Transport
11
Uni Condens 8000 F – 6720867056 (2016/10)
3.1.1
Transporting the boiler with a crane
DANGER:
Danger to life through falling load.
▶ Only use lifting ropes of the same length.
▶ Only use lifting ropes that are in perfect condition.
▶ Hook lifting tackle only into the lifting eyes provided in the gusset
plates on top of the boiler.
▶
Never hook lifting tackle into the locking lugs on the front and
back of the boiler, or into the connectors.
▶ Lift the boiler with a crane only if you are suitably qualified to operate
the crane.
▶ Never lift the boiler with a crane on its side or on end.
Never use the locking lugs (
fig. 4, [3], page 11) for lifting.
▶ Insert the hooks of the lifting tackle into the eyes in both gusset plates
of the boiler shell (
▶ Attach the lifting hook of the crane [1] to the lifting rope.
The tilt angle of the end stop must be ≤ 90 °.
Fig. 4
Lifting the boiler with a crane
[1]
Crane hook
[2]
Lifting points
[3]
Locking lugs (not suitable for lifting by crane)
[4]
Towing points for tow ropes
[5]
Contact points for lifting with a trolley jack
[6]
Base frame rail
[7]
Contact points for lifting with a forklift truck
3.1.2
Moving the boiler with a forklift truck
DANGER:
Danger to life through falling load.
▶ Distribute the boiler weight evenly across the forklift truck/pallet
truck when lifting and moving the boiler.
▶ Observe the weight of the boiler and the maximum shipping weight of
the means of transport.
▶ When transporting, secure the boiler to prevent it falling.
NOTICE:
System damage due to damaged boiler shell.
Only move the boiler with a forklift truck if the forks are long enough to
reach right under the boiler.
▶ Prior to lifting the boiler, check that the front and back panels of the
boiler are supported by the forks of the forklift truck.
▶ Pass the forks of the forklift truck through both braces on the base
frame. (
▶ Observe the dimensions of the transport apertures
(
▶ Slowly lift the boiler with the forklift truck.
Fig. 5
Moving the boiler with a forklift truck
Table 8 Dimensions of the transport apertures
1
2
3
3
4
5
5
6
7
4
90°
0010014766-001
Abbreviation
Dimensions in mm
Width
A
200
Clearance
B
700
Height
C
90
0010014765-001
A
A
B
C
Содержание Uni Condens 8000 F
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...