Introduction 

Safety Notes

3

18

DO NOT

:

• Use in an environment where moisture or flammable vapour might come in contact with the unit.

• Insert or remove flash heads without first switching of

f.

• Restrict air vents while in use.

• Use a unit with damaged housing, moldings, flash tube or modelling lamp.

If the unit is dropped or damaged in any way

, always have it checked out before using.

• Operate the unit without a safe grounded (earthed) 

AC supply

.

DO:

• Switch power of

f and disconnect from the supply before changing modelling bulb or flash tube.

• Exercise care when handling equipment that has been in use. 

The reflector and front end of 

the flash head can become V

ery Hot.

• Observe the mains supply requirements.

• 

A

void placing cables where they can be tripped over

. Protect from heavy

, sharp or hot objects, 

which may cause damage and replace damaged cables immediately

.

• Due to the high voltage / high energy used in QUADX Units, all servicing must be carried out 

by an authorised Service Centre.

• Remove the power cord by gripping the plug. NEVER pull the cord.

• Ensure that any extension cord used has a suitable current rating to prevent overheating and 

never use coiled extension cords.

• 

AL
W

A

YS remove the flash head covers before using.

Dear Customer

,

Thank you for choosing the Bowens QUADX 3000 Generator

Accurate, powerful and simple to use, the QUADX has been designed by working closely with

photographers to develop a system that meets the standards demanded in professional

photographic studios.  

All ‘S-T

ype’

accessories from the Bowens range can be used with the QUADX head. For

details of all related products, please contact your local distributor

, a list of which can be found

at www

.bowens.co.uk.

In order to obtain the full benefit from your purchase, please take a few moments to familiarise

yourself with this user manual.

Thank you.

Bowens International Ltd.

W

ARNINGS & F

AUL

T FINDING

If the unit appears to have developed a fault, first establish that it is a genuine internal fault and not a

case of normal operation such as overheat.  Carry out the following checks to eliminate any external

causes.  If no obvious problem can be found and replacement of the modelling lamp, flash tube or fuse

does not ef

fect a cure then it is likely that an internal fault has developed.  

Always return the unit to an

authorised service centre if a fault is suspected after these checks.  UNDER NO CIRCUMST

ANCES

SHOULD YOU 

A

T

TEMPT

ANY

REP

AIR 

yourself.

Flash/Misfire W

arning

Following a flash, the unit will temporarily display READY

on the red numeric displays for 5 seconds.

This serves as a convenient method of showing correct pack operation when two or more packs are

running flashing together

.  If the unit receives a trigger signal from any of the valid sources (TEST

, IR

REMOTE, IR 

TRIGGER, SYNC) but fails to flash for any reason then the red numeric will display

“headfail”.   Press – to clear the message.  Increase the power setting to maximum and use the 

TEST

button to try and flash again.  If the problem continues to happen on more than the odd occasion,

particularly at lower power settings, then it is likely that the flash head tube is wearing out.  Before

replacing the tube, check that the trigger wire is correctly connected and is not shorted to or in close

proximity to the metal reflector

.  If the unit fails to flash at all then check the flash tube for signs of

damage or overheating.

If the unit fails to flash and the display warning is not given then the Sync. lead and/or camera should

be suspected.  If possible check these with another flash system.  Check the polarity of the Sync. from

the camera and use an adaptor to reverse it if necessary

.  

The QuadX 3000 supplies a SYNC. voltage

of +5V with respect to the chassis Ground.

OVERHEA

T W

arning

The unit is fitted with overheat protection that inhibits charging until the unit has cooled suf

ficiently

.  

The

display flashes the READY

LED and displays a warning message on the LCD while the overheat

condition exists. Overheat will normally only occur if the unit is flashed repeatedly at a fast repetition

rate. Slowing down the repetition rate will normally help keep the unit out of overheat.  Dimming the

modelling lamp or turning it of

f may also help.

NOTE:  

The controls are inhibited during overheat to prevent inadvertent changes being made.  

The

overheat condition remains until the pack reaches a target lower temperature or is turned of

f and then

on after the pack has cooled by a few degrees.

The Control Panel Does Not Light

If the control panel does not light when the unit is switched on then first check that the 

AC power supply

to the unit is OK and that the thermal resets buttons on the rear are set.  Under exceptional conditions

of use the internal fuse may blow

.  
This is normal and is designed to protect the unit.  Report the

problem to your local service agent.  Do not attempt to locate and replace the internal fuse.

The Control Panel Lights but Does Not come T

o

 'READY'

If this happens then first confirm that the 

AC power supply is adequate and within the prescribed limits.

T

ry switching the unit of

f, wait a minute, and then switch on again.

W

arnings

QU
A

DX

Содержание BW-7600

Страница 1: ...UADX GENERATOR INSTRUCTIONS BWL 0335 2 08 05 BOWENS INTERNATIONAL LIMITED 355 Old Road Clacton on Sea Essex CO15 3RH UK Tel 44 0 1255 422807 Fax 44 0 1255 436342 www bowens co uk OPERATING INSTRUCTION...

Страница 2: ...4 x Max 650W On Off On Off 6 6 f stop in 1 10 increments scaled 10 3000Ws 175 UV Coated Tube 1 1430s Full Power t 0 5 Approximate value indicated Approx 6500K UV Coated QUADX Head BW 7660 360mm 14 1 2...

Страница 3: ...ire Warning Following a flash the unit will temporarily display READY on the red numeric displays for 5 seconds This serves as a convenient method of showing correct pack operation when two or more pa...

Страница 4: ...reen there are three toggle controls to switch the photocell I R remote and modelling on or off To the right of the screen there is a pair of adjustment buttons to raise or lower the power from channe...

Страница 5: ...n the unit is not ready There are three modelling modes Full Proportional and automatic 100 The Full and Automatic 100 modes also provide a bias control allowing all lamps to be controlled in ratio Ma...

Страница 6: ...rols to provide the desired settings and select any options required Refer to the section on operation of the controls if required Test flash the unit by pressing the TEST button Excess energy is auto...

Страница 7: ...t HINT Whenever a flash mode is enabled the default menu will show Progmd on the default menu in order to show a mode is in place All modes are switched OFF after powering off the unit Advanced Option...

Страница 8: ...ing the pack the user must consider the electrical load placed upon the mains supply As a worst case with four heads plugged in using 650W of modelling each the mains supply could be overloaded with c...

Страница 9: ...power Advanced Options Alternate Units to toggle between Joules and Percentage ADVANCED OPTIONS RESET JOB COUNT SPEAKER SETUP ALTERNATE UNITS The Information Menus The DEFAULT MENU shown here display...

Страница 10: ...nged to start at a low power working upwards or alternatively may begin at a high power and work downwards The first thing to do when using bracketing is to ensure that you have set the bracket step S...

Отзывы: