Installation
Greenstar 8000 Style – 6720883855 (2019/01)
36
5.5
Electrical connection
DANGER:
Risk of electric shock!
▶ Isolate electrical components from the power supply (230 V AC)
(fuse, circuit breaker) and secure against unintentional re-
connection before carrying out any work.
Information on safe isolation can be found in the Health and Safety
Executive guidance HSG85.
▶ Check for zero potential before proceeding with work, using test
equipment approved to GS38 to confirm that the electricity supply is
disconnected.
Electrical considerations:
▶ All electrical work must be carried out by a competent and authorised
person.
▶ All work must comply with the current IET Wiring Regulations.
▶ The isolator shall be situated next to the appliance for new systems
and, where practicable, replacement appliances.
▶ The mains electrical supply to the appliance must be through either,
a fused double pole isolator or a fused three pin plug and unswitched
socket.
▶ The isolator must have contact separation of 3mm minimum between
poles. Any system connected to the appliance must not have a
separate electrical supply.
▶ Any additional components that are connected to the appliance that
require 230 Volts must be connected to the same supply as the
appliance.
▶ Type A RCDs
must be employed where additional protection is
required.
▶ External fuse 3 Amps.
▶ When stripping the wires, ensure copper strands do not fall into the
control box.
NOTICE:
Risk of damage from hot appliance components.
Hot appliance components can damage electrical cables.
▶ Ensure all electrical cables are in the correct cable guides and away
from hot appliance components.
Cable routing
▶ Route cables through support guides and retaining clips.
▶ Run power cables separately from signal cables. Interference from
power cables can induce spurious faults on signal cables, ensure that
there is at least 100mm separation from each other.
▶ Ensure the cables are of sufficient length to allow the control box to
be moved to the service position.
If the power cable is of insufficient length, accessing the connection
terminal
Fig.
▶ Replace with the following cable types:
– H05V2V2F x 0.75 mm
2
▶ Connect the cable so that the protective conductor is longer than the
other wires.
5.5.1
Installer connections
Connect external accessories
▶ Flip down the control appliance (
▶ Open the cover.
Fig. 54 Opening the cover
Access to the electrical connections once the cover is opened.
0010023672-001
1.
1.
2.
3.
3.
4.