12
Installation
Sense II – 6 720 818 367 (2015/10)
Fig. 11
Mount installation frame to the back of the controller
▶ Observe the installation instructions of the relevant heat
source.
3.7
Installing the connector with link
The advanced weather compensated controller only works
properly, when the connector with link (
is installed correctly in the heat source.
The plug with jumper must be installed in all heat sources with
HT4i electronics (e.g. Greenstar Compact) (
▶ Observe the installation instructions of the relevant heat
source.
Fig. 12
Low voltage connectors of a heat source
6 720 812 774-12.1O
Low voltage room thermostat input (NOT USED)
EMS/EMS 2 BUS connection
External cut off switch (NOT USED) – plug in
connector with link (
Outdoor temperature sensor
Cylinder sensor (NOT USED on Combi boilers)
Low loss header sensor (NOT USED)
Table 5 Low Voltage terminal strip
Failure to install the connector with link into
the required heat source will stop the CH from
coming on.
6 720 812 774-16.1O
EMS
EMS
EMS
EMS