2.

Preconditions for installation

The appliance can only be sold in the countries mentioned
in the type plate.

2.1

Regulations

Gas safety (installation & use) Regulations 1998.
It is the law in GB that a competent Person in accordance
with the above regulations installs all gas appliances.
Failure to install appliances correctly could lead to
prosecution.
It is in your interest , and that of safety, to ensure compliance
with the law.

Caravan & holiday homes:

the installation must meet the following standards Bs 5482:2
LPG and EN721 ventilation.

2.2

Location

The appliance should be sited in a well ventilated room where
it will not be exposed to temperatures below freezing.
To prevent corrosion, the combustion air must not contain
any corrosive substances. Substances classed as corrosion-
promoting include halogenated hydrocarbons such as are
found in solvents, paints, adhesives, aerosol propellants and
various household cleaners. Appropriate measures should
be taken where necessary.
With the exception of the flue pipe, the surface temperature
of the appliance is below 85 °C. No special safety measures
are therefore necessary.
Site appliance as shown in Fig. 5.
Always site appliance in a location not exposed to
temperatures below freezing. If this is not possible, the
appliance must be switched off and drained and the batteries
removed whenever there is a risk of freezing.
Do not install the appliance in rooms where the free volume
is less than 8 m

3

.

Air admission

The room where the appliance is to be installed should be
provided of fresh air inlet areas according with the below
table.

Minimum requirements are listed above. Local regulations
should allways be observed.

2.3

Fixing the appliance

Remove the temperature control and the output control.
Remove the outer case by sliding it forwards and then lifting
upwards.
Fix the appliance using the sleeves and hooks supplied so
that it is vertical.

Never allow the appliance to rest against water or gas
pipes.

2.4

Water connection

It is advisable to drain the appliance before installing it as
any dirt or grit inside it could reduce the water flow rate and,

To prevent problems caused by sudden pressure fluctuations
in the water supply, it is advisable to fit a non-return valve
to the water outlet.

2.5

Gas connection

Take care to ensure dirt is not allowed to enter gas inlet.
Make sure that the type of gas specified on the appliance
type plate is the same as that supplied by the gas authorities.
Select pipe diameter to suit output of instantaneous water
heater being installed.
Fit gas service cock as close to appliance as possible.

Fig. 4

Water connection

in extreme cases, could completely clog up the appliance.
Mark hot water (fig.4, pos.B) and cold water pipes (fig.4,
pos.A) so as to prevent confusion.
Connect pipe to automatic water valve using the connecting
kit supplied.

Appliance

Minimum area

WR 8

WR 11

 60 cm

2

Содержание WR11 series

Страница 1: ...use or store easily combustible materials in the vicinity of the appliance Gas Instantaneous Water Heater Installation Manual and Operating Instructions Installation and servicing of the appliance may only be carried out by an approved technician The appliance should be regularly serviced in order to ensure that it remains in perfect and safe working order If there is a risk of freezing the applia...

Страница 2: ...no tin lead lining Automatic water valve made of glass fibre reinforced polyamide 100 recyclable Automatic control of water flow maintains constant flow rate even with fluctuating supply pressure Proportional adjustment of gas and water flow rates in order to ensure an even temperature gradient Gas valve with adjustable output via a slide control 1 3 Explanation of Model Code Contents W Gas instan...

Страница 3: ...put control 21 Igniter button 22 Main gas valve 23 Gas valve for pilot burner 24 Pilot burner injector 25 Gas valve 26a Testing point for supply pressure 26b Testing point for burner pressure 27 Thermocouple 28 Igniter electrode 29 Temperature limiter 30 Flue gas safety device 1 Front cover 2 Hole for fixing to wall 3 Observation window 4 Temperature control 5 Output control 6 Gas connection 7 Exh...

Страница 4: ...in heat input Qmin kW 8 1 8 1 Supply pressure LPG butane propane G30 G31 mbar 28 30 37 28 30 37 Consumption LPG butane propane G30 G31 kg h 1 1 6 Number of injectors 12 12 Max water pressure pw bar 12 12 Temperature control at maximum setting Temperature increase C 50 50 Flow rate l min 3 5 5 5 Min operating pressure pwmin bar 0 1 0 1 Temperature control at minimum setting Temperature increase C 2...

Страница 5: ...moved whenever there is a risk of freezing Do not install the appliance in rooms where the free volume is less than 8 m3 Air admission The room where the appliance is to be installed should be provided of fresh air inlet areas according with the below table Minimum requirements are listed above Local regulations should allways be observed 2 3 Fixing the appliance Remove the temperature control and...

Страница 6: ...ess steel or fibre concrete Fit as shown in Fig 5 A flexible or rigid pipe should be used fit it inside the flue socket The external diameter of the pipe should be slightly smaller than the dimension specified in the appliances dimensions table Fig 5 Minimum distances cm 2 7 Commissioning Turn on the gas and water cocks and check all connections for leaks Check flue gas safety device good function...

Страница 7: ...ing In first place it must dislocate the output control of the off position to the ignition position see fig 7 Press in the slide control knob and subsequently press the piezo button Release the slide control after about 15 seconds if the pilot flame does not stay alight repeat the operation Ignition may not be successful due to the presence of air inside the gas supply pipe especially if first co...

Страница 8: ...chnician Problem Cause Solution Pilot flame stay alight Blocked pilot burner Clean Several atempts required to turn pilot flame on Yellow pilot flame Flame goes out while appliance is in operation Flue gas safety device has tripped Ventilate room Wait 10 minutes then restart appliance If problem recurs call an approved technician Temperature limiter has tripped Wait 10 minutes then restart applian...

Страница 9: ...9 6 720 607 884 ...

Страница 10: ...10 6 720 607 884 ...

Страница 11: ...11 6 720 607 884 ...

Страница 12: ...urning control clockwise reduces water flow rate and increases water temperature Temperature adjustment Depress slide control knob and hold it in Ignition output decrease output increase Press the piezo igniter Repeat these steps if the flame does not stay alight Switching off Move slide control to the far left Release the slide control knob after approximately 10 seconds ...