![Bossini Dream-FLAT Light H37 Series Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/bossini/dream-flat-light-h37-series/dream-flat-light-h37-series_installation-and-care-instructions_2794829016.webp)
16
GB
PLUMBING EQUIPMENT DREAM 12/10/8 LED
Water line:
arrange your shower box with the water supply line and coupling for the showerhead. The
coupling must be above the ceiling. (Fig. 1). 20 litres of water per minute is enough for the Dream showerhead
to work. In fact, the showerhead, which is installed parallel to the floor, supplies a “free falling” stream of
water like soft rain. Make sure that the faucet supplies at least 25 litres of water per minute. Naturally, the
higher the flow rate of the faucet, the better the showerhead will work. Also make sure that the hot water
heater supplies enough hot water for proper functioning.
Plumbing equipment DREAM 4 LED
16 litres of water per minute is enough for the Dream showerhead to work. Make sure that the faucet supplies
at least 20 litres of water per minute.
ELECTRICAL EQUIPMENT
• Power connection:
arrange your shower box with the electrical connection for the showerhead LED
lights, placing it above the false ceiling (Fig. 1). Warning: The electrician must use a power cable thatis two-
pole, 1 mm
2
size, outside diameter between 5 and 13 mm.
•The transformer 7V ~ / 230V ~ – 50/60 Hz must be installed outside the shower box in a safe place (Fig. 1).
Electrical equipment - Technical specifications
1. Electric connection..........................
220/230V ~ – 50/60 Hz - max 20w
Absorbed electricity 0,1A
class of protection II
2. Electric cable....................................
bipolar, 1 mm² size, outside diameter
5 mm to 13 mm (supplied by customer)
3. Dream Rect. lights 500×400 mm/ 570×470 mm..............
12 low voltage LEDs
Dream Rect. lights 400×300 mm/ 470×370 mm...............
4 low voltage LEDs
4. Dream Cube lights 400×400 mm/ 470×470 mm.............
10 low voltage LEDs
Dream Cube lights 300×300 mm/ 370×370 mm..............
4 low voltage LEDs
5. Dream OKI lights, 400 mm dia./ 470 mm dia....................
8 low voltage LEDs
Dream OKI lights, 300 mm dia./ 370 mm dia.....................
4 low voltage LEDs
6. Safety Transformer..................................................................
7V ~/ 230V~ – 50/60 Hz to be
installed outside the safety area (in
compliance with standard DIN VDE 0100,
part 107 – according to prescription CEI 64/8)
7. Grade of protection ............................................................
IP x 5 (excluding transformer)
8. Safety mark..........................................................................
CE
The electrical systems must be carried out by a qualified technician in accordance with the national and
international laws in force.
Turning the LED lights on
LEDs are devices that generate monochromatic light. For them to work properly, they need only a small
amount of power supply and voltage and therefore use little energy and run on low temperatures. The LEDs
are activated when the faucet is turned on, using the stream of water through the Flow switch (5).
FALSE CEILING
•Once the electrical and hydraulic systems are hooked up, realise the false ceiling with suitable reinforcement,
as when mounting a chandelier, and make sure it is perfectly level.
•Keep a distance of at least 12 cm between the ceiling and the false ceiling (Fig.1). Position the template, mark
with a pencil the 6 attachment holes and the central beak-through that will house the electrical and hydraulic
parts of the showerhead (Fig.2).
•Make the 6 attachment holes having a 10 mm diameter
• Make the beak-through (Fig.3)
•Insert the 6 expansion screws and make sure that they are placed accurately (Fig.4).
SHOWERHEAD INSTALLATION
•Insert the quick disconnect coupling (4), complete with flow switch (5) to the showerhead, and block the Allen
screws using their wrench (15), (Fig.5).
•Open the bipolar terminal box IP68 (7) and attach the electrical connections that go to the transformer
(Fig.6).
•Connect the bipolar connector sockets (6) (Fig.7).
•Connect one end of the hose (10) to the flow switch (5) and the other end to the water supply line on the wall
(Fig.8). If there is a ½”F wall connection, use the adaptor (14) ½”M × ½”M that is included.
•Lay the showerhead in correspondence of the 6 expansion screws that were previously inserted in the false
!
INSTALLATION AND CARE INSTRUCTIONS