9
TRZ 12-2
6 720 610 625 (01.11)
2
Installation
2.1
Fixing
B
Select fixing location (Fig. 2).
B
Pull off top part (a) of programmer
(Fig. 3).
B
Remove protective cover (a1)
(Fig. 4).
B
Fix base (b) to wall with screws
(Fig. 5).
B
Refit top part (a) of programmer.
B
Make electrical connections
(see 2.2).
B
Refit protective cover (a1)
(Fig. 4).
B
Remove insulation strip (a2) from
battery compartment (Fig. 4).
2.2
Electrical connections
Connections between TRZ 12-2 and
boiler:
B
Use electrical cable that conforms to
the rating H05 VV-... (NYM...).
Connect up the TRZ 12-2 as shown in
the wiring diagram:
Danger:
Risk of electric shock!
B
Before installation,
switch off the mains
power supply
(230 V AC).
Boiler type
Elec. connections
Boiler with
Bosch Eurotronic
KN/K..-8 E/EC
KN..-8 P/KP
1)
1) Remove jumper for intermittent pump
mode as described in KN..-8 KP installa-
tion instructions.
Boiler with
switchbox Z23
ZS/ZW 20...
EHR/EHRE 160...350
NOx HR/HRC...
Third-party brands
English