Page 42
9e1034
7.4 SERVICE AND MAINTENANCE
6
HandyFloor
Every
m
il
king
Daily
50 hrs
or
week
ly
250 hrs
or
monthly
1500
hrs
or
every
6
months
3000
hrs
or
ann
ually
HandyFloor lifting
unit
Check spindle
motor for external damage
and leaks
Ɣ
Check all plastic wheels for play
2nd
year
Check adjusting sheath for wear
Ɣ
Check chain for wear and corrosion
Ɣ
Check whether chains are slack¹
Ɣ
Retighten a
ll bolts
Ɣ
HandyFloor frame
Wash/clean t
he floor
Ɣ
Check p
lastic gratings for cracks
Cracked gratings must be replaced
Ɣ
Retighten all bolts
Ɣ
HandyFloor control
unit
/operation
Calibration
Ɣ
Open control unit and check for moisture
Ɣ
Check
if
rubber caps on the pushbuttons are
tight
Ɣ
The following must be carried out within 1 year of start-up.
•
The floor and the wall brackets must be cleaned.
•
The floor must be calibrated immediately before start of maintenance.
•
Move the floor down approx. 200 mm from its top position.
•
Switch off the power to the control unit.
¹ If some of the chains are “slack”, the floor must be adjusted. Before the chains are adjusted, check whether the
floor can move freely in the guides.
Содержание HandyFloor 2015
Страница 32: ...Page 32 9e1034...
Страница 44: ...Page 44 9e1034...
Страница 49: ...L N L1 F1 F2 N 5 6 7 0 L N 1 2 3 3 4 Page 49 9e1034 9 3 CONTROL UNIT WITH 2 SPINDLE MOTORS...
Страница 50: ...L N F1 F2 F3 N 5 6 7 0 0 L N L N L1 N 1 1 2 2 3 3 3 4 Page 50 9e1034 9 4 CONTROL UNIT WITH 3 SPINDLE MOTORS...
Страница 53: ...Page 53 9e1034 9 6 ELECTRICAL PARTS...
Страница 56: ...Page 56 9e1034...
Страница 57: ......