background image

1.0

Specifications

Input Power:

  9 to 15 VDC, 6 mA nominal (35 mA with LED on).

Standby Power:

  There is no internal standby battery. Connect to standby power as a backup in the event primary power

fails. Six mA-H required for each hour of standby time needed. Four hours minimum is required for UL Listed Requirements.

Temperature:

  The operating temperature range is -20° to +120°F (-29° to +49°C). For UL Listed Requirements, the

temperature range is +32° to +120°F (0° to +49°C).

Microwave Frequency:

  10.525 Ghz, ±25.000 Mhz.

Coverage

:  35 ft. by 35 ft. (10.7 m by 10.7 m)

Internal Pointability

:  +2° to –10° Vertical, ±10° Horizontal.

Tamper

:  Tamper condition transmitted through the Zonex bus when the cover is removed.

Requirements:

 Requires a compatible control panel with a POPEX module installed.

Options

:  B328 Gimbal Mount Bracket, B335 Low Profile Swivel Mount Bracket (use of a bracket may reduce range and

dead zone areas).

U. S. Patent Numbers

:  #4,660,024; #4,764,755; #5,077,548; #5,208,567; #5,262,783; #5,450,062. Other patents pending.

2.0

Installation Considerations

• Never install the detector in an environment that causes an alarm condition in one technology. Good installations start with

the LED 

OFF

 when there is no target motion. It should never be left to operate with the tri-color LED in a constant or

intermittent green, yellow, or red condition.

• Point the unit away from outside traffic (roads/alleys). 

Remember:

 Microwave energy will pass through glass and most

common non-metallic construction walls. Avoid installations where rotating machines (e.g., ceiling fans) are normally in
operation within the coverage pattern.

• Point the unit away from glass exposed to the outdoors and objects that may change temperature rapidly. 

Remember:

  The PIR

detector will react to objects rapidly changing temperature within its field-of-view.

• Eliminate interference from nearby outside sources.

3.0

Mounting

1.

Select a location likely to intercept an intruder moving 

across

 the

coverage pattern. The surface should be solid and vibration free.
Mounting height range is 6 to 8 ft. (1.8 to 2.4 m). 

Recommended

mounting height is 6.5 ft. (2 m).

2.

Remove the cover. Insert a flathead screwdriver into the locking tab
hole at the bottom front of the detector. Pull the cover up and forward.

3.

Mount the unit with the terminal block up.

4.

Remove the circuit board from the base. Loosen the Vertical Adjust
Screw and slide the circuit board down then out.

5.

Break away the appropriate thin-wall wire entrance and mounting
hole coverings in the base.

6.

Using the base as a template, mark the location of the holes on the
mounting surface.

7.

Route wiring (unpowered) as necessary. Route to the rear of the base and through the wire entrance.

8.

Firmly mount the base to the mounting surface. Return the circuit board to the base and tighten the Vertical Adjust Screw.

Microwave PIR Detector with POPIT Interface ZX835

Installation Instructions

Содержание ZX835

Страница 1: ...from outside traffic roads alleys Remember Microwave energy will pass through glass and most common non metallic construction walls Avoid installations where rotating machines e g ceiling fans are normally in operation within the coverage pattern Point the unit away from glass exposed to the outdoors and objects that may change temperature rapidly Remember The PIR detector will react to objects ra...

Страница 2: ...operation of the tri color LED If the tri color LED indication is not desired after setup and walk tests are completed place the plug in the OFF position The OFF position does not prevent the tri color LED from indicating a supervision trouble condition PIR Sensitivity Selection Pins The PIR response sensitivity may be selected by placing the plug across the pins marked STD for Standard or INT for...

Страница 3: ...he board up will angle the pattern downward Tighten the screw snug when positioning is completed Note The pattern may be moved 10 horizontally by moving the lens window left right 8 2 Establishing Microwave Coverage Note It is important to wait one minute after removing replacing the cover so the microwave portion of the detector can settle and to wait at least 10 seconds between the following wal...

Страница 4: ...n lens is not recommended for installations containing pets or small animals The Look Down finger is shown in black below 12 0 Special Instructions for Installations Containing Pets The ZX835 will provide reasonable protection from nuisance alarms caused by the following sources A dog up to 100 pounds 45 kg Up to 10 cats Two 60 pound 27 kg dogs Random flying birds Multiple small rodents such as ra...

Отзывы: