![Bose ACOUSTIMASS PRO Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/bose/acoustimass-pro/acoustimass-pro_manual_2792388008.webp)
8
Use for serial numbers 050121 and above
(later EQ)
Use for serial numbers 050120 below
(earlier EQ)
7. Amplifier Distortion
7.1 Apply a 50Hz, 1kHz and 10kHz signal
to the input of the amplifier at a level to
obtain an output according to the following
table. The distortion measured at the output
should be less than 0.4% at 50Hz and
1kHz and less than 1.0% at 10kHz.
TEST PROCEDURES
8. Hum
8.1 Short all inputs to input ground. The
hum measured at the output should be less
than 4mVrms, "C" weighted.
9. Noise
9.1 Short all inputs to input ground. The
noise measured at the output should be
less than 3mVrms, "A" weighted.
10. Common Mode Rejection Ratio
(CMRR)
10.1 Connect the positive side of a signal
generator to the positive and negative side
of the XLR amplifier input. Apply a 3.0Vrms
60Hz and then a 1kHz signal. Reference a
dB meter to the applied signal.
10.2 The output should be less than
-40dB.
Frequency
Output
Tolerence
30Hz
0.2dB
±
2.5dB
50Hz
17.1dB
±
1.5dB
90Hz
12.6dB
±
1.5dB
150Hz
11.2dB
±
1.5dB
350Hz
4.9dB
±
1.5dB
1kHz
Reference
-
4kHz
14.7dB
±
2.7dB
7kHz
13.0dB
±
2.7dB
13kHz
22.0dB
±
5.0dB
20kHz
14.8dB
±
3.0dB
Frequency
Output
Tolerence
30Hz
-4.6dB
±
4.0dB
50Hz
13.5dB
±
1.8dB
90Hz
10.0dB
±
1.8dB
150Hz
11.2dB
±
1.8dB
350Hz
4.7dB
±
2.0dB
1kHz
Reference
-
4kHz
14.8db
±
3.0dB
7kHz
14.7dB
±
3.0dB
13kHz
25.4dB
±
5.5dB
20kHz
16.5dB
±
4.0dB
Variation
Output
Power
Reference
Voltage
Load
100V
300W
70Vrms
16
Ω
120V
450W
85Vrms
16
Ω
240V
450W
85Vrms
16
Ω