Botex DPX-1210H NET Скачать руководство пользователя страница 47

 

DPX-1210H NET
(Item no. 469657)

DPX-1210S NET
(Item no. 469658)

Dimmer channels

12

12

Output

16-pin multi-pin

Safety socket

Further information

Technical specifications

 

DPX-1210H NET DPX-1210S NET

47

dimmer pack

Содержание DPX-1210H NET

Страница 1: ...DPX 1210H NET DPX 1210S NET dimmer pack User manual...

Страница 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 27 03 2020 ID 469657_469658...

Страница 3: ...ords 9 2 Safety instructions 11 3 Features 16 4 Installation and starting up 17 5 Connections and controls 19 6 Operating 25 6 1 Main menu 25 6 2 DMX and Art Net settings 27 6 3 Dimmer settings 29 6 4...

Страница 4: ...7 Technical specifications 45 8 Plug and connection assignment 48 9 Protecting the environment 49 Table of contents 4 DPX 1210H NET DPX 1210S NET dimmer pack...

Страница 5: ...DPX 1210H NET DPX 1210S NET 5 dimmer pack...

Страница 6: ...le to all persons using this device If you sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous development W...

Страница 7: ...he search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consulta...

Страница 8: ...ngs for connectors and controls are marked by square brackets and italics Examples VOLUME control Mono button Texts and values displayed on the device are marked by quotation marks and italics Example...

Страница 9: ...rrow Example 1 Switch on the device 2 Press Auto Automatic operation is started 3 Switch off the device 1 3 Symbols and signal words In this section you will find an overview of the meaning of symbols...

Страница 10: ...or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation that can result in material and environmental damage if it is not av...

Страница 11: ...proper and may result in personal injury or property damage No liability will be assumed for damages resulting from improper use This device may be used only by persons with sufficient physical sensor...

Страница 12: ...nit They could swallow the pieces and choke Never let children unattended use electrical devices DANGER Electric shock caused by high voltages inside Within the device there are areas where high volta...

Страница 13: ...fied elec trical personnel in volt free condition Failure to do so may result in electric shock and risk of fire and loss of life By all means you have to observe all electrical safety instructions ap...

Страница 14: ...this user manual Avoid heavy temperature fluctua tions and do not switch the device on immediately after it was exposed to tem perature fluctuations for example after transport at low outside temperat...

Страница 15: ...outlet is protected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly injure the user Unplug the device before electrical storms occur and when...

Страница 16: ...y via buttons and display on the unit n Built in DMX recorder for recording and storing of up to 99 static scenes n Scenes can be played as a chase in a loop with adjustable fade time n Live display f...

Страница 17: ...ate all connections while the device is off Use the shortest possible high quality cables for all connections Take care when running the cables to prevent tripping hazards The device is designed for m...

Страница 18: ...DMX input of the device to the DMX output of a DMX controller or another DMX device Connect the output of the first DMX device to the input of the second one and so on to form a series connection Make...

Страница 19: ...5 Connections and controls Front panel Connections and controls DPX 1210H NET DPX 1210S NET 19 dimmer pack...

Страница 20: ...as soon as the unit is connected to the power supply DMX Control indicator The LED flashes when the device receives a DMX control signal Art Net Control indicator The LED flashes when the device rece...

Страница 21: ...evel decreases the displayed value by one Toggles between the menu items of a menu level increases the displayed value by one 8 ESC Closes an open menu without saving any changes 9 Art Net RJ45 input...

Страница 22: ...Rear panel DPX 1210H NET item no 469657 Connections and controls 22 DPX 1210H NET DPX 1210S NET dimmer pack...

Страница 23: ...Rear panel DPX 1210S NET item no 469658 Connections and controls DPX 1210H NET DPX 1210S NET 23 dimmer pack...

Страница 24: ...put socket 5 pin 12 1CH 6CH 7CH 12CH Dimmer outputs 2 16 pin Harting industrial connectors note the device label when connecting the cables 1CH 12CH Dimmer outputs 12 safety sockets note the device la...

Страница 25: ...ional 2 Switch on the required channels using the assigned circuit breakers 3 To switch off the device pull the mains plug from the 32 A CEE socket 6 1 Main menu 1 Press MENU to activate the main menu...

Страница 26: ...return to display mode After 5 seconds of inactivity the menu is closed and the device automatically returns to display mode In the LOCAL CONTROL and PLAY SCENE submenus the menu remains open even aft...

Страница 27: ...1 255 Sets the ArtNET address for a SubNET Universe 001 255 Sets the ArtNET address for an ArtNET universe The DMX start address is set and assigned to a channel via the ADDRESS menu 1 Press MENU to a...

Страница 28: ...enu for channel selection 7 Press ENTER to activate the Cursor 8 Press to move the cursor between the fields Patch for channel selection and Start for entering the start address 9 Press or repeatedly...

Страница 29: ...for an ArtNET universe and confirm with ENTER 5 Press or repeatedly until the display shows the desired address for the subnet or the Art Net universe display shows 000 255 and confirm with ENTER The...

Страница 30: ...89012 whose parameters you want to change 4 Press or repeatedly until the display shows the desired value for the selected dimmer channel 5 Press ESC to exit the menu and return to display mode The se...

Страница 31: ...ears on the display and confirm with ENTER The cursor flashes at channel one 3 Press to move the cursor to the desired channel 4 Press or repeatedly until the display shows the desired dimmer curve di...

Страница 32: ...r repeatedly until the SCENE REC submenu is shown on the display 3 Press to select the Copy submenu and confirm with ENTER 4 Press or repeatedly until the display shows the number under which you want...

Страница 33: ...edly until the SCENE REC submenu is shown on the display 3 Press to select the Assign submenu and confirm with ENTER 4 Press to move the cursor to the number of the channel whose value you want to cha...

Страница 34: ...lected scene in an endless loop Fad1s Fad9s Sets the fade time from 1 to 9 seconds E01 E99 Selects the final scene 01 to 99 Playback pauses Playback is running Scene Sc01 Sc99 Selects the start scene...

Страница 35: ...o move the cursor to the display mode options 6 Press or to select the play mode Once single play or Loop loop playback 7 Press and then press or to select the fade time Fad1s Fad9s 8 Press and then p...

Страница 36: ...s ENTER The selected scene is played on the set channel 6 To exit the menu without making changes press ESC 6 5 General Settings Menu level 1 Menu level 2 Menu level 3 Function SETUP Protocol Assign D...

Страница 37: ...g is retained Off After 10min The device is blacked out after 10 minutes ArtNet fail DMX The control pro tocol DMX gets acti vated GoScene The scene selected in this setting is played DMX Failed Off T...

Страница 38: ...ut after 10 minutes DMX fail ArtNet The control pro tocol ArtNET gets activated GoScene The scene selected in this setting is played Fan Cooling Normal The fan runs in Nor mal mode The device is kept...

Страница 39: ...t max imum speed Default Confirm Resets the device to factory defaults The control protocol is selected via the SETUP Protocol Assign menu 1 Press MENU to activate the main menu 2 Press or repeatedly...

Страница 40: ...e main menu 2 Press or repeatedly until the SETUP submenu is shown on the display 3 Press to select the ArtNET Failed submenu and confirm with ENTER 4 Press or to select the desired option for the beh...

Страница 41: ...4 Press or to select the desired option for the behaviour of the device in the event of ArtNET control failure 5 If you have chosen the GoScene option press to activate the cursor and use or to select...

Страница 42: ...ess ENTER to confirm the selection The selected settings are adopted 6 To exit the menu without making changes press ESC The SETUP Factory Default menu is used to reset the device to factory defaults...

Страница 43: ...Function INFORMATION Software Version Indicates the software ver sion used Temperature Displays the device tempera ture for dimmer channels 1 to 6 and 7 to 12 The INFORMATION menu is used to call up...

Страница 44: ...oftware version of the device is displayed 4 Press to select the Temperature submenu and confirm with ENTER The device temperature for dimmers 1 to 6 display shows L and dimmer 7 to 12 display shows R...

Страница 45: ...5 pin XLR socket 1 Art Net via RJ45 socket Output connections Voltage supply 2 Harting industrial connectors 16 pin 12 safety sockets with hinged lid Signal output 1 DMX 512 via 3 pin XLR socket 1 DMX...

Страница 46: ...nnel 2 3 kW Protection class IP20 Mounting properties 19 inch 2 RU 19 inch 2 RU Installation depth 380 mm Installation depth 360 mm Dimensions W H D 482 mm 89 mm 379 mm 483 mm 133 mm 377 mm Weight 15...

Страница 47: ...1210H NET Item no 469657 DPX 1210S NET Item no 469658 Dimmer channels 12 12 Output 16 pin multi pin Safety socket Further information Technical specifications DPX 1210H NET DPX 1210S NET 47 dimmer pa...

Страница 48: ...oyed DMX controller a short circuit or just a not working light show Three and five pin XLR sockets serve as DMX outputs a three or five pin XLR connector optionally serves as DMX input The figure bel...

Страница 49: ...arkings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal household waste...

Страница 50: ...Notes 50 DPX 1210H NET DPX 1210S NET dimmer pack...

Страница 51: ......

Страница 52: ...Musikhaus Thomann Hans Thomann Stra e 1 96138 Burgebrach Germany www thomann de...

Отзывы: