ACE10UG
5
When power is applied:
WARNING
●
Do not install or remove input or output controller connections when the power
supply is turned on. Otherwise, the controller may be damaged due to the surge peak
caused by the application or removal of power.
●
When momentary power loss is longer than 2 seconds (the larger the horsepower, the
the longer the time), the controller does not have enough storage power to retain control.
Therefore, when power is reapplied, the operation of the controller is based on the
setup of F_10 and the condition of an external switch (FWD/REV button).
This is considered to be a restart in the following paragraphs.
●
When the momentary power loss is short, the controller still has enough storage power
to retain control. Therefore, when power is reapplied, the controller will automatically
start operation again, depending on the setup of F_23.
When the controller restarts, the operation is based on the setup of F_10,
and the condition of an external switch (FWD/REV button). The restart operation
is irrelevant with F_23/F_24.
(1) When F_10 = 0, the controller will not start after restart.
(2) When F_10 = 1 and the external switch (FWD/REV button) is OFF, the controller will
not start after a restart command.
(3) When F_10 = 1 and the external switch (FWD/REV button) is ON, the controller will
start automatically after a restart command. For safety reasons, turn off the external
switch (FWD/REV button) after a power loss to avoid possible damage to the machine
and personal injury after sudden regeneration of power.
During Operation:
WARNING
Do not use a separate device to switch the motor ON or OFF during operation. Otherwise,
the controller may experience an over-current breakdown.
WARNING
●
Do not remove the controller front cover when the power is ON to avoid personal
injury caused by electrical shock.
●
When the automatic restart function is enabled, the motor and machinery will restart
automatically.
■
!
■
!
■
!