Product Information
7
TSS – 6720887693 (2018/10)
2.2
Product data for energy consumption
Detailed information about energy consumption can be found on our
website.
2.3
Performance data
Table 7 Calculated annual result, location: Athens
For an optimal cost/benefit ratio, we recommend solar coverage of
60-75 %.
2.4
Selecting the system
Fig. 7
Recommendation: selection of the thermosiphon system
according to daily DHW consumption
2.5
Specification
Table 8 Collector
Table 9 Memory
Table 10 Entire thermosiphon system
2.6
Intended use
The installation system is intended solely for the secure mounting of
collectors and the storage tank.
It can be used on a roof with a slope of 25 - 45°.
▶ Never modify components.
▶ Do not damage the roof or building structure.
Mount the installation system parallel to the roof, as described in these
instructions.
▶ Do not raise the installation system on-site in order to increase the
solar yields. The additional solar yields are minimal.
Permissible heat transfer medium
▶ To protect the collectors against damage through frost and corrosion,
operate them with solar heat transfer medium L
(70 % water, 30 % propylene glycol).
▶ If water is used as a heat transfer medium, the following prerequisites
must be fulfilled:
– Continuous ambient temperatures above 5 °C.
– Closed circuit. This prevents the introduction of oxygen. In the
event of a pressure drop, remedy the fault immediately.
– Have the water checked (
table).
Limits for water as a heat transfer medium:
Table 11
1)
c (HCO
3
–
) = concentration of hydrogen carbonate ions (unit: m mol/l)
c (SO
4
2–
) = concentrate of sulphate ions (unit: m mol/l)
System
Daily water consumption (litres/day)
110 l
140 l
170 l
200 l
250 l
300 l
400 l
Q
d
kWh/y annual heat demand
1270
1621
1962
2313
2891
3469
4625
Q
L
kWh/y annual system performance
TSS150
1025
1218
1367
1454
1577
1621
TSS200
1226
1384
1516
1638
1726
1787
TSS300
1454
1717
1954
2295
2593
2935
f
sol
% solar coverage
TSS150
81
75
70
63
55
47
TSS200
76
71
66
57
50
39
TSS300
90
87
84
80
75
64
FCC220-2
Certificate: CE marking,
Solar Keymark register no. 011-7S2181 F
Length
mm
2025
Width
mm
1030
Height
mm
67
Clearance between collectors
mm
69
Collector connection (in the shape of a ferrule)
mm
23
Absorber capacity (V
F
)
l
0.8
Total collector area (gross area, A
G
)
m
2
2.09
Absorber surface area (net area, A
A
)
m
2
1.92
Aperture area
(area on which the usable sunlight falls, A
a
)
m
2
1.94
Net weight excluding packaging (m
c
)
kg
30
Permissible collector operating pressure
bar
6 (600 kPa)
0010015998-01
0010015998-01
TSS150
TSS200
TSS300
45°C
110 - 170 l/d
140 - 200 l/d
TSS...
200 - 350 l/d
+
150 l 200 l 300 l
Weight, empty (m
Tank
)
kg
61
75
96
Weight, filled
kg
215
275
384
Primary circuit contents
(heat transfer medium V
F
)
l
4
5.2
7.5
Secondary circuit contents
(potable water V
W
)
l
145
195
280
Max. operating pressure,
primary circuit (p
F
)
bar
2.5 (250 kPa)
Max. operating pressure,
secondary circuit (p
W
)
bar
8 (800 kPa)
Max. temperature, primary circuit
°C
110
Max. temperature, secondary circuit
°C
95
Heat loss
W/K
1.44
1.61
2.57
Insulation
mm
50
Diameter
mm
580
Width
mm
1100 1350 1820
150
200
300
Certificate: Solar Keymark,
register no. 011-7S2816 A
Total weight, filled (approximate)
kg
290
340
510
Parameter
Value
pH value
7.5 - 9
Electrical conductivity
100 - 1500 microS/cm
Carbonate hardness and
sulphate
1)
Chloride content
maximum 30 mg/l
Содержание TSS Series
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...