Bowens CREO 1200 Скачать руководство пользователя страница 11

technical specifications

11 

- Cr

eo | 

technical specifications

CREO 1200

Rated Energy (F10)

1200Ws

Input Power Supply

100-127V / 200-240V 50/60Hz

Automatic Multi-Voltage

Yes (use appropriately rated modelling lamp)

Fuse

Slow Blow Fuse 16A @ 230V / 20A @ 117V

Auto Fuse / Breaker Per Generator

Type C,D,E 16A / 230V, 20A / 117V

Digital Energy Display

Yes (in digital F-Stops)

Max Number of Heads

2

Total Energy Control Range

F2.0 - F10.0

Energy Control Increments

1-Stop and 1/10-Stop Adjustments

Energy Distribution

Channel A=F2.0-F10.0 / Channel B=F2.0-F9.0

Auto Power Dumping

Yes

Manual Power Dumping

Yes

Speed Control

100%, 75%, 50% and 25%

Ready Indications

Beep, Lamp Dimming and Beep+Lamp Dimming

Max Rated Modelling Lamp

300W @ 120V / 650W @ 230V

Sync Sockets

2 x 1/4” phono jack sockets

Photocell Sync

Yes - Flash/IR Slave with noise filter

Radio Sync

Yes - compatible with Pulsar Radio Module

Cooling

Managed Multiple Fans

Size

36 x 29.7 x 20.5cm / 14.2 x 11.7 x 8.1”

Weight

12Kg / 26.5lbs

CREO 1200 PERFORMANCE

Guide Number (@3m / 100ISO )

128.7 (with Keylite Reflector)

Recycle Time (to full power / 100%)

0.56 seconds

Repetition Rate at 100% Speed & Power Level

2.0 - 8 Flashes / 4.0 - 6 Flashes / 6.0 - 4 Flashes

Repetition Rate at 100% Speed & Power Level

8.0 - 3 Flashes / 10.0 - 1.7 Flashes

Flash Duration @ t=0.5

1/5000 sec (min power) - 1/2400 sec (max power)

Energy Stability Flash to Flash

± 1/50 F-Stop

Colour Stability Flash to Flash

± 40K

Colour Stability Energy Range

10.0 - 7.0 = ±65K

Colour Stability Energy Range

10.0 - 4.0 = ±80K

Colour Stability Energy Range

10.0 - 2.0 = ±175K

CREO 2400

Rated Energy (F10)

2400Ws

Input Power Supply

100-127V / 200-240V 50/60Hz

Automatic Multi-Voltage

Yes (use appropriately rated modelling lamp)

Fuse

Slow Blow Fuse 16A @ 230V / 20A @ 117V

Auto Fuse / Breaker Per Generator

Type C,D,E 16A / 230V, 20A / 117V

Digital Energy Display

Yes (in digital F-Stops)

Max Number of Heads

2

Total Energy Control Range

F1.0 - F10.0

Energy Control Increments

1-Stop and 1/10-Stop Adjustments

Energy Distribution

Channel A=F1.0-F10.0 / Channel B=F1.0-F9.0

Auto Power Dumping

Yes

Manual Power Dumping

Yes

Speed Control

100%, 75%, 50% and 25%

Ready Indications

Beep, Lamp Dimming and Beep+Lamp Dimming

Max Rated Modelling Lamp

300W @ 120V / 650W @ 230V

Sync Sockets

2 x 1/4” phono jack sockets

Photocell Sync

Yes - Flash/IR Slave with noise filter

Radio Sync

Yes - compatible with Pulsar Radio Module

Cooling

Managed Multiple Fans

Size

44.2 x 29.7 x 20.5cm / 17.4 x 11.7 x 8.1”

Weight

15.35Kg / 33.85lbs

CREO 2400 PERFORMANCE

Guide Number (@3m / 100ISO )

186.5 (with Keylite Reflector)

Recycle Time (to full power / 100%)

0.9 seconds

Repetition Rate at 100% Speed & Power Level

1.0 - 8 Flashes / 3.0 - 6 Flashes / 5.0 - 4 Flashes

Repetition Rate at 100% Speed & Power Level

7.0 - 3 Flashes / 10.0 - 1 Flash

Flash Duration @ t=0.5

1/5000 sec (min power) - 1/1500 sec (max power)

Energy Stability Flash to Flash

± 1/50 F-Stop

Colour Stability Flash to Flash

± 40K

Colour Stability Energy Range

10.0 - 7.0 = ±50K

Colour Stability Energy Range

10.0 - 3.0 = ±80K

Colour Stability Energy Range

10.0 - 1.0 = ±180K

Fastest Camera Shutter Speed

1200Ws 1/500 with cable, IR. 1/250 with Pulsar

Fastest Camera Shutter Speed

2400Ws 1/500 with cable, IR. 1/250 with Pulsar

Содержание CREO 1200

Страница 1: ...Owner s Handbook...

Страница 2: ...judged to have experienced any of the following points failure to follow working instructions correctly accidental or willful damage misuse alteration or repair by a non authorised Bowens service repa...

Страница 3: ...ch turn power OFF before before fitting or removing any flash heads Avoid placing cables where they can be tripped over Protect from heavy sharp or hot objects which may cause damage and replace damag...

Страница 4: ...ling Mode Button PG 7 I Flash Open Test Button PG 9 J Mains AC Power Connection K Radio Trigger Card Slot PG 7 L Channel B Socket M Channel B LED Display N Power On Off Button O Channel B 1 Stop Power...

Страница 5: ...ators 2 Channel A Power Adjust 3 Modelling On Off 4 Ready Indications 5 Channel Select 6 Channel B Power Adjust 7 Modelling Mode 8 Sync Options 9 Flash Open Test A Accessory Release Latch B Flash Tube...

Страница 6: ...us beep until the flash power adjust button is released The generator will not alter the actual power level setting until a short period after the user has stopped changing the setting this is to avoi...

Страница 7: ...ach channel will be displayed on the appropriate channel LED displays The modelling output setting for each channel can then be adjusted independently by using the STOPS and TENTHS buttons regardless...

Страница 8: ...dicate a button press Because of the fast recharging capabilities of the Creo the lamps may appear to not dim with low flash power settings NB The dim ready indication will only be enabled if the mode...

Страница 9: ...ycling speed 25 is approximately four times as long as the fastest 100 recycling speed This option should be selected when the Creo is connected to a mains power supply with weak fuses or inadequate s...

Страница 10: ...und and removed OVERHEAT if the charge limiter fails to prevent the temperature rising then the recharging will stop completely This will be indicated by OH on both channel LED displays The generator...

Страница 11: ...0 4 0 80K Colour Stability Energy Range 10 0 2 0 175K Creo 2400 Rated Energy F10 2400Ws Input Power Supply 100 127V 200 240V 50 60Hz Automatic Multi Voltage Yes use appropriately rated modelling lamp...

Страница 12: ...O 2400 BW 9000 CREO FLASH HEAD BW 7760 FLASH TUBE CLEAR BW 3019 MODELLING LAMP 230V 650W BW2503 300W BW2504 MODELLING LAMP 117V 300W BW7515 GLASS DOME UV COATED BW 2981 GLASS DOME CLEAR BW 2982 GLASS...

Отзывы: