OPTIC REPLACEMENT INSTRUCTIONS

CAUTION:  DISCONNECT the unit from an electrical power source before 
performing any maintenance or cleaning on the unit.

Step 1 – 

Turn “FAN SPEED” switch to the “OFF” position

Step 2 – 

Unplug power cord from the electrical receptacle

Step 3 –

 Using the supplied key, unlock and remove both end panels

Step 4 – 

Remove filter cover plate and filter

Step 5 – 

Remove optic following these instructions:

Caution:  Use clean powder free latex gloves and eye protection when 
handling the optics in this unit

•  

With a firm grip on the upper porcelain end of the optic, use your other hand to 

grip the optic connector..

• 

Gently ‘wiggle’ connector while pulling from the optic base.

•  

Gently pull optic from three lamp supports 

(Do not put any pressure on the 

side of the optic without support)

.

Caution:  Optics contain Mercury.  Dispose of optics in accordance with 
local regulations.  To find out more about local regulations, please visit 
www.lamprecycle.org.

Step 6 – 

Install new optic following these instructions:

 Remove new optic from packaging and gently insert into the three optic clips.

  With a firm grip on the upper porcelain end of the optic, use your other hand to 

grip the optic connector.  

   Gently connect the optic connector to the optic.

Note:  Optic connector is keyed with the optic base and will connect in 

one direction only

 Ensure optic connector and optic base are firmly pressed together.

Step 7 – 

Re-install end panels

Step 8 – 

Re-install filter and filter plate

Step 9 – 

Plug power cord back into the electrical receptacle

Step 10 – 

Test unit for proper operation

Содержание ODOROX

Страница 1: ......

Страница 2: ...ation 1 Contents List 2 Odorox Boss Operational Guidelines 3 Operating The Odorox Boss 4 Care Instructions 5 Optic Replacement Instructions 6 Troubleshooting Guide 7 Specifications And Warranty 8 TABL...

Страница 3: ...chanical adjustment or repair Use generator only for intended use as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons The u...

Страница 4: ...The Odorox Boss Hydroxyl Generator is shipped with the following 1 Odorox Boss Hydroxyl Generator 2 Washable Filter Comes Installed 3 Set of Keys 4 Owner s Manual 5 Warranty Card CONTENTS LIST...

Страница 5: ...to 500 cfm which makes this unit very versatile Turn the fan to low to deodorize small areas such as cars RVs boats bedrooms or offices This setting is also ideal for tenting damaged contents on site...

Страница 6: ...ed on the fan speed can be controlled by turning the FAN SPEED switch clockwise to decrease the speed or counter clockwise to increase the speed PROCESSOR The Boss unit is equipped with two Odorox hyd...

Страница 7: ...be cleaned in the same manner as the exterior with the exception of the optics and optics housing OPTIC CLEANING Cleaning of the Odorox optics is recommended to maintain peak processing efficiency Fin...

Страница 8: ...ently pull optic from three lamp supports Do not put any pressure on the side of the optic without support Caution Optics contain Mercury Dispose of optics in accordance with local regulations To find...

Страница 9: ...N LED will not light up FAN SPEED switch is in the OFF position Turn on FAN SPEED switch to desired air flow setting Green LED has failed Contact local distributor for service Internal component failu...

Страница 10: ...L GENERATING OPTIC BROWN XSA00EW02 2 OPTICS POWER CABLE XSA00EA01 2 BALLAST ASSEMBLY 120 VOLT N Am XSA00EA06 2 BALLAST ASSEMBLY 200 277 VOLT 50 60 Hz INTL EPC IL 021 1 LIGHT MODULE PROTECTED LED 110 1...

Страница 11: ...ributor To find a distributor in your area please visit www Odorox com Odorox Hydroxyl Generators are proudly manufactured in the USA HGI Industries Inc 2055 High Ridge Road Boynton Beach FL 33426 Tol...

Отзывы: