RBS2C-A
18
1.
Be sure Segments 2 and 3 of DIP Switch S3 are in ON (Closed) position.
2.
If the motor is shunt-wound, run it at rated base speed. If the motor is a permanent-magnet type, run it
about 1/3 speed.
3.
Turn the IR/TACH potentiometer clockwise
slowly
until motor speed becomes unstable. Then turn the
potentiometer counterclockwise until motor speed stabilizes.
MAXIMUM SPEED (ARMATURE FEEDBACK)
The MAX SPD potentiometer adjusts maximum speed by setting maximum armature voltage. The voltage
range is from 50% to 100% of rated armature voltage. If the controller is programmed for tachometer feedback, the
MAX SPD potentiometer sets the armature backup voltage.
1.
Be sure Segments 2 and 3 of DIP Switch S3 are in ON (Closed) position.
2.
Turn the MAX SPD potentiometer fully clockwise (100%). This setting provides 90 VDC armature volt-
age with a 115 VAC line, or 180 VDC armature voltage with a 230 VAC line.
3.
Run the motor at maximum speed, and turn the MAX SPD potentiometer counterclockwise for the desired
maximum speed.
NOTE: If the MAX SPD potentiometer is turned too far counterclockwise, speed instability may occur.
MAXIMUM SPEED (TACHOMETER FEEDBACK)
1.
Be sure Segments 2 and 3 of DIP Switch S3 are in OFF (Open) position.
2.
Set Segment 1 of DIP Switch S3 for the expected tachometer generator speed at maximum speed, as fol-
lows:
3.
Turn the IR/TACH potentiometer fully counterclockwise (0%). This setting provides maximum motor
speed.
4.
Be sure the MAX SPD potentiometer has been adjusted correctly.
5.
Run the motor at maximum speed, and start turning the IR/TACH potentiometer clockwise until motor
speed increases above desired speed. Continue turning the potentiometer clockwise until motor speed
decreases to desired speed.
SEGMENT 1 POSITION
TACH VOLTAGE
ON (Closed)
8V - 30V
OFF (Open)
31V - 175V
®