Commissioning
Check and, if necessary, adjust
Start configuration wizard
and the most important
settings for the heating system configuration.
Central
heating
settings
1)
1) Limited use depending on the heat source used.
System data
The settings that apply to the entire heating system, e.g. minimum outside
temperature and building type. Additional settings for heating circuit 1 and DHW
system are available in this menu (if directly installed in the heat source).
Boiler data
2)
2) Not available if cascade module (e.g. MC 400) is installed.
Product-specific settings for the installed heat source, e.g. pump characteristic map
or pump over-run time.
Heating circuit
1
–
4
Heating circuit-specific settings of the installed heating circuits 1 to 4, e.g. frost
protection and heating curve.
Screed drying
Configurable program for screed drying with underfloor heating system.
DHW
settings
DHW system
I
or
II
Separate settings options for two DHW systems, e.g. maximum DHW temperature,
time for the thermal disinfection and configuration of the DHW circulation and charge
(loading) pumps.
Solar settings
If a solar system is installed: see technical documentation for solar modules.
Hybrid settings
If a hybrid module is installed: see technical documentation for hybrid system.
Cascade settings
If a cascade module is installed for the control of several heat sources: see technical
documentation for cascade module (MC 400).
Diagnosis
System diagnosis:
•
Perform function test of individual components (e.g. pumps and valves).
•
Compare set and actual values.
•
Call up current faults and the fault history.
•
Call up the software versions of all BUS devices.
Additional functions:
•
Define maintenance intervals.
•
Enter installer contact details.
•
Reset different settings.
•
Calibrate room temperature sensor and clock.
Table 12 Overview of the service menu