Changing Pump Valves
The Bosworth Company
Doc M-09-33-111516
Each pump body in the Guzzler G2
SapPuller
pump features a pair of
valves (a total of 4 for the pump). A valve is fastened between the
pump body and each of its inlet and outlet ports.
(Figure 14)
Valves are typically replaced in pairs; i.e., the inlet and outlet valve
of a given pump body are replaced at the same
Ɵ
me.
When replacing a pair of pump valves, it is best that
only one valve
is removed and replaced before a
Ʃ
emp
Ɵ
ng to remove and replace
the other valve.
Removing the Valve
1. Disconnect the power.
2. Place the pump assembly with the motor
in a ver
Ɵ
cal posi
Ɵ
on.
3. Remove the inlet manifold by loosening
the hose clamps holding the manifold to
the pump
fl
anges.
4. Remove the 6 screws holding the inlet
fl
ange to the pump body.
(Figure 15)
The umbrella
valve is located between this
fl
ange and the pump
body.
Note the orienta
Ɵ
on of
the umbrella valve. The
valve stem points oppo-
site to the direc
Ɵ
on of
fl
uid
fl
ow.
(Figure 16)
Umbrella valve stem points in opposite direc
Ɵ
on to
fl
uid
fl
ow.
Figure 16
8
Loca
Ɵ
on of inlet and outlet valves on pump
body
Figure 14
Remove 6 screws holding
fl
ange to pump body.