background image

  Changing Pump Valves 

The Bosworth Company 

Doc M-09-33-111516 

 

Each pump body in the Guzzler G2 

SapPuller 

pump features a pair of 

valves (a total of 4 for the pump).  A valve is fastened between the 
pump body and each of its inlet and outlet ports. 

(Figure 14)

  

 
 
Valves are typically replaced in pairs; i.e., the inlet and outlet valve 
of a given pump body are replaced at the same 

Ɵ

me.   

 
When replacing a pair of pump valves, it is best that 

only one valve 

is removed and replaced before a

Ʃ

emp

Ɵ

ng to remove and replace 

the other valve.

 

 

Removing the Valve 

1.  Disconnect the power. 

2.  Place the pump assembly with the motor 

in a ver

Ɵ

cal posi

Ɵ

on. 

3.  Remove the inlet manifold by loosening 

the hose clamps holding the manifold to 

the pump 

fl

anges. 

4.  Remove the 6 screws holding the inlet 

fl

ange to the pump body.  

(Figure 15)

  The umbrella 

valve is located between this 

fl

ange and the pump 

body.   

Note the orienta

Ɵ

on of 

the umbrella valve.  The 

valve stem points oppo-

site to the direc

Ɵ

on of 

fl

uid 

fl

ow.  

(Figure 16)

 

                                       Umbrella valve stem points in opposite direc

Ɵ

on to 

fl

uid 

fl

ow. 

Figure 16 

Loca

Ɵ

on of inlet and outlet valves on pump 

body 

Figure 14 

Remove 6 screws holding 

fl

ange to pump body. 

Figure 15 

Содержание Guzzler G2-0503N

Страница 1: ...Doc M PR 09 33 111516 O M G G2 0503N 12 VDC S P D D P Copyright 2016 The Bosworth Company...

Страница 2: ...Guzzler G2 0503N SapPuller Pump Exploded View 1 Doc M 09 33 111516 The Bosworth Company 1M 2M 7D 21 6B 7G 10 7E 6B 10 10 10...

Страница 3: ...Housing 7E Housing Cover Plate 7G Pump Support Bracket Leg 10 Coupler Nut 4 Nylon Sleeve 4 12 Misc Hardware 10 24 Screws Nuts 10 connects 1 pump body to housing 12C Diaphragm Screw 13 Diaphragm FDA B...

Страница 4: ...ed to your pump with the inlet end facing in either of these two possible direc ons Choose an orienta on for your inlet and outlet mani folds that best suits the orienta on of your incoming and outgoi...

Страница 5: ...equiring recharging The motor is rated for 14 0 amps at full load The Guzzler G2 SapPuller pump is capable of developing 22 in of Hg vacuum 0 7 bar but it is a low cfm cubic feet of air per minute pum...

Страница 6: ...of its normal volume It will be apparent when a diaphragm fails be cause sap will leak from the diaphragm into the housing of the pump draining out through either of the two drain holes at the bottom...

Страница 7: ...n a plas c support plate to the diaphragm 6 Pull the diaphragm out to its maximum travel Re move the slo ed head screw washer bu on and dia phragm from the plas c clevis Figure 9 Note If you plan to c...

Страница 8: ...the holes in the housing Figure 12 Be sure that the dia phragm s outer lip sits in the groove running around the circumference of the pump body Figure 13 Note Ensure the pump body is installed in the...

Страница 9: ...o remove and replace the other valve Removing the Valve 1 Disconnect the power 2 Place the pump assembly with the motor in a ver cal posi on 3 Remove the inlet manifold by loosening the hose clamps ho...

Страница 10: ...e inspected and cleaned old valve between the pump body and the pump inlet flange taking care that the flat side of the valve is facing toward the pump body and the O rings are in place Figure 16 Fast...