SAFETY INFORMATION

1.

Parts that have special safety characteristics are identified by the          symbol on schematics

or by special notes on the parts list. Use only replacement parts that have critical characteristics
recommended by the manufacturer.

2.

 Make leakage current or resistance measurements to determine that exposed parts are

acceptably insulated from the supply circuit before returning the unit to the customer.
Use the following checks to perform these measurements:

A. Leakage Current Hot Check

-With the unit completely reassembled, plug the AC line cord

directly into a 120V AC outlet. (Do not use an isolation transformer during this test.) Use a leak-

age current tester or a metering system that complies with American National Standards Institute

(ANSI) C101.1 “Leakage Current for Appliances” and Underwriters Laboratories (UL) UL6500 /

UL60065 / IEC 60065 paragraph 9.1.1. With the unit powered on, measure from a known earth

ground (metal water pipe, conduit, etc.) to all exposed metal parts of the unit (antennas, handle

bracket, metal cabinet, screw heads, metallic overlays, control shafts, etc.), especially any

exposed metal parts that offer an electrical return path to the chassis. Any cur-rent measured

must not exceed 0.5 milliamp. Reverse the unit power cord plug in the outlet and repeat test.

ANY MEASUREMENTS NOT WITHIN THE LIMITS SPECIFIED HEREIN INDICATE A POTEN-

TIAL SHOCK HAZARD THAT MUST BE ELIMINATED BEFORE RETURNING THE UNIT TO THE

CUSTOMER.

B. Insulation Resistance Test Cold Check

-(1) Unplug the power supply and connect a jumper

wire between the two prongs of the plug. (2) Turn on the power switch of the unit. (3) Measure
the resistance with an ohmmeter between the jumpered AC plug and each exposed metallic
cabinet part on the unit. When testing 3 wire products, the resistance measured to the product
enclosure should be between 2 and infinite MOhms. Also, the resistance measured to exposed
input/output connectors should be between 4 and infinite MOhms. When testing 2 wire products,
the resistance measured to exposed input/output connectors should be between 4 and infinite
MOhms. If it is not within the limits specified, there is the possibility of a shock hazard, and the
unit must be repaired and rechecked before it is returned to the customer.

PART LIST NOTES

1.

 This part is not normally available from Customer Service. Approval from the Field Service

    Manager is required before ordering.

2.

 The individual parts located on the PCBs are listed in the Electrical Part List.

3.

           This part is critical for safety purposes. Failure to use a substitute replacement with the

    same safety characteristics as the recommended replacement part might create shock, fire
    and/or other hazards.

4.

This part is referenced for informational purposes only. It is not stocked as a repair part. Refer

    to the next higher assembly for a replacement part.

Содержание Computer MusicMonitor

Страница 1: ... 2007 Bose Corporation Reference Number 301248 SM Rev 03 Service Manual Bose Computer MusicMonitor Electronic Copy Only ...

Страница 2: ...ncin erate Dispose of used batteries promptly Replace only with a battery of the correct type and model number Danger of explosion if remote battery is incorrectly replaced Replace with only Duracell Eveready Energizer Maxell Toshiba or Shun Wo CR2032 or DL2032 3 volt lithium battery CAUTION The Bose Computer MusicMonitor contains no user serviceable parts To prevent warranty infractions refer ser...

Страница 3: ...HIN THE LIMITS SPECIFIED HEREIN INDICATEAPOTEN TIAL SHOCK HAZARD THAT MUST BE ELIMINATED BEFORE RETURNING THE UNIT TO THE CUSTOMER B Insulation Resistance Test Cold Check 1 Unplug the power supply and connect a jumper wire between the two prongs of the plug 2 Turn on the power switch of the unit 3 Measure the resistance with an ohmmeter between the jumpered AC plug and each exposed metallic cabine...

Страница 4: ...are available for replacement See page 4 for part numbers Repairability The Speaker System demo mode enables sales channels to build a highly effective display in low sales touch environments with a variable source input In demo mode The Speaker System turns on automati cally when power is applied When the Speaker System turns on in demo mode the volume is automatically set to maximum Entering Dem...

Страница 5: ... 240VAC Input Frequency Range 50 60 Hz 1 0 Amp rms Maximum for 120VAC AC Input Current 0 5 Amp rms Maximum for 230VAC 30 Amp Maximum at 120VAC Maximum In Rush Current 60 Amp Maximum at 240VAC Speaker Inputs Input Power 17V DC 2A Input Signal 2 0 Vrms Maximum Frequency Response 63Hz to 15KHz Maximum SPL 90dB Watts Per Channel 18 Watts Driver Complement One magnetically shielded 1 96 50 mm full rang...

Страница 6: ...240V AU LINE CORD 230V SP LINE CORD 220V KOREA 304186 001 304186 002 304186 004 304186 003 304186 005 304186 006 304186 007 3 6 POWER SUPPLY UNIVERSAL 16V 2A 302251 001 3 7 DEMO DISC 307153 001 8 CABLE INPUT COMPUTER MUSIC MONITOR 304187 001 9 REMOTE CONTROL 307631 004 10 GUIDE OWNERS M3 3 LANG US GUIDE OWNERS M3 6 LANG EU GUIDE OWNERS M3 6 LANG AP 307625 307626 307627 11 CARTON DC 9 13 X 7 06X 2 ...

Страница 7: ... Both left and right speakers are available for replacement See page 4 for part numbers 1 Air Leak Test The air leak test is performed just below the loudspeaker s tuned frequency At this frequency the passive radiators exhibit high excursion Therefore it is normal to hear suspension noise from the passive radiators 1 1 Apply a 300 mVrms 60 Hz signal to the input 1 2 Set the volume to the maximum ...

Страница 8: ...D demo disc 5 12 18 07 02 Deleted audio cable part number Added the Companion 3 audio cable in it s place The Computer MusicMonitor audio cable is unreliable The Companion 3 audio cables should used until the quality of the correct cable is available 5 01 09 08 03 Removed Companion 3 audio cable Replaced it with the MusicMonitor audio cable Carton part number changed from 306751 to317310 All Music...

Страница 9: ...SPECIFICATIONS AND FEATURES SUBJECT TO CHANGE WITHOUT NOTICE Bose Corporation The Mountain Framingham Massachusetts USA 01701 P N 301248 SM Rev 03 8 2007 H http serviceops bose com ...