Bosch TRONIC 5000T ES30M Скачать руководство пользователя страница 10

1 0

 |

 

Installation Manual

Bosch Tronic 5000T Electric Water Heaters - BTC 724001301 A (10.2021)

7     Installation

     

WARNING: PERSONAL INJURY, PROPERTY DAMAGE

 

This water heater should be installed in accordance with all 
national, state and local codes and ordinances. If additional 
information is desired, the latest edition of the National 
Electric Code "NFPA 70" are recommended.

The above information is available from: 

National Fire Protection Agency
1 Batterymarch Park 
Quincy, MA 02269 

American National Standards Institute
1430 Broadway 
New York, NY 10018

Check with the local authorities having jurisdiction over your installation.

 

    Before proceeding with the installation, close the main water supply 

valve, open a water faucet to relieve the water pressure, and then close 
the faucet.

 

    This electric water heater is not intended for space heating applications.

7.1     Location

     

WARNING: FIRE, EXPLOSION

 

Areas where flammable liquids (gasoline, solvents, liquid 
propane, butane, etc.), or other substances which emit 
flammable vapors are stored may not be suitable for 
water heater installation. Natural air movements can carry 
flammable vapors varied distances from where they are 
stored or used. The water heater thermostat  contacts  
can arc and ignite these vapors causing property damage, 
serious burns or death. Never store or use flammable 
substances in the same room or area containing an electric 
water heater. Gasoline or other flammable substances must 
never be used in the same room or area containing a water 
heater or other spark-producing device.

This residential water heater should be installed in a clean, dry location close to 
where a good electrical connection can be made and as close to the major usage of 
hot water as possible. The unit can be installed on a combustible fl oor with 
0 inches minimum clearance to combustible walls. The heater should be located so 
that all electrical controls, heating elements, drain valve and water connections are 
accessible. Adequate clearance must be provided for the access panel. 

     

NOTICE: PROPERTY DAMAGE

 

This water heater must be located in an area where leakage 
of the tank or connections will not result in damage to 
the area adjacent to the water heater or to lower floors of 
the structure. When such locations cannot be avoided, 
a suitable drain pan must be installed under the water 
heater. Such pans must be at least 2 inches deep having a 
minimum length and width of at least 2 inches greater than 
the diameter of the water heater and should be piped to an 
adequate drain.

 

7.2     Condensation

Condensation can form on the tank when it is fi rst fi lled with water. Condensation 
might also occur with a heavy water draw and very cold inlet water temperature.
This condition is not unusual and will evaporate after the water becomes heated. If, 
however, the condensation continues, examine the piping and fi ttings for possible 
leaks.

7.3     Water Lines and  Connections

The hook-up connections will be determined by the need for hot water. 

 

The cold water line connects to the inlet nipple at the base of the water 
heater. 

 

The hot water line connects to the outlet nipple on top of the water heater. 

 

By providing unions on the water connections and a shut off valve in the 
cold water line, the water heater may be disconnected for servicing when 
necessary.

 

Two temperatures of hot water can be achieved by a mixing valve. 

 

The valves, piping, and pipe connection should be of the same type and 
manufacturer. 

 

The pipe lengths from the center line of inlets and outlets to the water 
heater must be exactly equal. 

 

All hook-ups must comply with all local codes. Install a vacuum relief anti-
siphon device on the cold water inlet line. 

 

    Do not install a check valve or other devices that would prevent reverse 

flow of water unless required by local codes because a closed system will 
result and frequent operation of the relief valve will occur.

Содержание TRONIC 5000T ES30M

Страница 1: ...roperty damage personal injury or death WARNING Installation and service must be performed by a qualified installer or service agency WARNING Improper installation adjustment alteration service or maintenance can cause injury death or property damage WARNING READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER Install or locate this water heater only in accordance with the installation instruction...

Страница 2: ...2 Installation Manual Bosch Tronic 5000T Electric Water Heaters BTC 724001301 A 10 2021 ...

Страница 3: ... Piping Installation 11 7 5 Closed System Thermal Expansion 11 7 6 Relief Valves 11 7 7 Recirculating Lines 12 7 8 Turning on Water to Heater 12 7 9 Electrical Diagrams 13 7 10 Electrical Connections 14 7 11 Thermostats and Controls 15 7 12 Installation Checklist 15 8 Water Temperature Regulation 17 9 Safety Controls 17 10 Seasonal Operation 17 11 Maintenance 18 11 1 Draining Heater 18 11 2 Test t...

Страница 4: ...for any damages resulting from failure to comply with these instructions Read these instructions thoroughly before proceeding WARNING IMPROPERORDANGEROUSOPERATION Installation and service must be performed by a qualified installer or service agency Improper installation adjustment alteration service or maintenance can cause injury death or property damage WARNING INDOORINSTALLATIONONLY DO NOT INST...

Страница 5: ...lves that may cause excessive restrictions to water flow Use full flow ball or gate valves only DO NOT use 50 50 tin lead solder or any lead based solder in potable water lines ONLY use 95 5 Tin antimony or other equivalent materials DO NOT tamper with thermostat heater elements electrical connections or temperature and pressure relief valve Tampering with any of these components is DANGEROUS and ...

Страница 6: ...attachment or use of any special attachment such as energy saving devices other than those authorized by the manufacturer into onto or in conjunction with the water heater The use of such unauthorized devices may shorten the life of the water heater and may endanger life and property The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized d...

Страница 7: ...thermostat s 3 Insulation Blanket Some governing bodies may require the use of external insulation blankets when water heaters are installed in newly constructed homes and or additions If an insulation blanket is used on this water heater CAUTION must be exercised so as to not restrict its proper function and operation Please note the following Do not cover the temperature and pressure relief valv...

Страница 8: ...0 38 0 47 0 4 500 21 0 91 24 ES50LB 46 42 0 58 0 4 500 21 0 93 24 Table 2 5 Dimensions Figure 2 A B D C HOT ANODE ROD COLD F ANODE ROD T P VALVE Dimensions in inches floor to Approx Ship Weight Lbs Recommended Drain Pan Diameter Inches ModelNumber Jacket Diameter Water Conn Top of Heater Side T P Water Spread A B C D F ES30M 18 1 4 50 48 41 3 4 8 94 5 20 ES40M 20 1 4 51 1 7 49 1 7 42 1 2 8 112 5 22...

Страница 9: ...igher can potentially cause lime scale build up Maintain water pH between 6 5 and 8 5 Check with litmus paper or have it chemically analyzed by a local water treatment company If the pH is not between 6 5 and 8 5 consult a local water treatment company for solutions Water Hardness Water hardness levels above the upper limit of 7 grains gallon 120 mg L can lead to lime scale build up throughout the...

Страница 10: ...e heater should be located so that all electrical controls heating elements drain valve and water connections are accessible Adequate clearance must be provided for the access panel NOTICE PROPERTYDAMAGE This water heater must be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the water heater or to lower floors of the structure When su...

Страница 11: ...t required by local codes and no less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meets the requirements for Relief Valves and Automatic Gas Shut off Devices for Hot Water Supply Systems ANSI Z2 I 22 This valve must be marked with a maximum set pre...

Страница 12: ...an Figure 3 Manual Relief Level Temperature Pressure Relief Valve Discharge Line to Drain Discharge Line WARNING SCALDHAZARD PROPERTYDAMAGE Discharging water may be hot and can cause scald injuries and property damage Discharge lines must be properly installed and piped to an adequate drain The discharge line Must not be smaller than the pipe size of the relief valve Must not be capped blocked plu...

Страница 13: ...ections Figure 5 TotalWaterHeater Wattage Phases Recommended Over Current Protection Fuse or Circuit Breaker Amperage Rating Copper Wire Size AWG Based on N E C Table 310 16 75 C 240V 240V 4 500 1 25 10 Table 4 WARNING HAZARDOUSVOLTAGE If wiring from your fuse box or circuit breaker box was aluminium for your old water heater replace it with copper wire If you wish to reuse the existing aluminium ...

Страница 14: ...c unions flexible connectors etc can cause the water heater to be electrically isolated NOTICE PRODUCTDAMAGE Before closing the switch to allow the electric current to flow to the water heater make certain that the water heater is completely full of water and that the cold water inlet valve is open If the heating elements are not completely immersed in water at all times they will be damaged if ener...

Страница 15: ...risk of scald injury WARNING SCALDHAZARD Never allow small children to use a hot water tap or to draw their own bath water Never leave a child or handicapped person unattended in a bathtub or shower Increasing the thermostat setting above the pre set temperature may consume excessive energy and also might cause the high limit to shut off power to the water heater under certain operating conditions ...

Страница 16: ...ual Bosch Tronic 5000T Electric Water Heaters BTC 724001301 A 10 2021 Figure 6 HOT COLD TEMPERATURE PRESSURE RELIEF VALVE DISCHARGE PIPE DO NOT CAP OR PLUG 6 AIR GAP SHUT OFF VALVE SUITABLE OPEN DRAIN Installation Example ...

Страница 17: ...panel s Turn on the power to the water heater Water temperature ranges of 120 140 F recommended by most dishwasher manufacturers 9 Safety Controls The water heater is equipped with combination thermostat and temperature limiting controls ECO that are located above the heating element in contact with the tank surface If for any reason the water temperature becomes excessively high the temperature l...

Страница 18: ...re reenergizing Drain a few quarts of water to flush out accumulated sediment after the first 6 months then annually thereafter Foreign material can wash in and unless the water supply is naturally soft 0 to 5 grains hardness scale or lime deposits will accumulate in the tank Hard water scale precipitates at an increasingly high rate in proportion to an increase in water temperature Failure of the t...

Страница 19: ...annually or more frequently if needed If you use a water softener your anode rod will deplete faster than normal and as such would need more frequent inspection NOTICE WARRANTYEXCLUSION Damages or malfunction caused by lack of anode maintenance are not covered by the warranty Figure 10 New Anode Rod Partially Depleted Anode Completely Depleted Anode To inspect or replace the anode rod put a hose t...

Страница 20: ...asket on element Place element into opening and tighten securely Then follow Filling the Water Heater instructions in the Installation Instructions section F Water from drain valve may be due to the valve being opened slightly G The drain valve may be leaking from the tank fitting H Water in the water heater bottom or on the floor may be from condensation loose connections or the temperature pressur...

Страница 21: ...fter a large hot water demand A fuse is blown or a circuit breaker tripped Replace fuse or reset circuit breaker Electric supply may be off Make sure electric supply to water heater and disconnect switch if used are in the ON position The thermostat may be set too low See the Temperature regulation of the water heater section of this manual Leaking or open hot water faucets Make sure all faucets ar...

Страница 22: ...22 Installation Manual Bosch Tronic 5000T Electric Water Heaters BTC 724001301 A 10 2021 13 Water Heater Components Figure 12 ...

Страница 23: ... 23 Installation Manual Bosch Tronic 5000T Electric Water Heaters BTC 724001301 A 10 2021 ...

Страница 24: ...ogy Corp 65 Grove St Watertown MA 02472 Tel 866 642 3198 www bosch thermotechnology us BTC 724001301 A 10 2021 Bosch Thermotechnology Corp reserves the right to make changes without notice due to continuing engineering and technological advances ...