23
309743
Operation
Shutdowns
There are two compressor parameters that are constantly being monitored
and are logged in an event history. If the compressor system reaches a
point outside of the monitored parameters, the compressor will shutdown.
The two compressor shutdowns are:
• Compressor High Temp
• Compressor High Pressure
The system will shutdown if any of these safeties are outside of the
acceptable range during operation. If a shutdown occurs the B-CAN will
force you to acknowledge it by entering a random 4 digit code using buttons 1 through 4. The system will permit you to
reengage up to three times in one hour once parameters return to normal. This is intended to provide some flexibility in
wrapping up current compressor functions until a replacement compressor arrives. The compressor should not be re-
engaged until the cause of the shutdown has been determined and fixed.
Compressor Lockout
If any combination of three shutdowns occur within one hour of compressor operation, the compressor will lock
and must be taken in for service before operation can continue. If a second PTO component is installed, it can
still be used normally providing it is not driven by the compressor system and has its own dedicated PTO
gearbox.
If three shutdowns occur within an hour of compressor operation, the
compressor operation will be locked out and must be serviced before
operation can continue.
Continued operation of compressor system after shutdown will present
conditions that will cause injuries, death, and/or damage to property.
Содержание 8060 UBI
Страница 2: ...309743 ...
Страница 5: ...5 309743 Safety Safety ...
Страница 12: ...12 309743 Safety ...
Страница 13: ...13 309743 Welcome Welcome ...
Страница 15: ...15 309743 Description of Components Description of Components ...
Страница 19: ...19 309743 Operation Operation ...
Страница 26: ...26 309743 Operation ...
Страница 27: ...27 309743 B CAN B CAN ...
Страница 33: ...33 309743 Maintenance Maintenance ...
Страница 38: ...38 309743 Maintenance ...
Страница 39: ...39 309743 Warranty Warranty ...
Страница 57: ...57 309743 5 4 3 5 6 1 2 7 8 OPTIONAL MOUNTING CONFIGURATIONS Drawings B CANAssembly cont ...
Страница 59: ...59 309743 5 4 4 7 3 1 2 6 9 8 9 Drawings AirFilterAssembly cont ...
Страница 67: ...67 309743 Drawings 10G RSC9 CoolerAssembly cont 10 6 1 7 5 6 5 8 4 5 11 9 2 3 ...
Страница 69: ...69 309743 Drawings 14D CoolerAssembly cont 6 6 5 4 11 10 8 9 7 5 5 2 1 3 ...