Simplified Load and Pitch Limit Charts
pro.Bose.com
Page 14 Installation and Safety Guidelines
Large Array Frame with Short Extender Bars (In Position): 6 Modules
6-Module (60° Total V)
6-Module (70° Total V)
6-Module (75° Total V)
Array
Desired
Pickup
Predicted
Array
Desired
Pickup
Predicted
Array
Desired
Pickup
Predicted
Modules
Pitch
Point
Pitch
Modules
Pitch
Point
Pitch
Modules
Pitch
Point
Pitch
RMxx05
10
17
10.3
RMxx05
10
17
10.7
RMxx05
10
20
10.4
RMxx05
5
23
5.0
RMxx05
5
23
5.5
RMxx10
5
26
5.0
RMxx10
0
28
0.6
RMxx10
0
29
0.1
RMxx10
0
31
0.5
RMxx10
-5
32
-2.9
RMxx10
-5
32
-2.6
RMxx10
-5
34
-4.9
RMxx10
-10
37
-9.9
RMxx20
-10
37
-9.6
RMxx20
-10
39
-9.4
RMxx20
-15
n/a*
n/a*
RMxx20
-15
n/a*
n/a*
RMxx20
-15
n/a*
n/a*
-20
n/a*
n/a*
-20
n/a*
n/a*
-20
n/a*
n/a*
-25
n/a*
n/a*
-25
n/a*
n/a*
-25
n/a*
n/a*
6-Module (80° Total V)
6-Module (85° Total V)
6-Module (90° Total V)
Array
Desired
Pickup
Predicted
Array
Desired
Pickup
Predicted
Array
Desired
Pickup
Predicted
Modules
Pitch
Point
Pitch
Modules
Pitch
Point
Pitch
Modules
Pitch
Point
Pitch
RMxx05
10
19
10.3
RMxx05
10
16
10.2
RMxx05
10
17
10.8
RMxx05
5
24
5.8
RMxx05
5
22
5.0
RMxx05
5
23
5.5
RMxx10
0
30
0.4
RMxx05
0
27
0.6
RMxx10
0
29
0.2
RMxx20
-5
32
-1.5
RMxx10
-5
32
-3.8
RMxx10
-5
32
-2.5
RMxx20
-10
38
-9.5
RMxx20
-10
36
-9.8
RMxx20
-10
37
-9.6
RMxx20
-15
n/a*
n/a*
RMxx40
-15
n/a*
n/a*
RMxx40
-15
n/a*
n/a*
-20
n/a*
n/a*
-20
n/a*
n/a*
-20
n/a*
n/a*
-25
n/a*
n/a*
-25
n/a*
n/a*
-25
n/a*
n/a*
Simplified Chart Notes:
1) Modeler
®
software calculates “array pitch” referenced to the acoustic centerline axis of the module in the first (top most) array
position. To convert the Modeler
®
array pitch number to the “array frame” pitch used in the above tables, take the Modeler
®
array
pitch number then add to this number one-half of the nominal coverage angle number of the module in the first array position.
See Figure 10.
2) n/a denotes that array frame pickup point is at maximum; additional pitch requires pull-back bracket with third attachment point.
3) n/a* denotes that WLL limits require use of pull-back bracket to reduce moment force loads; desired pitch may be possible using
additional pickup points of Extender Bars; please consult your local Bose Professional Systems Division Field Engineer or Technical
Support Specialist for additional information.
Figure 10. Modeler
®
Array Pitch versus Array Frame Pitch