp, flash tube or fuses do not effect a cure then it is likely that an internal fault 
has developed.  Always return the unit to an authorised service centre if a fault is suspected 
after these checks.  UNDER NO CIRCUMSTANCES SHOULD YOU ATTEMPT ANY 
REPAIR yourself. 

MIS-FIRE Warning 

If the unit receives a trigger signal from any of the valid sources (TEST, IR REMOTE, IR 
TRIGGER, SYNC) but fails to flash for any reason then the display will flash continuously 
and the sounder will beep (if on).  Press any button, apart from TEST, to stop this alarm.  
Increase the power setting to maximum and use the TEST button to try and flash again.  If 
the problem continues to happen on more than the odd occasion, particularly at lower power 
settings, then it is likely that the tube is wearing out.  Before replacing the tube, check that 
the trigger wire is correctly connected and is not shorted to or in close proximity to the metal 
reflector.  If the unit fails to flash at all then check the flash tube for signs of damage or 
overheating. 

If the unit fails to flash and the display warning is not given then the Sync. lead and/or 
camera should be suspected.  If possible check these with another flash system.  Check the 
polarity of the Sync. from the camera and use an adapter to reverse it if necessary.  The 
DIGITAL 750 supplies a positive SYNC. voltage of 14V with respect to the chassis Ground. 

OVERHEAT Warning 

The unit is fitted with overheat detectors that turn the modelling lamp off and inhibit charging 
until the unit has cooled sufficiently.  The display flashes ‘OH’ and the fan continues to cool 
the unit while the overheat condition exists.  An audible warning is not given since this may 
last for some time.  Overheat will normally only occur if the unit is flashed repeatedly at a fast 
repetition rate or if the cooling fan has failed.  Listen for the fan running.  Slowing down the 
repetition rate will normally help keep the unit out of overheat.  Dimming the modelling lamp 
or turning it off may also help. 

NOTE:  The controls are inhibited during overheat to prevent inadvertent changes being 
made.  If the lamp was on before the OH condition existed then the lamp display will show it 
as being temporarily switched off. 

The Unit Display Panel Does Not Light 

If the display panel does not light when the unit is switched on then first check that the AC 
power supply to the unit is OK.  Under exceptional conditions of use the main fuse may blow.  
This is normal and is designed to protect the unit.  Confirm that the main fuse is intact and if 
in doubt try a spare.  Spare fuses can be found under the rubber covers in the handle.  If the 
unit immediately blows the main fuse then there is an internal fault. 

The Unit Display Panel Lights But Does Not Come To ‘READY’ 

If this happens then first confirm that the AC power supply is adequate and within the 
prescribed limits.  Try switching the unit off, wait a minute, then switch on again. 

The Modelling Lamp Does Not Light. 

Check the modelling fuse and the modelling lamp itself.  Replace as required. 

 

GENERAL 

Welcome to the world-wide family of Bowens flash equipment users, and congratulations on 
selecting the Esprit Digital 750.  This has been designed using the latest technology to 
produce a unit that is simple to operate, yet has a powerful, highly controllable and accurate 
output.  Please familiarise yourself with these instructions before operating the unit. 

SAFETY NOTES 

  The Esprit Digital 750 must not be used in an environment where moisture or flammable 

vapour is likely to come in contact with the unit. 

  When moving the unit from extremes of temperature and humidity, allow at least one 

hour for the unit to stabilise at room temperature before connecting it to the supply. 

  A fire hazard exists if flammable materials are placed in close proximity to either the 

flashtube or modelling bulb when the unit is in use. 

  Do not restrict the slots in the case when in use. 

  Care must be exercised when handling equipment that has been in use.  The reflector 

and front end of the unit can become Very Hot. 

  Switch off and disconnect supply before changing fuse(s), modelling bulb or flashtube. 

  Only fit a modelling lamp of the correct wattage & rated for the local AC Line voltage. 

  The Esprit Digital 750 is protected by a 10A (T) 20mm fuse and a separate 4A (F) 20mm 

fuse for the modelling.  These are mounted underneath the unit adjacent to the mains 
inlet.  Never replace either fuse with one of a different rating or type. 

  Only connect the unit to a 3-wire, earthed (grounded), supply with an AC Line voltage 

within the ranges 90V to 130V or 190V to 253V with a nominal frequency of either 50Hz 
or 60Hz.  Unregulated or poorly regulated generators should not be used. 

  Avoid trailing supply cords and sync leads where they can be tripped over. 

  Never use a unit with damaged covers, mouldings, glass dome, flash tube or modelling 

bulb.  If the unit is dropped or damaged in any way always have it checked out before 
using. 

  Due to the high voltage / high energy used in the Esprit Digital 750, all servicing should 

only be carried out by an authorised Service Centre. 

CONTENTS OF CARTON 

  Esprit Digital 750 with flashtube 

  Sync. cord 

  Instructions 

  Safety Leaflet 

 

Additional items may be supplied for use in specific countries. 

 

Содержание ESPRIT DIGITAL 750

Страница 1: ...5 Instructions BWL 0309 1 BOWENS INTERNATIONAL LIMITED 355 Old Road Clacton on Sea Essex CO15 3RH Tel 44 0 1255 422807 Fax 44 0 1255 43634 Esprit DIGITAL 750 100V 117V 230V 50 60Hz OPERATING INSTRUCTI...

Страница 2: ...smitter Guide Number Full Power 50 Keylite 100 ISO 102m 335ft Flash Duration t 0 5 250W s Variator set to F10 500W s 750W s 1 3250 1 2240 1 1700 Flash Colour Temperature Approx 5300K UV coated cover g...

Страница 3: ...n first check that the AC power supply to the unit is OK Under exceptional conditions of use the main fuse may blow This is normal and is designed to protect the unit Confirm that the main fuse is int...

Страница 4: ...the power be increased to maximum and the unit left switched on occasionally for at least 30 minutes to help preserve the life of the capacitors You are now ready to use the system MODELLING LAMP REPL...

Страница 5: ...ds 300 30 minutes F10 FULL Less than 1 5 seconds 50 2 minutes F8 0 1 4 5 seconds or more Unlimited Continuous F8 0 1 4 2 5 seconds 900 50 minutes F8 0 1 4 Less than 1 5 seconds 150 6 minutes F5 0 1 32...

Страница 6: ...DOWN button changes the value by 0 1 f stop 1 10 to give a total of 51 values E g If the current value shown is 9 4 then to reduce the power by 1 f stop just reduce it to 8 4 The following table shows...

Страница 7: ...bracket exposures without having to adjust either the camera or the flash power settings Once set the DIGITAL 750 will automatically increase or decrease the FLASH setting by an identical fraction of...

Страница 8: ...that it has recharged to READY and is in addition to the normal indication Press the INT button to switch this function on or off The associated LED is lit when INT is on Depending on the OPTION sett...

Отзывы: