Bowens BW-3010 Скачать руководство пользователя страница 7

- 7 - 

General Features 

The DUO 4800 Pack has been designed to produce the most compact, powerful, 

versatile and easy to use flash source available today.  Features include: 

z

  Two independent Channels, each having a Quad style head socket, ‘FLASH’ 

Variator, Modelling ‘LAMP’ Variator and Modelling ‘LAMP’ Control switch. 

z

  An ‘ISOLATE’ mode which provides the two independently controlled Channels 

with half the total flash capacity of the Pack each. 

z

  A ‘COMBINE’ mode which provides the total flash capacity of the Pack available 

from the channel A socket, or half the total pack power available from both 
channels, with a common set of controls. 

z

  Modelling ‘LAMP’ Variator and Modelling ‘LAMP’ Controls independent of Flash 

controls. 

z

  Digital ‘POWER’ display of the selected total Pack flash capacity and a visible 

‘READY’ indication. 

z

  Built in, sensitive ‘SLAVE’ Photocell with ON/OFF switch. 

z

  AUDIBLE ‘READY’ Sounder with ON/OFF switch to give audible indication of 

when the Pack is ready to fire. 

z

  A built in fan which cools the unit continuously as long as the mains is supplied. 

z

  Overheat protection which protects the unit in the event of extended periods of 

continuous flashing and also in the unlikely event of failure of the cooling fan. 

z

  EMC (Electro-Magnetic Compatibility) filters fitted. 

Power Supply Connection 

z

  The Packs are designed to operate on an alternating current (AC) supply of 200 to 

253 Volts, 50 Hz.  The Packs must NEVER be connected to any direct current 
(DC) supply. 

z

  The Packs conform to current standards which require connection to a properly 

grounded power supply.  The 3 core power cord supplied with each Pack will be 
colour coded as follows: 

 Live 

(L): 

 Brown 

 Neutral 

(N): 

 Blue 

 Earth 

(E): 

 Green/Yellow 

z

  It is essential that all 3 wires are connected to the correct plug pins in accordance 

with the above colour code and that the cable is securely clamped in the supply 
plug. 

AC Power Switch 

z

  The AC Power switch connects power to both the flash and modelling circuits. 

The switch is illuminated green when ‘ON’. 

z

  ALWAYS switch ‘OFF’ the unit before plugging or unplugging Flash Heads, 

changing fuses or modelling lamps. 

Circuit Protection 

z

  Protection of the Modelling circuitry is by means of a 20mm fuse mounted on the 

control panel of the Pack.  The fuse is rated at 15 Amp (T) and should never be 
replaced with a fuse of a different type or rating. 

Содержание BW-3010

Страница 1: ...DUO 4800 PACK OPERATING INSTRUCTIONS BW 3010...

Страница 2: ...IA THE PROTECTIVE EARTH CONDUCTOR OF THE POWER CORD DO NOT REMOVE THE EQUIPMENT SCREWS OR COVERS NO USER SERVICEABLE PARTS INSIDE DANGEROUS VOLTAGES ARE PRESENT EVEN AFTER SWITCHING OFF THE PACK SHOUL...

Страница 3: ...S 7 POWER SUPPLY CONNECTION 7 AC POWER SWITCH 7 CIRCUIT PROTECTION 7 FAST SLOW CHARGE SWITCH 8 FLASH HEADS 8 FLASH POWER SELECTION INDICATION 8 MODELLING LAMP OUTPUT CONTROL 9 OPEN FLASH 9 EXTERNAL SY...

Страница 4: ...4 Figure 1 DUO 4800 Control Panel Layout...

Страница 5: ...visible READY Indicator 9 Channel A Modelling LAMP Power Variator 10 Channel B Modelling LAMP Power Variator 11 Channel A Modelling LAMP Switch CONTINUOUS OFF INTERMITTENT 12 Channel B Modelling LAMP...

Страница 6: ...he equipment with damaged cables Have them replaced as soon as possible NEVER attempt to repair them yourself z NEVER use the Pack or Flash Heads in an environment where moisture water vapour or infla...

Страница 7: ...rotection which protects the unit in the event of extended periods of continuous flashing and also in the unlikely event of failure of the cooling fan z EMC Electro Magnetic Compatibility filters fitt...

Страница 8: ...be used 3 It is only possible to use a single 3k QUAD head in socket B on the 4800 pack as the pack will not charge when a single 3k QUAD head is plugged into socket A z For detailed information on th...

Страница 9: ...Channel B switches and variators have independent control over the Modelling Lamp in their respective Channel z Set the appropriate Modelling Lamp switch to the centre position to switch the Modellin...

Страница 10: ...the SOUNDER switch to ON to enable the Sounder The Red indicator LED below the switch will be lit when the Sounder is in operation When the Sounder is switched ON it will give a short beep when the Pa...

Страница 11: ...eriod Pack NOT READY AC Power Switch neon AND one or more other indicators on the control panel are lit and the top panel Circuit Breaker has operated Pack previously under very heavy use with fast re...

Страница 12: ...Duo Lite Head BW 3015 4800Ws 1 Head 600Ws 1 Head 4800Ws 2 Heads 300Ws 2 Heads 1 322 second 1 243 second 1 555 second 1 417 second SUPPLY VOLTAGE 200 to 253 Volts 50Hz FLASH VOLTAGE STABILISATION 1 RE...

Страница 13: ...include a full range of Stands Umbrellas Reflectors and Register Wafers etc For details of all related products please contact your local distributor Due to our policy of constant product improvement...

Страница 14: ...FITTED SOCKET 1 SOCKET 2 1 4800W s 1 2400W s 2 2400W s 2400W s ISOLATE MODE The TOTAL flash output is split asymmetrically between the two Channels dependent upon the POWER switch VARIATOR A and VARI...

Страница 15: ...15 DUO 4800 INSTRUCTIONS BWL 0277 Issue 1 5 5 99 BOWENS INTERNATIONAL LIMITED 355 OLD ROAD CLACTON ON SEA ESSEX C015 3RH ENGLAND Tel 44 0 1255 422807 Fax 44 0 1255 436342...

Отзывы: