26
z
CN6: External Reset Button
PIN
Description
4
3
1
2
1
GND
2
Reset Switch
3
GND
4
GND
4.16 Watchdog Timer
Once the Enable cycle is active a Refresh cycle is requested before the
time-out period. This restarts counting of the WDT period. When the
time counting goes over the period preset of WDT, it will assume that
the program operation is abnormal. A system reset signal will restart
when such error happens.
The following sample programs show how to enable, disable and
refresh the watchdog timer:
W83627HG-AW Watchdog Timer
1. Assembly sample code:
----------------------------------------------------------------
Extended function mode
----------------------------------------------------------------
MOV DX,
2EH
MOV AL,
87H
OUT DX,
AL
OUT DX,
AL
----------------------------------------------------------------
Configure logical device 8
----------------------------------------------------------------
MOV DX,
2EH
MOV AL,
07H
OUT DX,
AL
MOV DX,
2FH
MOV AL,
08H
OUT DX,
AL
MOV DX,
2EH
MOV
AL, 30H ; Enable WDT
OUT DX,
AL
MOV DX,
2FH
MOV AL,
01H
OUT DX,
AL
----------------------------------------------------------------
Configure time mode
----------------------------------------------------------------
MOV DX,
2EH
MOV AL,
F5H
OUT DX,
AL
MOV DX,
2FH
MOV
AL, 00H ; Setup second mode, 08H for minute mode
OUT DX,
AL
Содержание BPF-3215-V
Страница 8: ......
Страница 12: ...4 1 3 Dimensions...
Страница 14: ...6 This page intentionally left blank...
Страница 16: ...8 3 2 Installation SBC 1 Follow the photo instruction install the SBC onto the chassis...
Страница 19: ...11 3 5 Back Cover Installation 1 Follow the photo instruction install the back cover onto the chassis...
Страница 20: ...12 3 6 Wall Mount Kit 1 Follow the photo instruction install the wall mount kit onto the chassis...
Страница 21: ...13 3 7 VESA Mount Metal Stand Kit...
Страница 22: ...14 This page intentionally left blank...
Страница 24: ...16 4 2 Board Layout Top Side Solder Side...
Страница 52: ...44 This page is the blank page...
Страница 65: ...57 Click on Standard Calibration button and follow the five calibrate points to do the calibration...