PRE-INSTALLATION
6 720 821 670 (2018/06)
21
4.5.6
ROOMS CONTAINING A BATH OR SHOWER
• The installation
must be in accordance with the latest edition of
the IET Wiring Regulations BS7671
.
• Circuit breaking devices should be used in accordance with the
regulations.
• The diagram is for guidance only.
The appliance must only be installed outside zone 2.
Fig. 18 Bathroom installations
[1]
Zone 1
[2]
Zone 2
[2*]
Without the end wall, zone 2 must extend 600mm from the bath
[A]
600mm radius from bath or shower
NOTICE:
Any switch or appliance control using mains
electricity must not be within reach of a person using the
bath or shower.
6720646608-124.6Wo
2*
1
2
1
2
2
1
600mm
600mm
600mm
2250mm
2250mm
2*
A
A
A