14. Operation 

  Switch the unit ON, plug in the sync cord and connect to camera shutter at ‘x’ 

synchronisation. Alternatively, plug in Infra Red Receiver or Omnicell. Switch ON and 
select modelling lamp ON or OFF and flash power required. When the unit is ready to 
fire the green LED (Fig.2. 3) will light. Press Open Flash Pushbutton (Fig.2. 5) and 
check that the unit operates correctly. The open flash button should also be pressed 
after the flash power setting has been reduced, to ensure that the next flash is of the 
required power. 

 

15. Mounting 

  Mount the Esprit 2 125 unit on selected support system. The mounting bush on the ‘L’ 

bracket allows for two possible ways of mounting to the stand / support (Fig.4). Method 
B may be found useful if the light is required to point down. 

 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 
 
 
 

1. General 

Welcome to the world-wide family of Bowens flash equipment users, and 
congratulations on selecting the Esprit 2 125. The Esprit 2 125 has been designed 
using the latest technology, to produce a unit that is very simple to operate, small in 
size and weight, yet has a powerful output. 

 

2. Safety Notes 

  The Esprit 2 125 must not be used in an environment where moisture or flammable 

vapour is likely to come in contact with the unit. 

 

  A fire hazard exists if flammable materials are placed in close proximity to either the 

flashtube or modelling bulb when the unit is in use. 

 

  The charging and modelling circuitry of the Esprit 2 125 is protected by a 5A 20mm fuse 

mounted on the rear panel (Fig.1. 1). Disconnect the supply before changing the fuse. 

Never

 replace with a fuse of a different rating. A spare 5A fuse is fitted in the fuse 

holder. 

 

  Switch off and disconnect supply before changing fuse, modelling bulb or flashtube. 

 

  Do not restrict slots in case when in use. 

 

  Care must be exercised when handling equipment that has been in use. The reflector 

and front end of the unit can become 

Very Hot

 

  Due to the high voltage / high energy used in Esprit 2 125, all servicing must be carried 

out by an authorised Service Centre. 

 

3. Contents Of Carton 

  Esprit 2 125 230V with flashtube 

 Sync. 

cord 

 Instructions 

 

4.  Fitting the Modelling Lamp

 

  Switch off and disconnect from supply. Screw modelling lamp into ES lampholder in 

the centre of the reflector. 

 

 

Note

: It is recommended that a Photoflood or Halostar bulb with a maximum wattage 

of 275W is not exceeded for the Esprit 2 125 unit.  The manufacturer will not accept 
liability on the use of any lamp with a greater wattage than 275W. 

 

5.  Power Supply Connections 

  230V AC 50Hz 

Use the mains lead supplied to connect to the mains supply. 

 

6.  Mains On/Off Switch 

  The green illuminated On/Off switch (Fig.1. 5) on the rear panel controls the power to 

both the flash and the modelling lamp. Setting the switch to 1 turns the unit ON and 0 
turns the unit OFF. 

 

 

Fig.4 

Содержание ESPRIT 2 125

Страница 1: ...t 2 125 230V Instructions BW 2055 BWL 0299 1 BOWENS INTERNATIONAL LIMITED 355 Old Road Clacton on Sea Essex CO15 3RH Tel 44 0 1255 422807 Fax 44 0 1255 436342 ESPRIT 2 125 230V BW 2055 OPERATING INSTRUCTIONS ...

Страница 2: ......

Страница 3: ...erature Apx 5300K UV coated as std Flash Power Control Full to 1 4 2 F stops fully variable Recommended Modelling Lamp 250W 240V Halostar 250W 220V Halostar 275W 220 240V Photoflood BW 1024 BW 1024 A BW 1824 Flash Tube Assembly Clear UV Coated BW 1075 BW 1074 Dimensions L 318mm W 145mm H 145mm Weight 2 2Kg Due to our policy of constant product improvement Bowens International reserve the right to ...

Страница 4: ......

Страница 5: ...ble materials are placed in close proximity to either the flashtube or modelling bulb when the unit is in use The charging and modelling circuitry of the Esprit 2 125 is protected by a 5A 20mm fuse mounted on the rear panel Fig 1 1 Disconnect the supply before changing the fuse Never replace with a fuse of a different rating A spare 5A fuse is fitted in the fuse holder Switch off and disconnect su...

Страница 6: ......

Страница 7: ...is protected by a single 5 amp F 20mm fuse mounted on the rear panel Never replace the fuse with one of a different rating As the fuse may blow when the modelling lamp fails always check the fuse when replacing the bulb A spare fuse is supplied in the fuse holder Always switch OFF the Esprit 2 unit before changing the bulb or fuse 12 Fitting Removing A Reflector A range of reflectors is available ...