7

Installation

Cabling

The CC-16 zone controller requires power and network cables. In some cases, these can be

supplied over the same multi-conductor cable.  When multiple CC-16s are used, run the

network (and optionally the power cable) from the ESP-88 to each zone controller in a daisy

chain. You can also run multiple home runs from the ESP-88 to each CC-16 in a star

configuration.

Note:

The ESP-88 does not supply power to the CC-16 zone controller.  A separate power

supply (not included) must be provided. Refer to Power Supply on page 12 for more informa-

tion about the required power supply.

The CC-16 can be wired using commonly available twisted-pair wire such as 24 AWG

unshielded CAT-5. Only one pair of wires is needed for the network connection. For a daisy

chain wired system, the maximum cable length is 2000 feet (610 meters). For a star topology,

the maximum length is 1000 feet (305 meters).

When supplying power over the same cable as the network pair, the limiting factor will be the

resistive loss in the wire. Smaller-gauge wire, will have higher resistance and cause a larger

voltage drop at the CC-16.  The CC-16 requires a minimum of 8VDC. 24 AWG wire has

resistance of about 27 ohms  per 1000 feet (305 meters), while 18 AWG wire has a resistance

of about 7 ohms per 1000 feet (305 meters).

The maximum distance can be calculated as follows:

d = ((V

SUPPLY

– 8V)/(Number of CC-16s * 100mA))/R

WIRE

)* 1000 feet)

For example, if V

SUPPLY

is 12V, the number of CC-16s = 2 and R

WIRE

= 27 (24 AWG), then:

d = ((12V – 8V)/(2 * 100mA))/27) * 1000 feet) = (4/.2/27 *1000 feet ) =750 feet (225 meters)

Содержание ControlSpace CC-16

Страница 1: ...ControlSpace CC 16 Zone Controller Safety Instructions Install Guide...

Страница 2: ...g is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been expos...

Страница 3: ...hich can be determined by turning the equipment off and on you are encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Inc...

Страница 4: ...zone controller is engineered to provide customized on site controls for ControlSpace sound systems Please read this guide to help you install and use your controller correctly Regulatory information...

Страница 5: ...RS 485 port Up to fifteen CC 16 units can be used per each ESP 88 to provide localized control of the system The maximum distance from ESP 88 to CC 16 is 2000 feet As a networked device remote reprogr...

Страница 6: ...t the ESP 88 connect the network wire to the RS 485 port and connect the power cable to a power source 5 Run the ControlSpace Designer software to configure and test The CC 16 must be connected to an...

Страница 7: ...AWG unshielded CAT 5 Only one pair of wires is needed for the network connection For a daisy chain wired system the maximum cable length is 2000 feet 610 meters For a star topology the maximum length...

Страница 8: ...TION Do not install the CC 16 in a box that has AC power mains CAUTION Do not place the power or network cables in the same conduit with the mains wire unless you are sure that special regulatory insu...

Страница 9: ...switch addresses Up to fifteen CC 16s can be connected to an ESP 88 and each must have a unique address Use the DIP switches numbered 4 5 6 and 7 on the back of the unit to set the address 1 through 1...

Страница 10: ...to terminate the network Termination is accomplished by setting DIP switches 1 and 2 to the ON position In most cases only one CC 16 zone controller the last unit in the daisy chain network furthest...

Страница 11: ...e which wire is connected to A and B 2 Connect the network cable to the CC 16 terminal blocks Ensure the wire connected to A on the ESP 88 is the same one connected to A on the controllers and that th...

Страница 12: ...e required cable AWG Use the ControlSpace accessory power supply or other suitable supply Individual country requirements are North America Power supplies used in North America must be NRTL listed and...

Страница 13: ...e the screws that are appropriate for your wall box the 6 for North American boxes and the M4 for Japanese European and Australian boxes CAUTION Do not overtighten the screws Overtightening may cause...

Страница 14: ...e Designer software Refer to the ControlSpace Designer Software user s guide for more information Check that the controls have been linked in the Designer software to signal processing blocks in the E...

Страница 15: ...15 Specifications Input voltage 8 18VDC 100mA Max network cable length 2000 feet 609m Number of CC 16 zone controllers per ESP 88 Sound Processor 15 Dimensions...

Страница 16: ...FITNESS FOR A PARTICULAR PURPOSE For how long In countries where the duration of the warranty is not determined by statute the Bose Limited Warranty lasts five years from the purchase date For countr...

Страница 17: ...T TO SPECIFIED CONDITIONS YOU MAY ALSO HAVE OTHER LEGAL RIGHTS WHICH APPLY TO THE PRODUCT YOU HAVE ACQUIRED THESE LEGAL RIGHTS VARY FROM STATE TO STATE OR COUNTRY TO COUNTRY SOME PLACES DO NOT ALLOW T...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20 2007 Bose Corporation The Mountain Framingham MA 01701 9168 USA 285042 AM Rev 01...

Отзывы: