6 720 220 377
Subject to change without prior notice Revised 02-13
8
TsTbM-rrs--TW-a
Caution
Once in the Tech Setup Menu, the
+
button rotates through the setup
features while the
button changes the values for that particular
setting. The
+
button does not change the value and will take you to
the next feature. Only the
button will change the value.
Tech setup steps
lCD will
show
adjustment Options
factory
Default
settings
Zone
selection
Selects which zone is
used for connecting to the
TSTBM3H2CPH6W-A.
Only 1 remote can be used
for each zone for a total of 4
remotes.
Zone 1
Zone 2
Zone 3
Zone 4
The Zone number on the
TSTBM-RRS--TW-A and the
TSTBM3H2CPH6W-A must match in
order to establish a connection.
ZONE 1
remote
name
Selects a Name for the remote.
This name will appear on the
TSTBM3H2CPH6W-A when
the TSTBM3H2CPH6W-A
is displaying the remote’s
temperature.
Remote 1, Remote 2,
Remote 3, Remote 4,
Bedroom 1, Bedroom 2,
Bedroom 3, Bedroom 4,
Kitchen, Living Room, Hall, Family
Room, Dining Room, Offi ce, Study,
Den, Loft, Upstairs.
REMOTE
1
show set
Enabling this feature
will allow the remote to
temporarily override the
TSTBM3H2CPH6W-A set point.
N—The remote is used as a sensor only
and cannot change the current set
point.
Y—Enables the temperature adjustment
keys allowing the user to temporarily
override the TSTBM3H2CPH6W-A set point
with the TSTBM-RRS--TW-A remote.
N
room
Temperature
Calibration
This feature allows the
installer to change the
calibration of the room
temperature display. For
example, if the thermostat
reads 70° and you would like it
to read 72° then 2.
You can adjust the room temperature
display to read
-4°F to +4°F above or below the
factory calibrated reading.
0
f or C
This feature sets the
display temperature to
read in either Fahrenheit or
Celsius.
F for Fahrenheit
C for Celsius.
F
low
Temperature
setpoint
limit
This feature allows you
to set a minimum cool
setpoint value. The
setpoint temperature
cannot be lowered
below this value.
Use the
k
ey to select the minimum
cool setpoint.
44ºF
high
Temperature
setpoint
limit
This feature allows you to set a
maximum heat setpoint value.
The setpoint temperature
cannot be raised
above this value.
Use the
key to select the maximum
heat setpoint.
90ºF
Technician setup Menu