Bosch WR10**B SERIES Скачать руководство пользователя страница 7

7

6 720 607 823

3.8

Troubleshooting

Installation, servicing and repairs may only be carried out by an approved engineer.
The following table illustrates only a few solutions to straightforward problems.

The operations marked with “*” may only be carried out by an approved technician

Fault

Possible Cause

Solution

Appliance does not ignite.

Batteries flat, incorrectly fitted or switch set to
Off

Check position and refit/replace.

Pilot flame lights slowly/with difficulty

Batteries flat.

Replace.

Red LED flashes

Water not hot enough

Check position of water temperature control and
adjust to obtain desired hot water temperature

Water not hot enough, no flame

Gas supply dynamic pressure too low

Check gas cylinder governor and replace if
incompatible or damaged
Check whether gas cylinder (butane) is freezing
when appliance is in operation and re-site in
warmer location if necessary

Flame goes out while appliance is in
operation

Temperature limiter has tripped

Wait 10 minutes then restart appliance. If
problem recurs, call an approved technician.

Flue gas safety device has tripped

Ventilate room. Wait 10 minutes then restart
appliance. If problem recurs, call an approved
technician.

Reduced water flow rate

Inadequate inlet flow rate

Check and adjust.

Dirt in water service cock or mixer unit

Check and clean.

Automatic water valve clogged

Clean filter.*

Heat exchanger clogged (scale)

Clean and descale as necessary.*

Function check

*

Flue gas safety device function check:
- Disconnect flue pipe
- Replace with pipe (about 50 cm long) with sealed end
- Fit pipe vertically
- Start up appliance at rated output and set temperature

control to maximum temperature.

Under those conditions, the appliance should shut down
after two minutes. Remove temporary pipe and reconnect
flue pipe.
* This work may only be carried out by an approved engineer.

3.7

Converting to a different gas type

Use only the 

genuine Bosch conversion kit

. Conversion

may only be carried out by an approved technician.

Содержание WR10**B SERIES

Страница 1: ...installer Do not use or store easily combustible materials in the vicinity of the appliance Gas Instantaneous Water Heater Installation and Operating Instructions Installation and servicing of the appliance may only be carried out by an approved technician The appliance should be regularly serviced in order to ensure that it remains in perfect and safe working order If there is a risk of freezing ...

Страница 2: ...y during the time between opening of the water valve and activation of the main burner Heat exchanger has no tin lead lining Automatic water valve made of glass fibre reinforced polyamide 100 recyclable Automatic control of water flow maintains constant flow rate even with fluctuating supply pressure Proportional adjustment of gas and water flow rates in order to ensure an even temperature gradien...

Страница 3: ...23 Igniter unit 24 LED indicator for burner status 25 On Off switch 26 LED indicator for battery charge level 27 Servo valve 28 Output control 29 Gas valve 30 Gas valve for pilot burner 31 Pilot burner injector 32 Pilot burner pipe 33 Temperature limiter 34 Flue gas safety device 1 Front cover 2 Hole for fixing to wall 3 Observation window 4 Temperature control 5 LED indicator for battery charge l...

Страница 4: ... heat output Pn kW 17 4 19 2 Rated min heat output Pmin kW 7 0 7 0 Output modulation range kW 7 0 17 4 7 0 19 2 Rated max heat input Qn kW 20 0 21 8 Rated min heat input Qmin kW 8 1 8 1 Supply pressure Natural gas G20 25 mbar 20 25 LPG butane propane G30 G31 mbar 28 30 37 Consumption Natural gas G20 25 m 3 h 2 3 LPG butane propane G30 G31 kg h 1 7 Number of injectors 12 12 Max water pressure pw ba...

Страница 5: ...low table Minimum requirements are listed above Local regulations should allways be observed 2 3 Fixing the appliance Remove the temperature control and the output control Remove the outer case by sliding it forwards and then lifting upwards Fix the appliance using the sleeves and hooks supplied so that it is vertical Never allow the appliance to rest against water or gas pipes 2 4 Water connectio...

Страница 6: ...unction This water heater is fitted with automatic electronic ignition that provides for easy commissioning All that is required is to press the On Off switch Fig 8 The appliance will then ignite automatically as soon as a hot water tap is turned on The pilot flame ignites first and then about four seconds later the main burner the pilot flame subsequently goes out after about 20 seconds Consequen...

Страница 7: ...lame goes out while appliance is in operation Temperature limiter has tripped Wait 10 minutes then restart appliance If problem recurs call an approved technician Flue gas safety device has tripped Ventilate room Wait 10 minutes then restart appliance If problem recurs call an approved technician Reduced water flow rate Inadequate inlet flow rate Check and adjust Dirt in water service cock or mixe...

Страница 8: ...in burner on On I Off 0 Turning control anti clockwise increases water flow rate and reduces water temperature Turning control clockwise reduces water flow rate and increases water temperature Temperature adjustment Output control Low water temperature Lower output High water temperature Higher output Safety precautions for use of batteries Do not dispose of batteries with normal household waste t...

Отзывы: