UK/IE

Installation and operating instructions

Radio Frequency Twin Channel Programmable Room Thermostat and Receiver

Greenstar Comfort II RF

select

advance

select

advance

menu

6720810965-00.1Wo

For EMS compatible Worcester Greenstar condensing boilers

672081

0965 (2017/02)

Содержание Worcester Greenstar Comfort II RF

Страница 1: ...nstructions Radio Frequency Twin Channel Programmable Room Thermostat and Receiver Greenstar Comfort II RF select advance select advance menu 6720810965 00 1Wo For EMS compatible Worcester Greenstar condensing boilers 6720810965 2017 02 ...

Страница 2: ...10 5 1 1 Heating 10 5 1 2 HW Hot water 11 5 1 3 Holiday function 11 5 1 4 Info 12 5 1 5 Setting 12 5 2 Installer 13 5 2 1 System data 14 5 2 2 Reset all 14 5 2 3 Heat circuit 14 5 2 4 Maintenance 14 5 2 5 System info 15 5 2 6 Radio settings Pair Unpair 15 5 3 Key lock 15 6 Receiver 15 6 1 Override push button 15 6 2 Pairing Unpairing 15 7 Fault finding and resolution 16 7 1 Fault table 16 7 2 Unit...

Страница 3: ...nderstand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision BS EN 60335 1 2012 Installation commissioning and servicing Installation commissioning and servicing must only be carried out by a competent engineer Only use original spares Electrical work Electrical work must only be carried out by a qualified...

Страница 4: ...onveniently done from the Programmable room thermostat making the Comfort II RF an excellent solution if your boiler is not easily accessible The unit has user and installer menus to allow the setting of the temperatures time programs monitoring of system information setting current time date daylight savings maintenance schedules and pairing the device with the Receiver Fig 1 Programmable room th...

Страница 5: ...nts into the boiler fascia or with an optional wall mounting kit onto the wall and the Programmable room thermostat which mounts on a wall in a suitable reference room 3 1 Receiver mounting There are two methods of mounting the Receiver In the boiler fascia On the wall optional wall mounting kit 7 733 600 039 If your boiler is mounted remotely i e in the loft or an outbuilding you may want the Rec...

Страница 6: ... Receiver down into the body of the wall plate to secure Engagethetabsonthetopretainer 3 intotheslotsonthe wall plate 1 and push down onto the Receiver to secure Fig 4 Fitting the Receiver to wall plate assembly 3 2 Programmable room thermostat mounting Fitting the batteries Insert the batteries ensuring that the positive end of the batteryisinsertedintothepositive terminaloftheholder Fig 5 Fittin...

Страница 7: ...is flexible for positioning there is no requirement to hard wire the device Thethermostatrequiresfreeairflowandshouldbemountedin an open area and not obscured by curtains or furniture The thermostatshouldbemounted nocloserthan300mmtometal objects including metal wall boxes Mount the thermostat on a wall that is not subject to direct sunlight or draughts preferably on an inside wall at1 2 metres ab...

Страница 8: ...eating In the Auto mode press the Advance button once to move to the next on or off time press for a second time to return to the current programme the operational modes for the hot water are either ON OFF ONCE AUTO or ADV press the HW select button to choose either ON hot water is permanently on OFF hot water is permanently off ONCE hot water is on from the first programmed on time to the last pr...

Страница 9: ...nob once and releasing will display Permanently and the temperature that is permanently set Fig 11 Permanently ON 4 2 3 Room temperature indication in the Off mode When the Programmable room thermostat is in the Off mode pressing the knob once and releasing will display Permanently and the temperature of 5 C After three seconds the display will revert back to show the actual room temperature and a...

Страница 10: ...nutes Press the knob to confirm Temp setting1flashes thiswillbethetemperaturethatis comfortable for your home during the first time period Turn the knob to set the required temperature and press the knob to confirm Time setting 2 hours flash this will be the time that you want the temperature set lower maybe while the house is unoccupied Turn the knob to select the hours setting and press the knob...

Страница 11: ...ours flash Turn the knob to select the desired hours setting Press the knob to confirm The minutes flash Turn the knob to select the desired minutes Press the knob to confirm The first DHW OFF hours flash Turn the knob to select the desired hours setting Press the knob to confirm The minutes flash Turn the knob to select the desired minutes Press the knob to confirm Now the second DHW ON hours fla...

Страница 12: ...ction allows the current time and date to be set this would be used on initial set up of the Programmer or if the time and date were lost due to the boiler being switched off for an extended period of time Turn the knob to select Time date and press to enter the function Press the knob to select clock time Press the knob and the hours flash Turn the knob to select the correct hour Press the knob t...

Страница 13: ...Reset all this function will reset all the Programmable Room thermostat user settings back to the factory default settings Any customised ON OFF times and temperatures for heating orON OFFtimesforhotwateroranyothercustomisedsettings will have to be re entered Any default settings are described at the beginning of the functional descriptions Turn the knob to select Reset all Press the knob and NO f...

Страница 14: ...o back to Heat circuit 5 2 4 Maintenance 1 Fault history Boiler faults Cont faults 2 Landlord func Maint date Maint contact a Fault history Press the knob and Boiler faults is displayed Boiler faults are displayed here and at the boiler the Programmable Room thermostat may be located remotely from the boiler so viewing the boiler faults at the Programmable Room thermostat may be useful Press the k...

Страница 15: ...ing a local error not a boiler fault During this time the override push button can be briefly pressed once less than 3 seconds to override the Programmable room thermostat and maintain the boiler function for heating and hot water During override the LED will be on but will flash off briefly to indicate an override situation Press the override push button again briefly to cancel the override featu...

Страница 16: ...raught or energy loss Move the Room thermostat to a more suitable location refer to section 3 2 No flame symbol visible on the Room thermostat The actual temperature is close to the target temperature The control turns the boiler off early to prevent overshoot Set the target temperature is at least 2 ºC above the current displayed temperature It takes up to 6 minutes for the flame to come on The f...

Страница 17: ...main screen The action takes approximately one minute A25 Multiple pairing fault Displayed when no zone is available for this room thermostat Unpair units and pair back up using a different zone setting for each room thermostat Up to 3 zones can be set up A26 Multiple pairing fault Displayed when 2 or more Programmable room thermostats are paired to the same Receiver each with the same zone settin...

Страница 18: ... replacing within 60 days or the programmed settings will be lost Replace the batteries with the same type LR6 AA 1 5V alkaline Fig 17 Low battery indication Battery access To remove the room thermostat from the wall mounting plate 1 Insert a suitable flat bladed screwdriver into the slot on the bottom edge of the device 2 Twist the screwdriver gently until the bottom catches are released 3 Separa...

Страница 19: ...cycled Electrical and electronic equipment Scrap electrical and electronic equipment must be collected separately and returned to an environmentally compatible recycling facility European Directive on waste electrical and electronic equipment Use the country specific return and collection system for the disposal of electrical and electronic equipment Battery recycling Batteries rechargeable or not...

Страница 20: ...0 123 9779 LITERATURE 0330 123 9119 TRAINING 0330 123 0166 SALES 0330 123 9669 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 0330 123 9559 Worcester Bosch Group is a brand name of Bosch Thermotechnology Ltd worcester bosch co uk Comfort II 6 720 810965 2017 02 2703726_REV1 ...