background image

Attachments and Accessories:

For any attachment or accessory you will be using with this compressor, the maximum
allowable recommended pressure should be clearly marked on the product or should be
clearly noted within the operations manual. Exceeding the pressure rating of these
attachments (including, but not limited to:air tools, air operated accessories, spray guns, air
hose, air hose connections, tires and other inflatables) could cause them to fly apart or
explode and could result in serious injury.  
• Never exceed the maximum allowable pressure recommended by the manufacturer of any

attachment or accessory you use with this compressor.

Personal Protection:

The employer and/or user must ensure that proper eye protection is worn.  Eye protection
equipment must conform to the requirements with the applicable parts of AS/NZS 1337.1:2010
and AS/NZS 1337.6:2007. 

NOTICE!:

Non-side shielded spectacles and face shields alone do not provide adequate

protection. 

Additional Safety Protection will be required in some environments. For

example, the working area may include exposure to noise level which can lead to hearing
damage.  The employer and user must ensure that any necessary hearing protection is
provided and used by the operator and others in the work area.  Some environments will
require the use of head protection equipment. When required, the employer and user must
ensure that head protection conforming to the applicable parts of AS 1800 and AS/NZS
1801:1998.
• Always wear eye protection.
• Wear proper hearing and head protection.
• Compressed air blast must never be aimed at anyone.  Compressed air can cause bodily

injury and can propel loose particles and small objects at high speed.

• Keep children away from area of operation.

Transporting:

Always disconnect the air compressor before transporting. Use the handle to move the
compressor.  Do not drag or pull the compressor by the power cord or air hose.  

Air Tank:

Due to condensation associated with the process of compressing air, moisture will build up
inside your compressor’s air tank.  Drain tank of moisture daily (See General Maintenance).
Failure to drain moisture from the tank properly could lead to the formation of rust and
thinning of the steel tank.

WARNING:

FAILURE TO REGULARLY DRAIN TANK MAY CAUSE TANK CORROSION AND

RISK OF TANK EXPLOSION, RESULTING IN SERIOUS INJURY.  TO AVOID RISK OF TANK
FAILURE DURING USE, DRAIN TANK AFTER EACH USE OR EVERY FOUR HOURS OF
OPERATION TO PREVENT CONDENSATION BUILD-UP AND TANK CORROSION.

WARNING:

DO NOT PERFORM WELDING OR REPAIR OPERATIONS ON THE AIR TANK OF

THIS COMPRESSOR.  WELDING ON THE AIR COMPRESSOR TANK CAN SEVERELY IMPAIR
TANK STRENGTH AND CAUSE AN EXTREMELY HAZARDOUS CONDITION.  WELDING ON
THE TANK IN ANY MANNER WILL VOID THE WARRANTY.

3

PROOF

Содержание BTFP02000

Страница 1: ...LOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE IF YOU HAVE ANY QUESTIONS CONTACT YOUR BOSTITCH REPRESENTATIVE OR DISTRIBUTOR N199753 07 2012 BTFP02000 AIR COMPRESSOR OPERATION AND MAINTENANCE MANUAL BOSTITCH FASTENING SYSTEMS P R O O F ...

Страница 2: ...information that if not followed correctly could result in damage to equipment INDEX Introduction 2 Rules for Safe Operation 2 4 Electrical Grounding Instructions 4 5 Specifications 5 Features 6 Operation Instructions 7 General Maintenance 7 Warranty 7 9 Trouble Shooting guide 10 NOTE Bostitch compressors have been engineered to provide excellent customer satisfaction and are designed to achieve m...

Страница 3: ...nts will require the use of head protection equipment When required the employer and user must ensure that head protection conforming to the applicable parts of AS 1800 and AS NZS 1801 1998 Always wear eye protection Wear proper hearing and head protection Compressed air blast must never be aimed at anyone Compressed air can cause bodily injury and can propel loose particles and small objects at h...

Страница 4: ...operly installed and grounded in accordance with all local codes and ordinances DANGER IMPROPER INSTALLATION OF THE GROUNDING PLUG CAN RESULT IN A RISK Check with a qualified electrician or serviceman if the grounding instructions are not completely understood or if there is doubt as to whether this product is properly grounded Do not modify the plug provided If the supplied plug does not fit the ...

Страница 5: ...xtension cord must be used use these guidelines Distance Needed Recommended Conductor Size Less than 10 m 1 mm 10 A 10 15 m 1 5 mm 15 A Greater than 15 m Not Recommended BTFP02000 SPECIFICATIONS Motor 1 3 running HP 240 V 1 ph 50 Hz Fuse Requirement 10 Amp minimum Operating Pressure 0 10 BAR 0 150 PSI Safety Valve Setting 11 BAR 165 PSI Air Delivery 69 4 LTR MIN 6 2 BAR 2 5 CFM 90 PSI Air Displace...

Страница 6: ...e Gauge The tank pressure gauge indicates the air pressure that is present in the tank in BAR C Regulated Pressure Gauge The regulated pressure gauge indicates the amount of pressure that is allowed into the discharge line according to the setting of the regulator D Regulator Knob The regulator knob is used to adjust the air pressure that is available at the discharge line The discharge air pressu...

Страница 7: ...ect all accessories and attachments from the unit and disconnect the compressor from the electrical source When replacing parts only use Genuine BOSTITCH replacement parts Notice This compressor is equipped with an oil free pump There is no oil to replace or check Draining Tank Twist Style Drain Cock 1 Verify that the compressor is turned Off 2 Holding the handle tilt the compressor toward the dra...

Страница 8: ...ptions a The warranty against defects in materials and workmanship for Stanley Products with electrical or electronic components is twelve 12 months b Sidchrome and Facom airtools are warranted for two 2 years from the date of purchase excluding normally wearing parts such as vanes gaskets and o rings c Sidchrome and Facom electronic instruments are warranted for six 6 months from the date of purc...

Страница 9: ...im is as follows a Any product subject to a warranty claim should be returned to the place of purchase for assessment by a Stanley Australia distributor or representative You are responsible for returning the product to the place of purchase unless the cost of returning removing or transporting the product is significant in which case you should contact Stanley Australia to make alternative arrang...

Страница 10: ...pically temperatures below freezing then try restarting Air leaks at fittings Fittings loose Tighten fitting Check with soapy water DO NOT OVER TIGHTEN Air leak at pressure switch Clogged check valve STOP USING COMPRESSOR CONTACT NEARST BOSTITCH AUTHORIZED REPAIR CENTER Unit will not build pressure Application requires excessive air demand Reduce demand on compressor Loose head STOP USING COMPRESS...

Страница 11: ...11 welds WARNING DO NOT DRILL INTO WELD OR OTHERWISE MODIFY AIR TANK DAMAGED OR MODIFIED TANKS CAN RUPTURE REPLACE TANK IMMEDIATELY NOTES P R O O F ...

Страница 12: ...12 P R O O F ...

Отзывы: