background image

-4-

MIII TOOL SPECIFICATIONS

OPERATION

All dimentions in inches unless otherwise specified

FASTENER SPECIFICATIONS:

TOOL AIR FITTING:

This tool uses a 3/8” N.P.T. male plug.  The inside diameter should be .275” (7mm) or larger. The fitting
must be capable of discharging tool air pressure when disconnected from the air supply.

OPERATING PRESSURE:

70 to 90 p.s.i.g. (4.9 to 6.3 kg/cm2).  Select the operating pressure within this range for best fastener
performance.  DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE.

AIR CONSUMPTION:

The MIII requires 4.2 cubic feet per minute (221 liters per minute) of free air to operate at the 
rate of 60 fasteners per minute, at 80 p.s.i. (5.6 kg/cm2).  Take the actual rate at which the tool will be run
to determine the amount of air required.  For instance, if your fastener usage averages 30 fasteners per
minute, you need 50% of the tool’s c.f.m. of free air which is required to operate the tool at 60 fasteners
per minute.

MODEL

LENGTH

HEIGHT

WIDTH

WEIGHT

MIIIFS

17-1/4” (438mm)

11-1/2” (292mm)

3-1/8” (80mm)

11.2lbs (5.1kg)

MIIIFN

17-1/4” (438mm)

11-1/2” (292mm)

3-1/8” (80mm)

11.2lbs (5.1kg)

MODEL

FASTENER

CROWN WIDTH

WIRE SIZE

MAX LENGTH

MIIIFS

BCS1500

1/2” (13mm)

15-1/2 Ga.

2” (50mm)

MIIIFN

FLN-200

-

-

2” (50mm)

Caution Regarding Use of this Tool to Install Pre-finished Flooring

This MarkIII Flooring Tool was designed for use in installing unfinished hardwood flooring. It can be used to
install pre-finished flooring however caution must be used to ensure that the finish is not damaged by the tool.
It is recommended that the tool be tested on a sample section to be certain that the tool and technique of use
do not leave marks on the finish. This procedure should be followed before each job due to variations in flooring
and tool condition.

Содержание MIIIFN

Страница 1: ...RIBUTOR ANTES DE OPERAR ESTA HERRAMIENTA TODOS LOS OPERADORES DEBERÁN ESTUDIAR ESTE MANUAL PARA PODER COMPRENDER Y SEGUIR LAS ADVERTENCIAS SOBRE SEGURIDAD Y LAS INSTRUCCIONES MANTENGA ESTAS INSTRUCCIONES CON LA HERRAMIENTA PARA FUTURA REFERENCIA SI TIENE ALGUNA DUDA COMUNÍQUESE CON SU REPRESENTANTE DE BOSTITCH O CON SU DISTRIBUIDOR LIRE ATTENTIVEMENT LE PRÉSENT MANUEL AVANT D UTILISER L APPAREIL P...

Страница 2: ...ed is free from defects in material and workmanship and agrees to repair or replace at Bostitch s option any defective Bostitch branded pneumatic stapler or nailer for a period of seven 7 years from date of purchase one 1 year from the date of purchase for compressors and tools used in production applications Warranty is not transferable Proof of purchase date required This warranty covers only da...

Страница 3: ...ol 3 When clearing a jam 4 When tool is not in use 5 When moving to a different work area as accidental actuation may occur possibly causing injury LOADING TOOL When loading tool 1 Never place a hand or any part of body in fastener discharge area of tool 2 Never point tool at anyone 3 Do not pull the trigger or depress the trip as accidental actuation may occur possibly causing injury OPERATION Al...

Страница 4: ...stance if your fastener usage averages 30 fasteners per minute you need 50 of the tool s c f m of free air which is required to operate the tool at 60 fasteners per minute MODEL LENGTH HEIGHT WIDTH WEIGHT MIIIFS 17 1 4 438mm 11 1 2 292mm 3 1 8 80mm 11 2lbs 5 1kg MIIIFN 17 1 4 438mm 11 1 2 292mm 3 1 8 80mm 11 2lbs 5 1kg MODEL FASTENER CROWN WIDTH WIRE SIZE MAX LENGTH MIIIFS BCS1500 1 2 13mm 15 1 2 ...

Страница 5: ...perating pressure for the tool FILTER Dirt and water in the air supply are major causes of wear in pneumatic tools A filter will help to get the best performance and minimum wear from the tool The filter must have adequate flow capacity for the specific installation The filter has to be kept clean to be effective in providing clean compressed air to the tool Consult the manufacturer s instructions...

Страница 6: ...DE should ALWAYS be worn by the operator and others in the work area when connecting to air supply loading operating or servicing this tool Eye protection is required to guard against flying fasteners and debris which could cause severe eye injury The employer and or user must ensure that proper eye protection is worn Eye protection equipment must conform to the requirements of the American Nation...

Страница 7: ...xtended beyond its length the end will come off the roller and the spring will roll up with a snap with a chance of pinching your hand Also the edges of the spring are very thin and could cut Care must also be taken to insure no permanent kinks are put in the spring as this will reduce the springs force REPLACEMENT PARTS BOSTITCH replacement parts are recommended Do not use modified parts or parts...

Страница 8: ...ly seated Reverse these instructions to reassemble e Assemble plunger flush with end of piston stem TO REPLACE PILOTED VALVE SEALS 1 Remove exhaust deflectors and four hex socket head cap screws holding cap to cylinder Remove cap exposing the poppet piston and piloted valve 2 Remove gasket piloted valve seat piloted valve spring and O rings 3 Clean all O ring grooves Lubricate new O rings and asse...

Страница 9: ...driver to clean Cylinder sleeve not seated correctlyon bottom bumper Disassemble to correct Head valve dry Disassemble lubricate Air pressure too low Check air supply equipment Skipping fasteners intermittent feed Worn bumper Replace bumper Tar dirt in driver channel Disassemble and clean nose and driver Air restriction inadequate air flow through quick disconnect socket and plug Replace quick dis...

Страница 10: ... 10 ACCESSORIES AVAILABLE BC1297 Handle short 105043 Bumper 105056 Spacer 5 16 Special 167193 Mallet Graphite MIIIFOOT KIT Prefinished Flooring Kit MIIIFOOT KIT ...