Key (accessories)
Worcester 2000 – 6 721 814 552 (2019/09)
10
5
Key (accessories)
5.1
Key LED
Key accessory location
▶ The Key can be located underneath the appliance on the right hand
side.
Key LED status
The LED [1] on the Key displays different states with flashing or constant
colours.
Table 4 LED status
For more information please refer to your control manual.
6
Shutdown
6.1
Setting frost protection
NOTICE:
Risk of damage to the system from frost!
The heating system can freeze up after a prolonged period (e.g. during a
power failure, switching off the power supply, faulty fuel supply, boiler
fault etc.).
▶ Ensure that the heating system is in constant use (particularly when
there is a risk of frost).
If you are leaving your property unoccupied during cold weather, please
leave your external programmer on constant and your room thermostat
set to 12 °C.
7
Clearances and ventilation information
7.1
Appliance clearances
Your installer will have provided adequate space around the appliance
for operation, safety and servicing/maintenance access.
• The following detail the necessary clearance around the appliance for
service and maintenance.
CAUTION:
Risk of damage to appliance or property
The appliance will overheat if the clearance space around the appliance
is restricted by objects.
▶ Do not restrict this space with the addition of cupboards, shelves etc.
next to or around the appliance.
▶ Do not store any combustible materials on or next to the appliance,
such as clothes, towels, paper or plastic bags.
Fig. 7
Appliance minimum clearances
Table 5 Appliance minimum clearances
Description of the LED displays
Example
Flashing red:
Fault, e.g. no communication between the Key and
appliance:
▶ Install the key again, restore the last functioning status.
Flashing yellow:
No fault, user please wait.
Flashing green:
No fault, initialisation process is running.
Constant red:
Temporary fault:
▶ Wait for normal operating condition to be resumed.
Constant yellow:
▶ Keys with touch-sensitive indicator: Press touch-
sensitive indicator on key to start pairing.
Constant green:
No fault, normal operating condition.
LED Off:
No fault, power-saving mode or appliance without power.
Minimum clearances
Description
Dimensions (mm)
X
Appliance width
400
Y
Appliance height
724
Z
Appliance depth
300
Maintenance
1
Overall clearance height
1115/1155
1)
1) Height for either 60/100 flue or 80/125 flue
2
Overall clearance depth
900
3
In front of appliance
600
4
Overall clearance width
410
5
Above the appliance
6
Either side of appliance
5
7
Below the appliance
200
8
Compartment depth
320
2)
2) Clearnace to a combustible material
9
Appliance to removable door
20
0010012940-001