14
EP40-D Installation Guide
pro.Bose.com
What’s in the Box
The package contains one EP40-D device. An optional 24 V DC power
supply may be ordered separately.
Mounting
On flat mounting surface, mark screw locations through holes in the
mounting flange. Secured the unit to the mounting surface using
appropriately rated no. 6 screws through each mounting flange.
C
OnneCting
and
P
Owering
eP40-d
Audio Source Connections
Make the connections to the EP40-D before the power is applied.
The EP40-D inputs are balanced so check output type used by the
source to learn how to connect it correctly (see Hardware Connections
section). Attach audio sources to the inputs.
Powering Using PoE
Attach the “PoE + DATA” port to a spare PoE-enabled port on a
PoE switch using a CAT-5 cable. If a midspan injector is being used,
connect a spare input port to the Dante network switch using a
CAT-5 cable, and then connect the corresponding output port to
the “PoE + DATA” of the EP40-D.
Note:
Connecting a PoE switch directly to the “DATA” port on the
EP40-D will not power the unit.