Boss Hydraulics PE0180 Скачать руководство пользователя страница 12

BM009

12

4. TROUBLESHOOTING

• 

Repair work or troubleshooting must be performed by qualified 

personnel who are familiar with this equipment.

•  Disconnect the power supply before removing the electrical cover. 

Electrical work should be performed by a qualified electrician.

•  Check for system leaks by using a hand pump to apply pressure 

to the suspect area. Watch for leaking fluid and follow it back to 

its source. Never use your hand or other body parts to check for a 

possible leak.

    

    WARNING:

PROBLEM

CAUSE

SOLUTION

Electric motor does 

not run

Unit is not plugged in

Plug in unit

No voltage supply

Check line voltage

Broken lead wire or 

defective power cord/ 

plug

Replace defective parts

Defective motor

Replace or repair motor

Automatic valve 

will not build full 

pressure

Unloading pressure is 

too low

Increase unloading pressure 

per chart, sheet 3 of 4

Defective or oversize 

seat on automatic valve

Replace ball and seat

Electric motor cuts 

out

Extension cord is too 

long and/ or not of 

sufficient gauge

Replace

Faulty motor

Replace and repair

Overheated motor can 

trip circuit breaker in 

mains power panel

Allow motor to cool, reset 

circuit breaker located in 

mains power panel.

    

    IMPORTANT:

•  For a detailed parts list or to contact your local Boss Hydraulics 

Authorised Service Centre

•  Plug the outlet ports of the pump when checking for leakage to 

determine if the leakage is in the pump, in the cylinder, or in the tool.

Содержание PE0180

Страница 1: ...information provided in this manual before using the equipment They are provided for the safety of those operating the equipment and to prevent personal injury and or damage to property when using thi...

Страница 2: ...tor before opening any connections in the system Do not exceed the hydraulic pressure rating noted on the pump name plate or tamper with the internal high pressure relief valve Creating pressure beyon...

Страница 3: ...pressures lower than their rated capacities Should a hydraulic hose rupture burst or need to be disconnected immediately shut off the pump and shift the control valve twice to release pressure Never...

Страница 4: ...load is under operator control at all times and that others are clear of the load WARNING Avoid straight line tubing connections in short runs Straight line runs do not provide for expansion and cont...

Страница 5: ...unsafe operating conditions IMPORTANT Keep the cylinder clean at all times While at a job site when the cylinder is not in use keep the piston rod fully retracted and upside down Always use protectiv...

Страница 6: ...em and obstruct the flow of fluid or cause jamming of precision fit parts 1 SETUP INSTALLATION Inspection Remove all packing materials from the assembled unit Inspect the unit upon arrival The carrier...

Страница 7: ...he pump running at full pressure Never run the motor on long light gauge extension cords Refer to Table 2 Minimum Recommended Gauge Table see page 8 Bleeding Air from the System After all connections...

Страница 8: ...8 m 8 15m 15 30 m 30 46 m 0 25 ft 25 50 ft 50 100 ft 100 150 ft 6 0 75 1 1 5 2 5 18 16 14 12 10 0 75 1 5 2 5 4 18 14 12 10 14 1 2 5 4 6 16 12 10 8 18 1 5 2 5 6 6 14 12 8 8 22 1 5 4 6 10 14 10 8 6 26...

Страница 9: ...ch will automatically return to OFF position when button is released and pump motor will turn off Bleeding Air from the System Cycle the hydraulic system until operation is smooth and consistent Check...

Страница 10: ...essory equipment Bent or damaged couplers or port threads WARNING Disconnect the unit from the power supply before performing maintenance or repair procedures Repairs and maintenance are to be perform...

Страница 11: ...00 F If low temperature requirements are needed use hydraulic fluid 5 1 cSt 100 C 451 cSt 40 C 3 MAINTENANCE CONT Sound Reduction Electric Motor The electric powered hydraulic pump operates in the 67...

Страница 12: ...age Broken lead wire or defective power cord plug Replace defective parts Defective motor Replace or repair motor Automatic valve will not build full pressure Unloading pressure is too low Increase un...

Страница 13: ...ft key s Replace Coupling not fully connected Connect couplings fully Motor rotating in wrong direction Reverse rotation Pump will not build full pressure Faulty pressure gauge Calibrate or replace ga...

Страница 14: ...urate Calibrate gauge Relief valve not properly set Reset the relief valve Automatic valve will not release pressure Sticking piston Remove clean and polish High pressure hydraulic fluid is leaking pa...

Страница 15: ...d DVK1B PE075 2 Way 2 Position Manual DVBB PES075 2 Way 2 Position Solenoid DVGB PED075 4 Way 3 Position Manual DVE1B PEDC075 4 Way 3 Position Manual DVE2C PEDH075 4 Way 3 Position Manual DVF1B PEDS07...

Страница 16: ...BOSS HYDRAULICS Head Office 19 Ricketts Road Mt Waverley VIC 3149 I P 1300 BOSS HYD 1300 267 749 E sales bosshydraulics com au I W www bosshydraulics com au...