Cleaning and servicing
en
39
3.
Reinsert the siphon cap into the
auxiliary compartment (making
sure to align the installation marks)
and push down firmly until it clicks
into place.
4.
Place the auxiliary compartment
back into the detergent drawer.
Note:
Clean the auxiliary liquid deter-
gent dispenser compartment regu-
larly to avoid residue and blockages.
17.4 Cleaning the drain pump
Clean the drain pump in the event of
faults, e.g. blockages or rattling
noises.
Emptying the drain pump
1.
Turn off the water tap.
2.
Switch off the appliance.
3.
Disconnect the appliance's mains
plug from the power supply.
4.
Open and remove the service flap.
1
1
2
5.
Slide a sufficiently large container
under the opening.
6.
Take the drain hose out of the
holder.
Содержание XQG100-WGC354B01W