- 5 -

4.3.2 Parametric query

On the detection interface, you may press

to see all parameters.

4.3.3 Alarm types

Low alarm: Red LED light + “LA” on detection in slow b
vibration

High alarm: Red LED light + “HA” on detection int fast b
vibration

Range alarm: Red LED light + “RA” on detection int fast beeping
+ vibration

Содержание BH-90E

Страница 1: ...BH 90E Portable Gas Detector Operation Manual...

Страница 2: ...rong adaptive ability Being waterproof dustproof explosion proof and easy to use with high reliability the detector is widely used in oil coal municipal construction chemical engineering environmental...

Страница 3: ...eries display sensors chargers 3 Technical Specifications Target gas Combustible gas Range 0 10 000ppm mol mol Sampling method Natural diffusion Alarm point Default Low alarm 500ppm High alarm 2000ppm...

Страница 4: ...f grade Exib IIB T3 Gb Sensor type Imported FIGARO sensor Sensor life 2 years Power supply Rechargeable lithium battery DC3 7V 1800mAH Charging time 6h 8h Continuous working hours No less than 8 hour...

Страница 5: ...Bosean Electronic Technology Co Ltd www bosean com 4 see below 4 2 Self check After self check is done the device enters into detection interface see below 4 3 Detection interface 4 3 1 Overview...

Страница 6: ...ion interface you may press to see all parameters 4 3 3 Alarm types Low alarm Red LED light LA on detection interface slow beeping vibration High alarm Red LED light HA on detection interface fast bee...

Страница 7: ...m records review deletion purpose press on detection interface then it will enter the function menu see below 4 4 Function menu 4 4 1 Overview 4 4 2 Press or to choose a specific function then press t...

Страница 8: ...ntact the seller to get the password first if it s needed When you see low battery alert or when the detector can t turn on because battery voltage is too low please charge the detector in time see be...

Страница 9: ...rential high concentration gas detector may not work normally 5 4 The detector will only detect gas concentration from the detection interface So for example when you are on the function menu it will...

Страница 10: ...es03 bosean com Possible fault Reasons Solution Unable to turn on the detector Battery voltage too low Charge in time Did not indicate 0 Sensor fluctuating Zero adjustment required Indication inaccura...