81
TROUBLESHOOTING
This section provides troubleshooting guide-
lines to use for solving problems you may
encounter servicing the E4 Series II sys-
tems.
♦
E4 Series II hardware indicators
•
Normal operation
These are the indications of normal opera-
tion.
♦
System fault
A red SYSTEM STATUS LED indicates that
the system received an error from one of its
many internal components. A red SYSTEM
STATUS LED after AC power is switched on
may be caused by:
• A Power-On Self-Test failure
• A DSP error
• The DSP is offline
To determine the severity of the error, cycle
the unit’s power off and back on again. If the
SYSTEM STATUS indicator is now off, the
system has logged an error, but is still
operational.
When you check the error log using the
Installer™ software you can identify the
cause of the error, and determine an appro-
priate solution.
AMP OUTPUTS
1
2
3
4
SYSTEM
STATUS
AUDIO SOURCES
1
2
3
4
DIRECT
INPUT
STANDBY
STANDBY
Unlit
SYSTEM STATUS
Green
AMP OUTPUTS
Unlit or Green
AUDIO SOURCES
Unlit, Amber, or Green
DIRECT INPUT
Unlit
AMP OUTPUTS
1
2
3
4
SYSTEM
STATUS
AUDIO SOURCES
1
2
3
4
DIRECT
INPUT
STANDBY
System logged an error – Check the
Installer™ software Error Log.
SYSTEM STATUS
Indicator is red
Have you cycled
the E4 in and out
of STANDBY?
Switch the E4 unit to STANDBY and
then back to active again. If the
SYSTEM STATUS is green, the sys-
tem may have logged an error.
Check the Installer™ software Error
Log.
No
Yes
1. Switch the E4 unit to STANDBY.
2. Set the POWER switch to OFF.
3. Wait for STANDBY indicator to
turn off.
4. Set the POWER switch to ON.
5. Press the STANDBY switch.
1. Switch the E4 unit to STANDBY.
2. Set the POWER switch to OFF.
3. Disconnect all input/output sig-
nal cables.
4. Set the POWER switch to ON.
5. Press the STANDBY switch.
6. Reconnect one cable at a time
and check the Error Log.
Have you cycled
the E4 power
on and off?
Have you
disconnected all
input/output
cables?
Troubleshoot and
Repair Unit.
Yes
No
No
Yes
Содержание FreeSpace E4 Series II
Страница 99: ...99 Figure 6 DSP PCB Assembly Component Layout Figure 5 Flash Memory PCB Component Layout...
Страница 101: ...101 Figure 10 E4 Series II Upper and Lower Amplifier PCB Assembly Component Layout...
Страница 102: ...102 Figure 11 FS 4400 Upper Amplifier PCB Top Etch and Component Layout...
Страница 103: ...103 Figure 12 FS 4400 Upper Amplifier PCB Bottom Etch and Component Layout...
Страница 104: ...104 Figure 13 FS 4400 Lower Amplifier PCB Top Etch and Component Layout...
Страница 105: ...105 Figure 14 FS 4400 Lower Amplifier PCB Bottom Etch and Component Layout...